Dr Edward Jude
Manchester, OL6 9RW, United Kingdom
NCT Number: NCT04732208
The prevalence of diabetic retinopathy (DR) in the UK is on the rise. Within 20 years of diabetes diagnosis, nearly all people with type 1 and almost two thirds of people with type 2 diabetes (60%) have some degree of DR. NHS guidelines mandate annual DR screening in all patients aged 12 and above to prevent complications of DR. Screening for DR in England involves labour-intensive manual grading of retinal images through the teleophthalmology platform. Automated retinal image analysis systems with the use of artificial intelligence (AI) may offer an alternative to manual grading.
The purpose of this study is to evaluate the performance of a portable, hand-held fundus camera with integrated artificial intelligence for diabetic retinopathy screening by comparing it against the current standard i.e diagnosis provided by trained human graders evaluating the standard photographs/ophthalmologists.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Manchester, OL6 9RW, United Kingdom
Study will enroll diabetic patients (new and established) meeting the inclusion criteria and who would provide an informed consent to participate in the study. This would include subjects who visit the endocrinology clinic and had either their retina evaluated by a teleophthalmology consult or visited the ophthalmology clinic for an indirect ophthalmoscopic fundus evaluation in the past 3 months. Subjects whose fundus has been recently evaluated in the past 3 months will also be re-called to the endocrinology clinic to get a fundus image captured on the Remidio NM FOP-10 device. Images will be captured by an operator who will be provided training in using the device prior to the study.
Non-mydriatic fundus images are captured using a pre-defined imaging protocol. One disc centered and one macula centred 45 deg image is taken for each eye. The images are then submitted to an AI system for analysis that runs locally on the Remidio FOP. An initial image quality assessment is performed by the AI. If the image is of sufficient quality then the AI will give an output of either 'signs of DR detected' (that would include moderate NPDR, severe NPDR, PDR and/or DME present) or no signs of diabetic retinopathy detected (that would include no DR, mild DR, absence of DME). If the image is of insufficient quality, then the operator makes 2 more attempts using the same imaging protocol. The images that are output as insufficient quality will be noted. All subjects who have provided consent for dilation are then instilled with a single drop of 1% tropicamide solution. After 20 mins, mydriatic 2 field (one disc centered and one macula centered) fundus images are captured and submitted to the AI for analysis along the same lines of non-mydriatic imaging. If the image is of insufficient quality then the operator makes 2 more attempts using the same imaging protocol. The images that are output as insufficient quality will be noted.
De-identified patient data including age, gender, ethnicity and lens status (Cataract grade, pseudophakia, aphakia) along with the final diagnosis made by a certified grader/ophthalmologist during clinical examination/teleophthalmology are retrieved from the NHS database. This DR diagnosis will act as a reference standard against which the AI output will be compared.
Data entry of subjects will be performed by approved trained Site Personnel. The de-identified data is stored onto an electronic data capture system (EDC). Approved Site Personnel will have a user specific log-in name and password to access the electronic data capture (EDC) system in order to enter study data. The principal investigator will ensure that all aspects of the study are complied with. The study will be conducted in accordance with applicable regulatory requirements and established rules for Good Clinical Practice (GCP).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Fundus images will be captured before and after administration of mydriatic agent
Other names: Instillation of mydriatic eye drops
Time frame: 4 months
Time frame: 4 months
Time frame: 4 months
Time frame: 4 months
Tameside General Hospital
Other
Validation of an Artificial Intelligence Model for Diabetic Retinopathy Screening Using a Smartphone-based Fundus Camera in the UK Population
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07707856
Cardiovascular Diseases, Diabetes Complications
Banhā, Benha, Egypt
View Trial DetailsNCT04132401
Age-Related Macular Degeneration, Cardiovascular Diseases
Manresa, Barcelona, Spain
View Trial DetailsNCT04505566
Cardiovascular Diseases, Diabetes Complications
Nashville, Tennessee, United States
View Trial DetailsNCT07255326
Autoimmune Diseases, Cardiovascular Diseases
Faisalabad, Punjab Province, Pakistan
View Trial Details