Medtronic Avalus Ultra
DeviceSurgical aortic valve replacement with the Medtronic Avalus Ultra bioprosthesis for management of aortic stenosis and regurgitation.
NCT Number: NCT06506903
The purpose of this study is to characterize the safety and effectiveness of the Medtronic Avalus Ultra aortic valve bioprosthesis in patients with aortic valve disease.
This study is active but is not currently recruiting participants.
Notify Me18 year and older
All sexes
Interventional
Not applicable
Hartford Hospital, Hartford, Connecticut, United States
A prospective, multi-center, single-arm, interventional, non-randomized, post-market study to characterize the safety and effectiveness of the Medtronic Avalus Ultra aortic valve bioprosthesis in patients with aortic valve disease. Approximately 150 subjects in the United States will be implanted and followed through one year post-procedure.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Subjects must meet the following criteria to be included in the study:
Exclusion criteria
Subjects who meet any of the following criteria will not be eligible for participation in the study:
Surgical aortic valve replacement with the Medtronic Avalus Ultra bioprosthesis for management of aortic stenosis and regurgitation.
Time frame: 30 days and 1 year post-procedure
Safety of the valve is evaluated by the time-related incidence of valve-related adverse events and death. The following valve-related adverse events are evaluated in this study: thromboembolism, valve thrombosis, hemorrhage, paravalvular leak, endocarditis, structural valve deterioration, non-structural valve dysfunction, reintervention, death. This safety endpoint is descriptive, and no statistical hypothesis testing will be performed. The primary analysis of safety endpoint events will occur once all implanted participants have completed their 1 year post-procedure visit or exited the study.
Time frame: 30 days and 1 year post-procedure
Mean pressure gradient is evaluated by transthoracic echocardiography technique as the average flow of blood through the aortic valve measured in millimeters of mercury. This effectiveness endpoint is descriptive, and will be summarized as with continuous data. No statistical hypothesis testing will be performed. The primary analysis of effectiveness endpoint events will occur once all implanted participants have completed their 1 year post-procedure visit or exited.
Time frame: 30 days and 1 year post-procedure
Effective Orifice Area (EOA) is assessed by transthoracic echocardiography technique and is measured as the minimal cross-sectional area of the blood flow downstream of the aortic valve. This effectiveness endpoint is descriptive, and will be summarized as with continuous data. No statistical hypothesis testing will be performed. The primary analysis of effectiveness endpoint events will occur once all implanted participants have completed their 1 year post-procedure visit or exited.
Time frame: 30 days and 1 year post-procedure
The change of the New York Heart Association (NYHA) functional classification at 30 days and 1 year from baseline will be used to evaluate the change heart failure status. The primary analysis will occur once all implanted participants have completed their 1 year visit or exited; no statistical hypothesis testing will be performed.
Measure Description: Cardiac Disease with Functional Classes (lower value is more desirable than higher value) I - No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation or shortness of breath.
II - Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, shortness of breath or chest pain.
III - Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, shortness of breath or chest pain.
IV - Symptoms of heart failure at rest. Any physical activity causes further discomfort.
Time frame: 1 year post-procedure
This effectiveness endpoint is descriptive, and no statistical hypothesis testing will be performed. The primary analysis of effectiveness endpoint events will occur once all implanted participants have completed their 1 year post-procedure visit or exited.
Time frame: 1 year post-procedure
This effectiveness endpoint is descriptive, and no statistical hypothesis testing will be performed. The primary analysis of effectiveness endpoint events will occur once all implanted participants have completed their 1 year post-procedure visit or exited.
Medtronic Cardiac Surgery
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06594705
Aortic Insufficiency, Aortic Regurgitation
Los Angeles, California, United States
View Trial DetailsNCT04149600
Aneurysm, Aortic Aneurysm
Boston, Massachusetts, United States
View Trial DetailsNCT06510855
Aortic Valve Calcification, Aortic Valve Disease
Copenhagen, Capital Region of Denmark, Denmark
View Trial DetailsNCT03924661
Aortic Valve Disease, Cardiovascular Diseases
Los Angeles, California, United States
View Trial Details