Universitair Ziekenhuis Brussel
Jette, 1090, Belgium
NCT Number: NCT06571539
The goal of this clinical trial is to learn if high-accuracy augmented reality (AR) guidance for external ventricular drain (EVD) placement using a standalone head-worn navigation system can improve current shortcomings of freehand and image-guidance techniques. It will assess safety, feasibility and clinical performance. The main questions it aims to answer are:
* Is the implementation of a standalone head-worn AR navigation system for EVD placement in critical care settings feasible and safe? * How does it compare to the conventional freehand technique in terms of EVD placement quality, complication rate and revision rate?
Researchers will assess placement quality using the modified Kakarla scale, grading placement quality based on the position of the EVD tip on postoperative CT imaging. The amount of attempts, complications and revisions will be documented. The results of the AR-guided placements will be compared to a matched, non-concurrent freehand control group.
Participants will undergo AR-guided EVD placement in a critical care setting (i.e. the emergency room or intensive care unit).
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Jette, 1090, Belgium
External ventricular drain (EVD) placement is often performed using the freehand technique. In comparison to image-guided methods, this technique was identified as the primary risk factor of improper outcome, yielding optimal placement in only 70%. While conventional image guidance technologies introduce a distinct improvement in accuracy, these systems tend to be prohibitively large and lack mobility, restricting their use to the operating room. As such, their practical implementation in critical care settings is not always feasible due to time, availability, and cost constraints.
This study aims to address shortcomings in both conventional EVD placement and current image guidance technologies. To achieve this, first an AR headset-based navigation system was developed, providing high-accuracy inside-out infrared tracking and software features specifically focusing on EVD placement. Phantom studies were conducted, which proved successful, with a positive outcome of AR-guided EVD placement on phantom heads over the freehand technique. Given these results, the researchers aim to test the system in a clinical trial setting.
Given the additional layer of information on top of knowledge and experience regarding the freehand technique, it is hypothesized that AR guidance will result in an improved outcome, as was the case for conventional neuronavigation.
This study is a prospective clinical pilot study, with the goal to assess feasibility, safety and clinical performance of high-accuracy AR-guided EVD placement using a standalone head-worn navigation system in critical care settings at the Universitair Ziekenhuis Brussel over the course of one year. The outcome will be quantified using the modified Kakarla scale to assess EVD placement quality on postoperative CT imaging, as well as the amount of attempts, complications and revisions. The results of the AR-guided placements will be compared to a non-concurrent control group of matched (for quantity, intervention, performing surgeons and timeframe) freehand EVD placement cases that will be collected retrospectively.
The study protocol was approved by the Ethics Committee of the Universitair Ziekenhuis Brussel (ref. 2018/447) and validated by the Belgian Federal Agency of Medicines and Health Products (FAGG/AFMPS ref. 80M0764).
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Cfr. arm description
External ventricular drain (EVD) placement using the conventional freehand technique. This intervention covers the matched, non-concurrent control group, retrospectively obtained without active enrollment to receive study treatment.
Time frame: Within 24 hours after surgery
External ventricular drain (EVD) placement quality assessment using the modified Kakarla scale (mKS; with grades I (a and b), II and III), grading placement quality based on the EVD tip position (identified on the postoperative CT imaging) from optimal placement (mKS grade Ia) to poor or failed placement (mKS grade III).
Time frame: During surgery
The number of attempts required for successful ventricular puncture
Time frame: Within 7 days after surgery
The amount and type of complications related to the EVD placement procedure (e.g. hemorrhage, infection)
Time frame: Within 24 hours after surgery
The amount of revisions required in case of non-functional EVD placement
Time frame: Within 7 days after inclusion of the last patient
All participating surgeons will be asked to complete a questionnaire gauging their subjective experience regarding the use of the system (likelihood of technology-acceptance cfr. UTAUT model, subjective ease-of-use, any discomforts)
Universitair Ziekenhuis Brussel
Other
High-accuracy Augmented Reality Guidance for Intracranial Drain Placement Using a Standalone Head-worn Navigation System
Acronym: ARANED
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05593380
Brain Diseases, Brain Edema
Changde, Hunan, China
View Trial DetailsNCT06939114
Brain Diseases, Cardiovascular Diseases
Zurich, Canton of Zurich, Switzerland
View Trial DetailsNCT06367868
Brain Diseases, Central Nervous System Diseases
Istanbul, Fatıh, Turkey (Türkiye)
View Trial DetailsNCT06039098
Brain Diseases, Brain Injuries
London, United Kingdom
View Trial Details