Skip to main content
OpenTrials
Completed

NCT Number: NCT05872516

Atrial Fibrillation Detecting Software Gung Atrial Fibrillation Detecting Software

Chang Gung Atrial Fibrillation Detection Software is an artificial intelligence electrocardiogram signal analysis software that detects whether a patient has atrial fibrillation by static 12-lead ECG signals. This study is a non-inferiority test based on the control group. The main purpose is to verify whether Chang Gung atrial fibrillation detection software can correctly identify atrial fibrillation in patients with atrial fibrillation, and can be used to provide a reference for doctors to detect atrial fibrillation.

Completed

Looking for future studies?

Notify Me

Key information

Age range

20 year–100 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Chang Gung memorial hospital

Taoyuan City, 333, Taiwan

About this study

This study is a retrospective study, and the data is from the six hospitals of Chang Gung Medical Research Database (CGRD). We collected de-identified static 12-lead electrocardiogram (ECG) data from the database during the period of January 1, 2006, to December 31, 2019.

We created a training set and a testing set of ECG data from the CGRD. Then, we stratified and sampled ECG signals from the testing set according to the actual proportion to obtain the experimental sample.

The computer first preliminarily screened and selected ECG data that met the inclusion and exclusion criteria, and then numbered them sequentially. A cardiologist confirmed that the sampled ECG data did not include exclusion criteria.

The ECG data were converted into images and interpreted for the presence or absence of atrial fibrillation by three cardiologists. Their results were used as the gold standard (reference) for this study.

After determining the experimental standards, the ECG signals were inputted into the Chang Gung Atrial Fibrillation Detection software for analysis and interpretation of each ECG data.

After the software interpretation was completed, the results were compared with the interpretations of the physicians, and the primary and secondary evaluation indicators were analyzed accordingly.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Equal or greater than twenty years old
  • Static 12-lead electrocardiogram of General Electric MUSE XML format file.
  • The data comes from the static 12-lead electrocardiogram device of General Electric (model MAC5500).
  • The electrocardiogram signal is 500 Hz.
  • The Alternating current (AC) filter of the electrocardiogram signal is 60 Hz.

Exclusion criteria

  • Cases used in the model development process.
  • Lacks any electrode.
  • Contain any electrode lacks a segment.
  • Misplaced leads

Treatment and study plan

Chang Gung Atrial Fibrillation Detecting Software

Device

This software is expected to be used in clinical testing to interpret the static 12-lead ECG of adults who are over 20 years old and suspected of having atrial fibrillation, detect whether there is a signal of atrial fibrillation, and output the results for clinicians Near-instant auxiliary diagnostic use.

Primary outcomes

  1. Sensitivity

    Time frame: baseline

    The rate of test results that correctly indicate the presence.

Secondary outcomes

  1. Specificity

    Time frame: baseline

    The rate of test results that correctly indicate the absence.

  2. Accuracy

    Time frame: baseline

    The rate of all test results that correctly indicate.

  3. Area Under the receiver operating characteristic Curve

    Time frame: baseline

    A graphical plot that illustrates the diagnostic ability of a binary classifier system as its discrimination threshold is varied.

  4. Positive predictive value

    Time frame: baseline

    The proportions of positive results in statistics and diagnostic tests that are true positive results

  5. Negative predictive value

    Time frame: baseline

    The proportions of negative results in statistics and diagnostic tests that are true negative results

  6. False positive rate

    Time frame: baseline

    The rate of test result which wrongly indicates that a particular condition or attribute is present

  7. False negative rate

    Time frame: baseline

    The rate of test result which wrongly indicates that a particular condition or attribute is absent

Sponsors and collaborators

Lead sponsor

Chang Gung Memorial Hospital

Other

Registry information

Official study title

A Study to Evaluate Accuracy and Validity of the Chang Gung Atrial Fibrillation Detecting Software

Important dates

Study start
2022
Primary completion
2023
Study completion
2023
First posted
May 24, 2023
Registry last updated
May 24, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.