stenfilcon A toric lens
Devicetoric contact lens
NCT Number: NCT02410824
Bilateral dispensing clinical trial of stenfilcon A against etafilcon A for astigmatism.
Looking for future studies?
Notify Me17 year and older
All sexes
Interventional
Not applicable
Center for Contact Lens Research, University of Waterloo, Waterloo, Ontario, Canada
CooperVision is evaluating the clinical performance of an FDA cleared silicone-hydrogel lens material stenfilcon A (test) compared to etafilcon A for Astigmatism lens (control) when worn on a daily wear basis over one (1) week in a randomized, bilateral, cross-over, dispensing study.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
toric contact lens
toric contact lens
Time frame: Baseline and 1 Week
Subjective ratings of lens performance for comfort assessed at baseline and 1 week. Comfort Scale 0-100, 0=extremely uncomfortable/cannot tolerate, 100=extremely comfortable/cannot be felt.
Time frame: Baseline and 1 Week
Subjective ratings of lens performance for handling assessed at baseline and 1 week. Handling Scale 0-100, 0=very difficult to handle, 100=very easy to handle.
Time frame: Baseline and 1 Week
Subjective ratings of lens performance for vision assessed at baseline and 1 week. Scale 0-100, 0=extremely poor vision all of the time, cannot function, 100=excellent.
Time frame: Baseline and 1 Week
High illumination high contrast (HIHC) visual acuity for stenfilcon A toric lens and etafilcon A toric lens assessed at baseline and 1 week. Visual acuity is measured by logMAR.
Time frame: Baseline and 1 Week
Low illumination high contrast (LIHC) visual acuity for stenfilcon A toric lens and etafilcon A toric lens assessed at baseline and 1 week. Visual acuity is measured by logMAR.
Time frame: Baseline and 1 Week
Lens surface of wettability for stenfilcon A toric lens and etafilcon A toric lens assessed at baseline and 1 week. Scale 0-4, 0=severely reduced, 4=excellent wettability.
Time frame: Baseline and 1 Week
Lens surface of wettability for stenfilcon A toric lens and etafilcon A toric lens assessed at baseline and 1 week. Scale 0-4, 0=no deposits, 4=severe deposits.
Time frame: Baseline and 1 week
Ocular health of corneal staining, type for stenfilcon A toric lens and etafilcon A toric lens assessed at baseline and 1 week. Scale 0-4, 0=No staining, 4=Severe staining Five quadrants: C - Central, N - Nasal, T - Temporal, S - Superior, I - Inferior
Time frame: Baseline and 1 week
Ocular health of corneal staining (extent) for stenfilcon A toric lens and etafilcon A toric lens assessed at baseline and 1 week. Scale 0-4, 0=No staining 1=1-15% of area 2=16-30% of area 3=31-45% of area 4=>45% of area Five quadrants: C - Central, N - Nasal, T - Temporal, S - Superior, I - Inferior
Time frame: Baseline and 1 week
Ocular health of conjunctival staining for stenfilcon A toric lens and etafilcon A toric lens assessed at baseline and 1 week. Measured in 0.50 steps, scale 0-4, 0=None, 1=Minimal diffuse punctate, 2=Coalescent punctate, 3=Confluent, 4= Deep confluent
N - Nasal, T - Temporal, S - Superior, I - Inferior
Time frame: 1 Week
Lens durability (lens tearing) between stenfilcon A toric lens or etafilcon A toric lens assessed at 1 week. (The number of lens tear or lens nicks found during the one week study).
Time frame: Baseline and 1 Week
Lens fit acceptance (on eye stability) for stenfilcon A and etafilcon A assessed at baseline and 1 week. Scale 0-4, 0=Can't be worn, 1=Poor, 2=Fair, 3=Good, 4=optimum.
Time frame: 1 Week
Subjective ratings of lens performance for dryness assessed during the day and at the end of the day. Scale 0-100, 0=cannot be worn, extremely dry, 100=no dryness experienced at any time.
Time frame: Baseline and 1 week
Overall satisfaction of stenfilcon A and etafilcon A lenses. Scale 0-100, 0=extremely dissatisfied, 100=extremely satisfied.
CooperVision, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06775509
Astigmatism, Eye Diseases
Tarragona, Spain
View Trial DetailsNCT06784063
Astigmatism, Cataract
Bloomfield Hills, Michigan, United States
View Trial DetailsNCT06749496
Astigmatism, Eye Diseases
Jacksonville, Florida, United States
View Trial DetailsNCT06967129
Astigmatism, Eye Diseases
Mission Viejo, California, United States
View Trial Details