Skip to main content
OpenTrials
Completed

NCT Number: NCT05861388

Bio-HPP vs Cast Co-cr as Implant Framework

The purpose of this study was to assess the effect of Bio-Hpp versus Co-Cr custom abutments in fixed-detachable implant-supported mandibular partial dentures clinically and radiographically in Class I Kennedy classification (split-mouth study)

Completed

Looking for future studies?

Notify Me

Key information

Age range

40 year–55 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

About this study

Participants with bilateral partial edentulism in the posterior mandible received two implants at the positions of the second premolar and second molar on both sides; one side was restored with BioHpp based screw-retained FDP (test group) and the other side was restored with Co-Cr based screw-retained FDP (control group). All patients were clinically examined at the time of prosthesis insertion, and 6,12 months later for fracture of implant or framework, fracture, or looseness of the screw, veneer chipping, and fractures, modified bleeding index, modified plaque index, peri-implant probing depth, as well as radiographically for marginal bone loss

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Mandibular posterior edentulous with the first premolar as the last standing abutment tooth bilaterally.
  • All patients were edentulous for at least 6 months from the last extraction.
  • The bone height of the alveolar ridge was not less than 12 mm above the inferior alveolar canal and the buccolingual width of the alveolar ridge at the prospective implant site was not less than 6 mm.
  • The opposing arch was almost dentulous, and any missing teeth were restored using a fixed partial denture.
  • Adequate interarch space at least 5mm between the opposing dentition and the mandibular edentulous space.
  • Remaining teeth were in good periodontal condition.
  • Maintaining good oral hygiene and were ready to cooperate throughout the study.

Exclusion criteria

  • Patients with active infection or inflammation or flabby tissue in the areas intended for implant placement.
  • Those patients with systemic diseases that may influence soft or hard tissue healing.
  • Patients with a history of radiation therapy in the head and neck region.
  • Neurological or psychiatric handicap patients that could interfere with good oral hygiene.
  • Heavy smokers and drug abusers.
  • Patients with severe clenching or bruxism.

Treatment and study plan

implant placement

Procedure

2 implants were placed at position of lower 2nd premolar and 2nd molar

Other names: final prosthesis was constructed on the implants

Primary outcomes

  1. marginal bone loss around implants

    Time frame: 12 months

    Marginal bone level was measured from the implant shoulder to the first bone to implant contact on the mesial and distal sides of the implant on digital standardized periapical radiograph using the long cone paralleling technique

  2. modified plaque index

    Time frame: 12 months

    Plaque adherent to the implants was quantified at four surfaces: buccal, lingual, mesial, and distal using a plastic periodontal probe after air drying for the implant and gingiva. The four sides for each implant were scored 0-3 according to the following criteria:

    Score 0: No plaque detected. Score 1: Plaque can be detected by running a probe across the marginal surface of the implant.

    Score 2: Plaque can be seen by naked eye. Score 3: Abundance of plaque.

  3. modified bleeding index

    Time frame: 12 months

    A plastic periodontal probe was passed along the gingival margin adjacent to the implant and the following scores were given according to Mombelli and Lang Score 0: No bleeding with slight pressure on the mucosa using periodontal probe.

    Score 1: Isolated bleeding spots visible. Score 2: Blood forms a confluent red line on margin. Score 3: Heavy or profuse bleeding

  4. probing depth

    Time frame: 12 months

    ., the peri- implant probing pocket depth is measured around the surfaces of the implants in four areas (mid-buccal, mid-lingual, med-mesial, mid-distal) using plastic periodontal probe* which was inserted with light force and parallel to long axis of implant

Secondary outcomes

  1. mechanical complications

    Time frame: 12 months after loading

    framework fracture, screw loosening, screw fracture and chipping or fracture of veneer layer

Sponsors and collaborators

Lead sponsor

Tanta University

Other

Registry information

Official study title

Short Term Comparative Evaluation of Bio-HPP and Cast Cobalt-chromium as a Framework for Implant-supported Prostheses: A Split-mouth Clinical Randomized Study

Important dates

Study start
2017
Primary completion
2019
Study completion
2020
First posted
May 16, 2023
Registry last updated
May 16, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.