Rouen University Hospital
Rouen, France
NCT Number: NCT02231827
Gait and balance disorders are important public health problem necessitating studies to try to prevent falls. Many studies have dealt with spatiotemporal gait parameters or balance during quiet standing (posturography). Nevertheless, falls occurred predominantly during gait, and rarely during quiet standing. We have developed a tool to measure balance during gait : the braking of the center of mass (CM), a biomechanical parameter obtained from the vertical velocity of the CM recorded with a force plate.
In previous studies, we have shown that the braking of the CM was a physiological and a active mechanism, reflecting balance during gait. Unfortunately, the braking of the CM measured on a force plate provide an important intra-individual variability.
The 3D optoelectronic gait analysis system (VICON) also provide an estimation of the CM. The primary goal of this study is to compare intra-individual variability of the braking of the CM determined by a force plate or the 3D optoelectronic gait analysis system (VICON) in healthy subjects.
Looking for future studies?
Notify Me20 year–40 year
All sexes
Interventional
Not applicable
Rouen, France
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Subjects, barefoot and standing upright and motionless on a force plate, were instructed to walk for 10 m following a beep delivered by the experimenter. Two experimental conditions were tested: (i) the 'natural' gait condition where subjects walked normally and (ii) the 'fast' gait condition where subjects walked as fast as they could, taking large steps. Each subject performed 10 trials in each condition.
Other names: - Force plate, - 3D optoelectronic gait analysis system (VICON)
Time frame: 1 day
Braking of the center of mass (CM), a biomechanical parameter obtained from the vertical velocity of the CM, determined by a force plate or a 3D optoelectronic gait analysis system (VICON).
Time frame: 1 day
Braking of the center of mass (CM), a biomechanical parameter obtained from the vertical velocity of the CM, determined by a 3D optoelectronic gait analysis system (VICON).
University Hospital, Rouen
Other
A Study of the Balance Control During Gait : Comparison of Data Acquisition Between Force Plate and 3D Optoelectronic Gait Analysis System
Acronym: FREINAGE3D
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT06702423
Healthy
London, United Kingdom
View Trial DetailsNCT07223164
Healthy
Irvine, California, United States
View Trial DetailsNCT05595902
Healthy
Kadıköy, Istanbul, Turkey (Türkiye)
View Trial Details