Skip to main content
OpenTrials
Active, Not Recruiting

NCT Number: NCT05748379

Atraumatic Zirconia Abutment Versus Customized Composite Healing Abutment in Maxilla or Mandible.

40 patients are included in the study, 20 patients in group 1 (=closure with composite material shaper; test group) and 20 patients in group 2 (=closure with custom-made zirconia oxide abutment; control group).

Randomisation envelopes will be used for randomisation. Device under study: Straumann BLX, Roxolid® , SLActive® dental implants with a diameter of 3.5, 3.75, 4, 4.5 mm are used.

Allogenic bone botiss maxgraft® cortical granules are used as graft material.

Inclusion criteria:

1. Males and females at least 18 years of age or older. 2. One implant per patient. 3. Prior to any study-related activity, the subject must voluntarily sign informed consent, be willing and able to attend scheduled follow-up visits, and agree to the collection and analysis of pseudonymised data. 4. Lateral individual teeth (premolars and molars). 5. Class I extraction socket (intact buccal wall) or class II (1/3 of buccal wall). 6. The gingival contour of the tooth to be extracted - without recession. 7. Adjacent anterior teeth have no periodontal loss. 8. There are no implants in the adjacent teeth. 9. Non-traumatic tooth extraction, which results in intact walls of the socket.

Exclusion criteria:

1. Deep occlusion (severe, class II). 2. The patient smokes a lot (more than 10 cigarettes per day). 3. Systemic disease (osteoporosis). 4. No initial stability has been achieved after the implant insertion procedure.

Active, Not Recruiting

This study is active but is not currently recruiting participants.

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Adenta

Riga, Latvija, LV-1045, Latvia

About this study

General Notes

40 patients are included in the study, 20 patients in group 1 (=closure with composite material shaper; test group) and 20 patients in group 2 (=closure with custom-made zirconia oxide abutment; control group).

Randomisation envelopes will be used for randomisation. Device under study: Straumann BLX, Roxolid® , SLActive® dental implants with a diameter of 3.5, 3.75, 4, 4.5 mm are used.

Allogenic bone botiss maxgraft® cortical granules are used as graft material.

Inclusion criteria

  • Males and females at least 18 years of age or older.
  • One implant per patient.
  • Prior to any study-related activity, the subject must voluntarily sign informed consent, be willing and able to attend scheduled follow-up visits, and agree to the collection and analysis of pseudonymised data.
  • Lateral individual teeth (premolars and molars).
  • Class I extraction socket (intact buccal wall) or class II (1/3 of buccal wall).
  • The gingival contour of the tooth to be extracted - without recession.
  • Adjacent anterior teeth have no periodontal loss.
  • There are no implants in the adjacent teeth.
  • Non-traumatic tooth extraction, which results in intact walls of the socket.

Exclusion criteria

  • Deep occlusion (severe, class II).
  • The patient smokes a lot (more than 10 cigarettes per day).
  • Systemic disease (osteoporosis).
  • No initial stability has been achieved after the implant insertion procedure. 4.2. Surgical Procedures and Recovery Phase (see Annexes No. 1 and 2)

Group 1. Immediate implant placement and temporary closure of tapered implants with a custom-made composite shaper after tooth extraction with bone augmentation by using allogeneic bone.

  • Non-traumatic extraction.
  • Palatal position of tapered implant for premolars and centred position for molars (more commonly - in the septum) 3-4 mm below the buccal gum line or 1-2 mm below the bony protuberance.
  • For premolars, the implant is placed palatally 2-3 mm to the buccal bone wall, for molars 2-3 mm to the buccal and lingual wall.
  • Implant insertion.
  • "Jump distance" sealing with allogeneic bone.
  • Temporary closure with a composite shaper.
  • Cone beam computed tomography with Carestream machine.
  • Taking a photo.
  • Scan with 3Shape TRIOS4 scanner.

After 3 months, a cone beam computed tomography is performed to evaluate changes in the crestal bone, the temporary restoration is screwed off and the presence/absence of bleeding is recorded. A digital impression is taken for a zirconium oxide crown made on Ti base and to assess soft tissue changes.

The change in the buccal vertical bone level will be measured as the difference between the former and the new vertical distance from implant platform to the buccal alveolar crest.

While the change in the buccal horizontal bone dimension will be measured as the difference between the former and the new horizontal distance between the implant and the outer surface of the buccal plate. Both measurements will be taken using CBCT, one immediately after the surgery and the other one 3 month later.

Intraoral scans with 3Shape Trios4 dental scanner will be taken to compare soft tissue stability. Measurements will be taken before, immediately after the surgery and 3 month later. By using STL files it will be possible to compare soft tissue stability.

Group 2. Immediate implant placement and temporary closure of tapered implant with a custom-made zirconium oxide abutment after tooth extraction with bone augmentation by using allogeneic bone.

  • Non-traumatic extraction.
  • Palatal position of tapered implant for premolars and centred position for molars (more commonly - in the septum) 3-4 mm below the buccal gum line or 1-2 mm below the bony protuberance.
  • For premolars, the implant is placed palatally 2-3 mm to the buccal bone wall, for molars 2-3 mm to the buccal and lingual wall.
  • Implant insertion.
  • "Jump distance" sealing with allogeneic bone.
  • Closure with a zirconium oxide abutment.
  • Cone beam computed tomography with Carestream machine.
  • Taking a photo.
  • Scan with 3Shape TRIOS4 scanner.

After 3 months, a cone beam computed tomography is performed to evaluate changes in the crestal bone, the custom-made abutment is screwed off and the presence/absence of bleeding is recorded. A digital impression is taken for a zirconium oxide crown and to assess soft tissue changes.

The change in the buccal vertical bone level will be measured as the difference between the former and the new vertical distance from implant platform to the buccal alveolar crest.

While the change in the buccal horizontal bone dimension will be measured as the difference between the former and the new horizontal distance between the implant and the outer surface of the buccal plate. Both measurements will be taken using CBCT, one immediately after the surgery and the other one 3 month later.

Intraoral scans with 3Shape Trios4 dental scanner will be taken to compare soft tissue stability. Measurements will be taken before, immediately after the surgery and 3 month later. By using STL files it will be possible to compare soft tissue stability.

Evaluation Phase

T1 (Basic): After the performance of final restoration: X-ray, photograph, scan, PD, BOP, RI.

T2: Follow-up after 3 months: X-ray, photograph, scan, PD, BOP, RI. T3: Follow-up after a year: X-ray, photograph, scan, PD, BOP, RI.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Males and females at least 18 years of age or older.
  • One implant per patient.
  • Prior to any study-related activity, the subject must voluntarily sign informed consent, be willing and able to attend scheduled follow-up visits, and agree to the collection and analysis of pseudonymised data.
  • Lateral individual teeth (premolars and molars).
  • Class I extraction socket (intact buccal wall) or class II (1/3 of buccal wall).
  • The gingival contour of the tooth to be extracted - without recession.
  • Adjacent anterior teeth have no periodontal loss.
  • There are no implants in the adjacent teeth.
  • Non-traumatic tooth extraction, which results in intact walls of the socket.

Exclusion criteria

  • Deep occlusion (severe, class II).
  • The patient smokes a lot (more than 10 cigarettes per day).
  • Systemic disease (osteoporosis).
  • No initial stability has been achieved after the implant insertion procedure

Treatment and study plan

Kompozite closure

Procedure

Immediate implant placement and temporary closure of tapered implants with a custom-made composite shaper.

Individual abutment

Procedure

Immediate implant placement and temporary closure of tapered implant with a custom-made zirconium oxide abutment.

Primary outcomes

  1. Stability of crestal bone

    Time frame: Before surgery, immediately after surgery, 3 moth, 1 year follow up

    To compare crystal bone stability CBCT will be taken before surgery. , immediately after surgery, after 3 month and a follow up after 1 year.

    The change in the buccal vertical bone level will be measured as the difference between the former and the new vertical distance from implant platform to the buccal alveolar crest.

    While the change in the buccal horizontal bone dimension will be measured as the difference between the former and the new horizontal distance between the implant and the outer surface of the buccal plate. Both measurements will be taken using CBCT, one immediately after the surgery and the other one 3 month later

  2. The changes of stability of soft tissue

    Time frame: Before surgery, immediately after surgery, 3 month, 1 year follow up

    Recession (REC) state of the gingival/mucosa border - registered by means of a periodontal probe from the incisal edge to the border of the medial, zenith and distal zones.

    There are taken scans with 3Shape Trios4 before surgery, immediately after, then 3 month and 1 year follow up to compare soft tissue stability

  3. The change of position of implant using surgical guide

    Time frame: Before surgery and immediately after surgery

    To compare implant position accuracy using surgical guide, the following two things will be compared: DICOM after the surgery witch contains information on the implant position in the bone and the STL file witch contains information on implant position before the surgery.

    There are taken cone beam computer tomography before and immediately after surgery, then 3 month and 1 year follow up.

Sponsors and collaborators

Lead sponsor

SIA Adenta

Other

Registry information

Official study title

Closure of a Guided Immediate Implant Placed in the Extraction Socket With Bone Augmentation in the Lateral Area of the Maxilla or Mandible, With a Temporary Composite Abutment vs With a Custom-made Zirconium Oxide Abutment.

Important dates

Study start
2023
Primary completion
2024
Study completion
2025
First posted
Feb 28, 2023
Registry last updated
May 14, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.