Automatic Abdominal Aortic Aneurysm Diameter Measurement

Managing abdominal aortic aneurysms currently relies on diameter assessment with ultrasound. Diameter reproducibility with two-dimensional ultrasound is challenging, and requires experienced operators. A novel automatic three-dimensional ultrasound system has the potential to facilitate more precise diameter measurements than two-dimensional ultrasound. This study aimed to assess the variance of abdominal aortic aneurysm diameter measurements among ultrasound novices and experts by comparing two-dimensional ultrasound with the three-dimensional ultrasound system in a clinical setting.

Ten patients under abdominal aortic aneurysm surveillance were examined by 29 ultrasound-operators: 13 experts and 16 novices. The experts were sonographers and physicians highly experienced in abdominal aortic aneurysm ultrasound, and the novices were medical students and junior residents with sparse ultrasound experience.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Observational

Primary location

Department of Vascular Surgery, Rigshospitalet

Copenhagen, 2300, Denmark

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

-Patients with an abdominal aortic aneurysm > 3 cm.

Treatment and study plan

Philips EPIQ-7, Philips Healthcare, Bothell, WA, USA

Device

All patients had their abdominal aortic aneurysm maximum anterior-posterior diameter estimated with two-dimensional ultrasound using a 5 MHz curved array transducer (Philips® C5-1 transducer, Philips Healthcare, Bothell, WA, USA).

After the acquisition, a three-dimensional ultrasound acquisition was performed with a 3D-matrix transducer (Philips® X6-1 transducers, Philips Healthcare, Bothell, WA, USA).

Primary outcomes

  1. Abdominal aortic aneurysm measurement variance between novices and experts

    Time frame: One week

    The primary outcome was to test the variance of abdominal aortic aneurysm diameter measurements by comparing expert and novice ultrasound operators using conventional 2D-ultrasound and 3D-software assisted ultrasound.

Sponsors and collaborators

Lead sponsor

Natasha Monzon Svendsen

Other

Collaborators

  • Philips Healthcare

Registry information

Official study title

Automated Three-dimensional Ultrasound Bridges the Gap Between Novices and Experts in Diameter Assessment of Abdominal Aortic Aneurysms

Important dates

Study start
2022
Primary completion
2022
Study completion
2022
First posted
Aug 9, 2023
Registry last updated
Sep 5, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.