This study aims to investigate in healthy adults 18-65 years of age the association of electronic device blue light exposure and macular pigment optical density (MPOD) considering usual dietary intake of lutein and zeaxanthin (L/Z) as confirmed by serum lutein and zeaxanthin concentrations.

It is hypothesised in healthy adults 18-65 years of age:

1. Higher usual daily electronic device blue light exposure will be negatively correlated with MPOD value. 2. Usual dietary intake of L/Z will be positively correlated with MPOD value. 3. L/Z concentration will be positively correlated with MPOD value. 4. Usual dietary intake of L/Z will be positively correlated with plasma L/Z concentrations. 5. Higher usual intake of L/Z will mitigate the effect of higher electronic device exposure on MPOD value.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–65 year

Sex eligibility

All sexes

Study type

Observational

Primary location

School of Human Movement and Nutrition Sciences, The University of Queensland

Saint Lucia, Queensland, 4067, Australia

About this study

Exponential uptake of modern technology over the last 30 years (computers) and 10 years (smartphones) has resulted in remarkable increase in artificial blue light exposure amongst all age groups. This suggests the incidence of age-related macular degeneration (AMD) could be increasing significantly in the population in the years to come. It is unknown whether the extent of daily blue light exposure influences macular pigment optical density (MPOD) in young to middle age adults. Stringham et al. (2017) showed that, in 18-25 year old healthy adults, exposed to electronic devices over 6 hours daily, MPOD value and visual performance significantly improved after 6 months of lutein/zeaxanthin/meso-zeaxanthin supplementation. The findings of this project may inform on the risks of high exposure to electronic screens and the need to address with preventive measures the potential decline in MPOD and increased risk of AMD. The impact of usual dietary intake of macular xanthophylls on circulating concentrations and MPOD will be investigated. Findings may inform guidelines on recommended daily intake of these food constituents either through diet or supplementation.

Data Management and Confidentiality of Data Collected:

Consent is sought for extended use of the collected data which means it may be used in future research. For example, in the future if more sensitive methods for detecting L/Z, or other macular pigments become available, stored blood samples may be re-analysed. Furthermore, data may be used for subsequent statistical analysis and statistical analysis may be published in peer-reviewed journals, however no identifiable personal details will be published or used. Any personal information, such as full name and date of birth will remain confidential to only the study investigators at all times.

All hard copy personal information and measures taken as part of the study protocol will be stored in locked filing cabinets when not in use, and will only be accessible to approved study investigators. Any electronic data collected for the study will be stored using the UQ Research Data Management system. Data will be de-identified through the use of participant ID numbers allocated at enrolment. Re-identification of participant information will only be accessible by study investigators. At the conclusion of the study, participant hard copy files and trial documents are kept in locked filing cabinets for a period of 15 years. After this time, records will be disposed of by a certified record destruction, such as shredding.

Blood samples will be collected for research purposes, specifically for the measurement of plasma lutein and zeaxanthin concentrations. Collected samples will be stored as per the extended consent sought, held for up to 15 years. After this time, they will be destroyed via incineration. Collected plasma samples will only be identifiable via the participant study number allocated at enrolment. All publicly shared data or data used in publications will be in a non-identifiable form.

Data recorded and maintained for this trial will be controlled in accordance with the national Privacy Principles and Privacy Act 1988.

Sample Size:

Sample size calculation was performed on the basis of a MPOD coefficient of variation of 0.187 optical density units (ODU) measured in a sample of 5581 adults using the Macular Pigment Screener II (18). A minimum of 105 participants was calculated using a two tailed, random model, linear multiple regression with an alpha error probability: 0.05, power: 0.90, number of predictors: 4. This also allows for a 20% drop out rate.

Statistical Tests:

Analysis will be conducted using GraphPad Prism 8. Participants will be stratified by MPOD.

  • Descriptive statistics will be performed.
  • All data will be tested for normality of distribution using the D'Agostino-Pearson normality test.
  • Based on the outcome of testing for normality of distribution, Spearman or Pearson's correlations will be used to test for correlation between the following variables.
  • MPOD and daily hours of electronic device use.
  • MPOD and usual dietary intake of lutein and zeaxanthin (L/Z).
  • MPOD and serum L/Z concentration.
  • Serum L/Z concentration and usual dietary intake of L/Z.
  • Multiple linear regression will be used to test for correlation to MPOD with the following variables:
  • Daily hours of electronic device use.
  • Usual dietary intake of L/Z.
  • Age
  • Gender

Results will be considered statistically significant if p<0.05.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Male and females 18 to 65 years.
  • Generally healthy.
  • No participant reported history of clinically significant medical conditions including, but not limited to, cardiovascular, neurological, psychiatric, renal, immunological, endocrine (including uncontrolled diabetes or thyroid disease) or haematological abnormalities that are uncontrolled.
  • Non-smoker

Exclusion criteria

  • Participant reported diagnosis of serious ocular conditions (e.g. cataracts, glaucoma, diabetic retinopathy, retinitis pigmentosa, Stagardt's disease)
  • Participant reported diagnosis, or current treatment of age-related macular degeneration.
  • Participant reported diagnosis of epilepsy.
  • Current or past smoker (within last 12 months).
  • Under 18 or over 65 years of age.

Treatment and study plan

Primary outcomes

  1. Macular Pigment Optical Density

    Time frame: Triplicate measurement day 1

    Machine: Macular Pigment Screener II (Elektron Eye Technology). The non-invasive test uses heterochromatic flicker photometry.

Secondary outcomes

  1. Dietary intake of lutein and zeaxanthin

    Time frame: Retrospective intake prior one month

    Daily intake of lutein and zeaxanthin (mg/day) measured by food frequency questionnaire.

  2. Usual use of electronic devices.

    Time frame: Retrospective use of devices prior 3 months.

    Capturing exposure to blue light from electronic devices through questionnaire that asks participants to record usual hours of device use each day over last 3 months.

  3. Blood lutein and zeaxanthin concentration

    Time frame: Single sample drawn on day of study visit (Day 1).

    Single sample of plasma to measure concentration of lutein and zeaxanthin by high performance liquid chromatography and photodiode array detection.

Other outcomes

  1. Dietary intake of lutein and zeaxanthin on day prior to study visit.

    Time frame: Intake over single day prior to study visit (Day 1).

    24-hour diet recall to calculate dietary intake (mg/day) of lutein and zeaxanthin.

Sponsors and collaborators

Lead sponsor

The University of Queensland

Other

Registry information

Official study title

Investigating Associations Between Chronic Electronic Device Blue Light Exposure, Dietary Xanthophyll Intake and Macular Pigment Density in Humans.

Acronym: AMPBL19

Important dates

Study start
2020
Primary completion
2022
Study completion
2022
First posted
Mar 3, 2021
Registry last updated
May 19, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.