NIV can be combined with other treatments that require to introduce gas into the circuit during the treatment. This external gas produces trigger asynchronies that worse depending on the model ventilator, trigger design and gas source. It is advisable to monitor NIV when these treatments are requiring in chronic NIV.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Observational
Sabadell, Barcelona, 08208, Spain
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The procedure was performed in the patient's room during his or her hospital stay to avoid additional visits for study participation. The patient was placed in the supine position, and the usual ventilator interface was placed in a single-limb system, along with the commercial ventilator to be studied. The ventilator model were evaluated at bedside in random order. The parameters of the ventilator were the same as those that the patients used at home (that is, unlike the bench study, the sensitivity of the trigger was not modified). A external polygraph was used to moritor the study, with the incorporation of thoracic and abdominal bands and parasternal electromyography, to better evaluate asynchronies, in addition to pulse oximetry control. The ventilation periods were 1 minute (without gas, gas, without gas). This sequence was performed twice in each group of established conditions.
Time frame: 1 day
Presence of asynchronies identify by SOMNONIV´s algorithm during the gas treatment with NIV
Time frame: 1 day
autotrigger or innefective effort identify by SOMNONIV´s group algorithm, during the gas treatment with NIV
Time frame: 1 day
autotrigger or innefectuve effort identify by SOMNONIV´s group pre gas during NIV treatment
Time frame: 1 day
autotrigger or innefective effort identify by SOMNONIV´s group algorithm, , post gas during NIV
Time frame: 1 day
Presence of asynchronies identify by SOMNONIV´s algorithm during pre-gas treatment with NIV
Time frame: 1 day
Presence of asynchronies identify by SOMNONIV´s algorithm during the post gas treatment with NIV
Corporacion Parc Tauli
Other
Trigger Asynchronies Induced by the Introduction of External Gas Into the Non-invasive Mechanical Ventilation Circuit: a Bench-to-bedside Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05796297
Asynchrony Between Patient and Ventilator, Chronic Respiratory Failure
Nantes, Loire-Atlantique, France
View Trial DetailsNCT04178694
Energy Expenditure, Metabolism
Jette, Brussels Capital, Belgium
View Trial DetailsNCT02973373
Apnea, Healthy Volunteer
Lausanne, Switzerland
View Trial DetailsNCT03859947
Bronchial Diseases, Bronchiolitis
Izmir, Turkey (Türkiye)
View Trial Details