Skip to main content
OpenTrials
Completed

NCT Number: NCT05286073

Assessment of Vertical Root Fracture Resistance of Endodontically Treated Teeth Instrumented by Single Endodontic Files

The purpose of this study is the assessment of vertical root fracture resistance of roots prepared with three different single endodontic rotary files in extracted human mandibular premolar roots.

Completed

Looking for future studies?

Notify Me

Key information

Age range

25 year–40 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Dow University of Health Sciences

Karachi, Sindh, 75300, Pakistan

About this study

88 human extracted mandibular premolars will be selected. Teeth will be sectioned below cementoenamel junction to get 13mm from the apex of root. Roots will then be standardized according to buccolingual and mesiodistal widths and will be examined for fracture and craze lines. The roots will then be randomly divided into 3 experimental groups and 1 control group (n=22). Group 1 will be instrumented with Hyflex EDM. Group 2 will be instrumented with F6 Sky Taper. Group 3 will be instrumented with One Shape and Group 4 will be negative control group in which no instrumentation will be done. After performing rotary instrumentation, roots will then be obturated with respective GP and sealer. Samples will then be exposed to vertical load utilizing Universal Testing Machine till fracture occur which will be recorded in Newton(N).

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Extracted Human mandibular premolar canals that fulfill the following criteria were used.
  • permanent teeth
  • intact and fully formed apices
  • straight and single rooted canal
  • roots having similar diameter mesiodistally(2-4mm) and buccolingually(4-6mm)

Exclusion criteria

  • Roots having following features were excluded;
  • root caries
  • roots with multiple canals
  • previous root canal treatment done
  • signs of calcification, internal and external root resorption
  • cracks
  • fracture lines
  • C-shaped canals
  • Vertical Root Fracture

Treatment and study plan

Endodontic Root Canal Treatment

Procedure

Root canal shaping procedures were performed. Irrigation was done after each three pecks of endodontic file. After instrumentation (Groups 1-3), the canals were dried with sterile paper points. The dentinal walls were then coated with Sealapex. For vertical root fracture resistance testing, sample preparation was done in acrylic blocks. Then roots were coated with polyvinylsiloxane impression material. After that roots were inserted again into acrylic resin blocks. The acrylic blocks with the vertically aligned roots were mounted in the Instron testing machine. 0.5 mm diameter round tip stainless-steel rod was fixed to the universal testing machine. The universal testing machine was adjusted and vertical compressive force was applied at a crosshead speed of 1mm/min. The Instron tester applied a slowly increasing force, until the root fractured. The maximum amount of force necessary to fracture every sample was recorded in Newton (N).

Primary outcomes

  1. Vertical Root Fracture Resistance

    Time frame: 5 minutes

    The acrylic blocks with the vertically aligned roots were mounted in the Instron testing machine one at a time. 0.5 mm diameter round tip stainless-steel rod was fixed to the upper stage of the universal testing machine (Instron, Canton, MA, USA). The rod was centered over the canal orifice of each root. The universal testing machine (Instron) was adjusted and vertical compressive force was applied at a crosshead speed of 1mm/min. The Instron tester applied a slowly increasing force, at a rate of 1.0 mm per min, until the root fractured. This point was verified by the computer monitoring the Instron testing machine; at the same time the crack was heard, the monitor showed a sharp drop in force. The test was terminated at this point and the force applied was recorded. The maximum amount of force necessary to fracture every sample was recorded in Newton (N).

Secondary outcomes

  1. Crack pattern

    Time frame: 2 minutes

    crack pattern is complete/incomplete

Sponsors and collaborators

Lead sponsor

Dow University of Health Sciences

Other

Registry information

Important dates

Study start
2019
Primary completion
2022
Study completion
2022
First posted
Mar 18, 2022
Registry last updated
Mar 18, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.