NCT Number: NCT00607321

Bare Metal Bifurcation Stent Clinical Trial in Humans

To assess the feasibility and safety of the Medtronic Bifurcation Stent System for the treatment of single de novo bifurcation lesions in native coronary arteries with reference vessel diameters (RVD) for the proximal main vessel of 3.8 - 4.3 mm, distal main branch of 3.0 - 3.5 mm, and side branch RVD up to 2.5 mm.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Auckland City Hospital

Auckland, New Zealand

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

General Inclusion Criteria

  • Candidate for percutaneous coronary intervention & emergent coronary artery bypass graft surgery
  • Clinical evidence of ischemic heart disease or a positive functional study
  • Female patients of childbearing potential has negative pregnancy test within 7 days before trial procedure
  • Patient or patient's legal representative provided written informed consent
  • Patient agrees to comply with follow-up evaluations

Angiographic Inclusion Criteria

  • Target lesion ia a single de novo bifurcation lesion involving a native coronary artery with reference vessel diameter for the proximal main of 3.8 - 4.3 mm, distal main of 3.0 - 3.5 mm, & side branch RVD up to 2.5 mm
  • Acceptable target lesion lengths are any combination of:
  • <16mm proximally from carina in proximal main vessel
  • <16mm distally from the carina in distal main branch
  • <12mm from carina in side branch
  • Target lesion in main vessel has stenosis of > 50% and <100%
  • Target vessel has (TIMI) flow >2

General Exclusion Criteria

  • Known hypersensitivity/contraindication to aspirin, heparin or bivalirudin, clopidogrel or ticlopidine, cobalt, nickel, chromium, molybdenum, or sensitivity to contrast media, which can't be adequately pre-medicated
  • Platelet count <100,000 cells/mm³ or >700,000 cells/mm³, or a white blood cell (WBC) count <3,000 cells/mm³ within 7 days prior to index procedure
  • Serum creatinine level >170 micromol/L within 7 days prior to index procedure
  • Evidence of acute MI within 72 hours of intended trial procedure (defined as: QWMI or NQWMI having CK enzymes >2X laboratory upper limit of normal with presence of elevated CK-MB (any amount above laboratory upper limit of normal)
  • Previous stenting anywhere in target vessel
  • PCI of non-target vessel within 30 days prior to procedure that results in any MACE event. If non target vessel stent is implanted within 72 hours prior to index procedure, 2 post procedural serial CK or CK-MB measurements must be below investigational site's upper limit of normal.
  • PCI of non-target vessel within 24 hours prior to procedure
  • Planned PCI of any vessel within 30 days post-procedure
  • Planned PCI of the target vessel within 6 months post-procedure
  • During index procedure, target lesion requires treatment with device other than PTCA or cutting balloon prior to stent placement
  • Documented left ventricular ejection fraction (LVEF) <30% at most recent evaluation.
  • History of stroke or transient ischemic attack (TIA) within prior 6 months
  • Active peptic ulcer or upper gastrointestinal (GI) bleeding within prior 6 months
  • History of bleeding diathesis or coagulopathy or will refuse blood transfusions
  • Concurrent medical condition with life expectancy < 12 months
  • Currently participating in investigational drug or device trial that's not completed the primary endpoint or that clinically interferes with current trial endpoints; or requires coronary angiography, IVUS or other coronary artery imaging procedures.

Angiographic Exclusion Criteria

  • Bifurcation angle of >90 degrees by visual estimate
  • Target lesion located in native vessel with saphenous vein graft or left/right internal mammary artery (LIMA/RIMA) bypass
  • Significant stenosis (>50%) proximal or distal to target lesion that might require revascularization or impede run off.
  • Target vessel is excessively tortuous (two bends >90º to reach target lesion)
  • Target lesion has any of following characteristics:
  • Lesion location is aorto-ostial, unprotected left main lesion, or within 5 mm of origin of left anterior descending (LAD), left circumflex (LCX), or right coronary artery (RCA).
  • Severely calcified
  • Evidence of thrombus
  • Co-existence of unprotected left main coronary artery disease (obstruction >50% in left main coronary artery)

Treatment and study plan

Medtronic Bifurcation Stent System

Device

Percutaneous Coronary Stenting

Primary outcomes

  1. Number of Participants With Target Vessel Failure (TVF) at 30 Days Post Procedure.

    Time frame: 30 days

    TVF was reported if any of the following events occurred: Recurrent MI in territory not clearly attributed to a vessel other than the target lesion; Cardiac death not clearly due to a non-target vessel endpoint or Clinically driven target revascularization.

Secondary outcomes

  1. Device Success

    Time frame: During index procedure

    Device success is reported as Historical-standard definition: attainment of <50% residual stenosis of all target lesion/s using only the assigned device and any adjunct stents as specified in the Investigational Plan.

  2. Number of Participants With Target Vessel Failure (TVF) at 6 Months

    Time frame: 6 month

    TVF was reported if any of the following events occurred: Recurrent MI in territory not clearly attributed to a vessel other than the target lesion; Cardiac death not clearly due to a non-target vessel endpoint or Clinically driven target revascularization.

  3. Number of Participants With Target Vessel Failure at 9 Months.

    Time frame: 9 month

    TVF was reported if any of the following events occurred: Recurrent MI in territory not clearly attributed to a vessel other than the target lesion; Cardiac death not clearly due to a non-target vessel endpoint or Clinically driven target revascularization.

  4. Number of Participant With Target Vessel Failure at 12 Months

    Time frame: 12 month

    TVF was reported if any of the following events occurred: Recurrent MI in territory not clearly attributed to a vessel other than the target lesion; Cardiac death not clearly due to a non-target vessel endpoint or Clinically driven target revascularization.

Sponsors and collaborators

Lead sponsor

Medtronic Vascular

Industry

Registry information

Official study title

The Medtronic Bare Metal Bifurcation Stent Clinical Trial in Humans

Acronym: BRANCH

Important dates

Study start
2008
Primary completion
2010
Study completion
2010
First posted
Feb 5, 2008
Registry last updated
May 18, 2017

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.