Completed

NCT Number: NCT04016662

Automated Insulin Delivery in Elderly With Type 1 Diabetes (AIDE T1D)

A multi-center, randomized, crossover trial consisting of three sequential 12-week periods, with the HCL feature used during one period, the PLGS feature used during one period and SAP therapy (control) during one period. The crossover trial will be preceded by a run-in phase in which participants will receive training using the study devices (Dexcom G6 and Tandem t:slim X2 pump). After the last crossover period, participants will be given the opportunity to use study devices for an additional 12 weeks to assess preference of system use (PLGS, HCL or SAP) and associated characteristics, durability and safety in a more real-world setting with less frequent study contact.

Completed

Looking for future studies?

Notify Me

Key information

Age range

65 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 4

Primary location

AdventHealth Diabetes Institute, Orlando, Florida, United States

Loading trial locations.

About this study

Automated insulin delivery (AID) technologies hold the promise of optimizing glycemic control and reducing the burden of diabetes care for patients with Type 1 Diabetes (T1D). However, clinical trials of lower burden AID technologies have not included older adults in sufficient numbers to allow for focused evaluation of efficacy and quality of life (QOL) impacts that may differ from those observed in younger age groups. Most notably, primary endpoints have focused on reducing hyperglycemia, while avoidance of hypoglycemia is of upmost concern for older adults with T1D. T1D Exchange clinic registry data have shown severe hypoglycemia (SH) occurs more commonly in older adults with longstanding T1D than in younger individuals with events occurring just as often with HbA1c levels >8.0% as with HbA1c levels <7.0%. These data do not support the strategy of "raising the HbA1c" as being an effective approach for hypoglycemia prevention in older adults with T1D. In addition to acutely altered mental status, hypoglycemia is associated with an increased risk for falls leading to fractures, car accidents, emergency room (ER) visits, hospitalizations, and mortality resulting in substantial societal costs. The occurrence of hypoglycemia, hypoglycemia unawareness and fear of hypoglycemia have adverse effects on overall QOL of both individuals with T1D and their families.

While continuous glucose monitoring (CGM) technology alone has the potential to be beneficial in reducing hypoglycemia in older patients, our preliminary data from the Wireless Innovations for Seniors with Diabetes Mellitus (WISDM) trial shows a majority of patients still have frequent hypoglycemia even when using CGM. Thus, knowledge of CGM alone may not be sufficient to avoid hypoglycemia in this population. Predictive low-glucose suspend algorithms have particular promise when the primary goal is hypoglycemia avoidance rather than glucose reduction. Whether the added complexity of closed loop systems provides additional glycemic benefit is not known. There is a critical need to determine whether automated insulin delivery can reduce hypoglycemia in the older adult population with T1D.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Clinical diagnosis of type 1 diabetes
  • Age ≥ 65 years old
  • T1D Duration of at least 1 year
  • HbA1c < 10.0% from point of care or local lab within the past 6 months
  • Insulin regimen involves basal/bolus insulin via insulin pump or multiple daily injections
  • Most recent GFR ≥ 30 ml/min/m^2 from local lab within the past 6 months
  • Willingness to use a rapid acting insulin compatible with the Tandem t:slim X2 pump (currently aspart and lispro; other rapid acting insulins likely to be approved for pump use prior to study initiation such as Fiasp)
  • Familiarity with and willingness to use a carbohydrate ratio for meal boluses
  • Willing to use study devices and automated insulin delivery features
  • Ability to download study devices at home or if not able to download at home willing to come into clinic to bring devices for download of data at visits and as needed for safety
  • Participant is independently managing his/her diabetes with respect to insulin administration and glucose monitoring (may include assistance from spouse or other caregiver)
  • Participant understands the study protocol, agrees to comply with it and is able to successfully pass the consent understanding assessment with no more than 2 attempts
  • Participant comprehends written and spoken English
  • At least 240 hours of CGM readings available during the end of run-in assessment
  • At least 1.5% of time with CGM glucose levels < 70 mg/dL prior to SAP initiation
  • Active prescription for glucagon and willing and able to have glucagon available

Exclusion criteria

  • Use of PLGS technology or HCL insulin delivery in the past 1 month
  • History of 1 or more Diabetic Ketoacidosis episodes in the previous 6 months
  • Clinical diagnosis by a primary care provider, neurologist or psychiatrist of dementia, in the investigator's opinion a suspected severe cognitive impairment such that it would preclude ability to understand the study or use devices, or a score of 6 or less out of 15 on the 5 min MoCA (5-min T MoCA Version 2.1) (mild cognitive impairment is not an exclusion)
  • A condition, which in the opinion of the investigator or designee, would put the participant or study at risk, including severe vision or hearing impairment and any contraindication to the use of any of the study devices per FDA labeling
  • Known adhesive allergy or skin reaction during the run-in pre-randomization phase or previous difficulty with pump and CGM insertions that would preclude participation in the randomized trial
  • Concurrent use of any non-insulin glucose-lowering agent other than metformin (including GLP-1 agonists, Symlin, DPP-4 inhibitors, SGLT-2 inhibitors, sulfonylureas)
  • Stage 4 or 5 renal disease
  • The presence of a significant medical or psychiatric condition or use of a medication that in the judgment of the investigator may affect completion of any aspect of the protocol, or is likely to be associated with life expectancy of <1 year

Treatment and study plan

Tandem t:slim X2 with HCL or PLGS

Device

The system components include the t:slim X2 with Control-IQ Technology and the Dexcom CGM G6. The modular control algorithm has a safety supervision module that limits insulin delivery to prevent hypoglycemia at all times. The algorithm gradually decreases hyperglycemia from bedtime to reach a target of 120 mg/dL by waking time. During awake hours, the control algorithm attempts to maintain glucose within a target range (112.5 to 160 mg/dL) with meal time insulin boluses delivered based on usual bolus procedures undertaken by patients on an insulin pump (Hybrid closed loop).

The system components include the t:slim X2 with with Basal-IQ Technology and the Dexcom CGM G6. The PLGS System is able to stop and resume basal insulin delivery automatically in response to predicted or low sensor glucose values, thereby reducing the incidence and duration of hypoglycemic episodes. The pump includes the hypoglycemia minimization strategy that will issue insulin delivery commands.

Other names: Tandem t:slim X2 with Control-IQ Technology, Tandem t:slim X2 with Basal-IQ Technology

Primary outcomes

  1. CGM Measured Time <70 mg/dL

    Time frame: weeks 5-12 of 12 weeks for each intervention of the crossover

    Primary Outcome: Percentage of sensor glucose values <70 mg/dL. The first 4 weeks of CGM data in each period were excluded to reduce the chance of a carryover effect. A minimum of 168 hours of data was required to calculate CGM metrics. Since the hypoglycemia endpoints had skewed distributions, values were winsorized at the 10th and 90th percentiles.

Secondary outcomes

  1. CGM Measured Time <54 mg/dL

    Time frame: weeks 5-12 of 12 weeks for each intervention of the crossover

    Percentage of sensor glucose values <54 mg/dL. The first 4 weeks of CGM data in each period were excluded to reduce the chance of a carryover effect. A minimum of 168 hours of data was required to calculate CGM metrics. Since the hypoglycemia endpoints had skewed distributions, values were winsorized at the 10th and 90th percentiles.

  2. Hypoglycemia

    Time frame: weeks 5-12 of 12 weeks for each arm of the crossover

    Rate of CGM-measured hypoglycemic events per week. A hypoglycemic event is defined as 15 consecutive minutes with a sensor glucose value <54 mg/dl. At least 2 sensor values <54 mg/dl that are 15 or more minutes apart plus no intervening values >54 mg/dl are required to define an event. The end of the hypoglycemic event is defined as a minimum of 15 consecutive minutes with a sensor glucose concentration >70 mg/dl. At least 2 sensor values >70 mg/dl that are 15 or more minutes apart with no intervening values <70 mg/dl, are required to define the end of an event. When a hypoglycemic event ends, the study participant becomes eligible for a new event.

  3. Glucose Control

    Time frame: weeks 5-12 of 12 weeks for each arm of the crossover

    Mean glucose (mg/dL)

  4. % Time 70-180 mg/dL

    Time frame: weeks 5-12 of 12 weeks for each intervention of the crossover

    Percentage of sensor glucose values 70 to 180 mg/dL. The first 4 weeks of CGM data in each period were excluded to reduce the chance of a carryover effect. A minimum of 168 hours of data was required to calculate CGM metrics.

  5. Glucose Control - Coefficient of Variation

    Time frame: weeks 5-12 of 12 weeks for each arm of the crossover

    Coefficient of variation (%)

  6. % Time > 180 mg/dL

    Time frame: weeks 5-12 of 12 weeks for each intervention of the crossover

    Percentage of values >180 mg/dL. The first 4 weeks of CGM data in each period were excluded to reduce the chance of a carryover effect. A minimum of 168 hours of data was required to calculate CGM metrics.

  7. % Time > 250 mg/dL

    Time frame: weeks 5-12 of 12 weeks for each intervention of the crossover

    Percentage of values >250 mg/dL. The first 4 weeks of CGM data in each period were excluded to reduce the chance of a carryover effect. A minimum of 168 hours of data was required to calculate CGM metrics.

  8. HbA1c

    Time frame: at 12 week visit for each arm of the crossover

    HbA1c %

  9. Hypoglycemia Unawareness - Gold Survey

    Time frame: at 12 week visit for each arm of the crossover

    The Gold score asks subjects to indicate their awareness of hypoglycemia with '1' being always aware and '7' being never aware.

    Score scale 1-7; A higher score indicates more unawareness.

Other outcomes

  1. Patient Reported Questionnaires - Hypoglycemia Fear Survey

    Time frame: at 12 week visit for each arm of the crossover

    The Hypoglycemia Fear Survey measures several dimensions of fear of hypoglycemia among adults with type 1 diabetes. It consists of a 15-item Behavior subscale that measures behaviors involved in avoidance and over-treatment of hypoglycemia and a 18-item Worry subscale that measures anxiety and fear surrounding hypoglycemia. Scores will be calculated overall and for the worry subscale.

    Score scale 0-4; A higher score indicates more fear.

  2. Patient Reported Questionnaires - Hypoglycemia Confidence

    Time frame: at 12 week visit for each arm of the crossover

    The HCS is a 9-item scale that examines the degree to which people with diabetes feel able, secure, and comfortable regarding their ability to stay safe from hypoglycemic-related problems.

    Score scale 1-4.; A higher score indicates more confidence.

  3. Patient Reported Questionnaires - Diabetes Distress Scale

    Time frame: at 12 week visit for each arm of the crossover

    28-item questionnaire used to measure diabetes-related concerns about powerlessness, management, hypoglycemia, social perceptions, eating, physician, and friends/family.

    Score scale 1-6; A higher score indicates more distress.

  4. Patient Reported Questionnaires - AIDE Technology Acceptance

    Time frame: at 12 week visit for each arm of the crossover

    This diabetes technology specific questionnaire based on the Technology Acceptance Model, assesses perceived system usefulness, ease of use and trust in the system.

    Score scale 1-5; A higher score indicates a more positive appraisal of the system.

  5. Patient Reported Questionnaires - System Usability

    Time frame: at 12 week visit for each arm of the crossover

    A 10-item questionnaire that measures overall perceived usability of a system and is technology-agnostic.

    Score scale 0-100; Higher score indicates better usability

Sponsors and collaborators

Lead sponsor

Jaeb Center for Health Research

Other

Collaborators

  • AdventHealth Diabetes Institute
  • DexCom, Inc.
  • Mayo Clinic
  • National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
  • Tandem Diabetes Care, Inc.
  • University of Minnesota - Advanced Research and Diagnostic Laboratory
  • University of Pennsylvania
  • Washington State University

Registry information

Official study title

A Randomized Cross-over Trial Evaluating Automated Insulin Delivery Technologies on Hypoglycemia and Quality of Life in Elderly Adults With Type 1 Diabetes

Acronym: AIDE T1D

Important dates

Study start
2020
Primary completion
2023
Study completion
2024
First posted
Jul 11, 2019
Registry last updated
Jan 15, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.