Pulse Field Ablation
DevicePFA ablation using a circular multi-electrode pulsed electrical field catheter and multichannel generator
NCT Number: NCT05293639
To demonstrate the safety and 12-month effectiveness of the VARIPULSE™ Catheter when used in conjunction with the TRUPULSE™ Generator for pulmonary vein isolation (PVI) in the treatment of subjects with symptomatic paroxysmal atrial fibrillation.
Looking for future studies?
Notify Me18 year–75 year
All sexes
Interventional
Not applicable
Grandview Medical Center, Birmingham, Alabama, United States
This is a prospective, non-randomized, multi-center, clinical evaluation of the Biosense Webster IRE Ablation system to demonstrate safety and long-term effectiveness for the treatment of drug refractory symptomatic PAF. The BWI IRE Ablation System consists of the VARIPULSE™ Catheter and TRUPULSE™ Generator. In conjunction with CARTO™ 3 system, it is indicated for PVI of patients with drug refractory paroxysmal atrial fibrillation.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Key Inclusion Criteria:
Exclusion criteria
PFA ablation using a circular multi-electrode pulsed electrical field catheter and multichannel generator
Time frame: From Day 0 to Day 7 post catheter insertion on Day 0
An adverse event (AE) was any untoward medical occurrence in a participant participating in a clinical study that does not necessarily have a causal relationship with the pharmaceutical/biological agent under study. PAEs included the following AEs: Phrenic Nerve Paralysis (permanent), Stroke/Cerebrovascular accident (CVA), Major Vascular Access Complication/Bleeding, Thromboembolism, Myocardial Infarction, Transient Ischemic Attack (TIA), Pericarditis, Pulmonary Edema (Respiratory Insufficiency), Heart Block, and Vagal Nerve Injury/ Gastroparesis.
Time frame: From Day 0 to Day 7 post catheter insertion on Day 0
An adverse event (AE) is any untoward medical occurrence in a participant participating in a clinical study that does not necessarily have a causal relationship with the pharmaceutical/biological agent under study. PAEs included the following AEs: Phrenic Nerve Paralysis (permanent), Stroke/CVA, Major Vascular Access Complication/Bleeding, Thromboembolism, Myocardial Infarction, Transient Ischemic Attack (TIA), Pericarditis, Pulmonary Edema (Respiratory Insufficiency), Heart Block, and Vagal Nerve Injury/ Gastroparesis.
Time frame: Day 91 to Day 365 post catheter insertion on Day 0
Number of Participants With freedom from documented (symptomatic and asymptomatic) atrial tachyarrhythmia (atrial fibrillation [AF], atrial tachycardia [AT], or atrial flutter [AFL] of unknown origin positive) episodes based on electrocardiographic data (greater than or equal to [>=] 30 seconds on an electrocardiogram [ECG], sponsor-provided cardiac event monitor [CEM], or Holter device) during the effectiveness evaluation period (Day 91-365 post catheter insertion procedure) and freedom from the following failure modes: acute procedural failure, repeat ablation failure, non-study catheter failure, AAD failure, continuous AF/AT/AFL of unknown origin on ECG, any Direct Current Cardioversion (DCCV) procedure were reported.
Time frame: Day 91 to Day 365 post catheter insertion on Day 0
Number of Participants With freedom from documented (symptomatic and asymptomatic) atrial tachyarrhythmia (AF, AT, or AFL of unknown origin positive) episodes based on electrocardiographic data (>=30 seconds on an ECG, CEM, or Holter device) during the effectiveness evaluation period (Day 91-365 post catheter insertion) and freedom from the following failure modes: acute procedural failure, repeat ablation failure, non-study catheter failure, AAD failure, continuous AF/AT/AFL of unknown origin on ECG, any DCCV procedure were reported.
Time frame: Baseline, and 12 months post catheter insertion on Day 0
Change from baseline in overall AFEQT total score were reported. Change in the AFEQT score included 20 questions on a 7-point Likert scale. Questions 1-18 evaluated Health Related Quality of Life (HRQoL) and questions 19-20 were related to the patient's satisfaction with treatment. The first 18 questions were used to calculate the overall AFEQT score. The total AFEQT scores was calculated as 100 minus ([Sum of severity for all questions answered minus number of questions answered) divided by total number of questions answered*6])*100. The overall AFEQT scores ranged from 0 (complete disability) to 100 (no disability). Therefore, a positive change in score corresponded to improvement in QoL.
Time frame: Baseline, and 12 months post catheter insertion on Day 0
Change from baseline in overall AFEQT total score were reported. Change in the AFEQT score included 20 questions on a 7-point Likert scale. Questions 1-18 evaluated HRQoL and questions 19-20 were related to the patient's satisfaction with treatment. The first 18 questions were used to calculate the overall AFEQT score. The total AFEQT scores was calculated as 100 minus ([Sum of severity for all questions answered minus number of questions answered) divided by total number of questions answered*6])*100. The overall AFEQT scores ranged from 0 (complete disability) to 100 (no disability). Therefore, a positive change in score corresponded to improvement in QoL.
Biosense Webster, Inc.
Industry
Assessment of Safety and Effectiveness in Treatment Management of Atrial Fibrillation With the BWI IRE Ablation System (AdmIRE)
Acronym: AdmIRE
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05820295
Arrhythmias, Cardiac, Atrial Fibrillation
New York, United States
View Trial DetailsNCT05993897
Arrhythmias, Cardiac, Atrial Fibrillation
Aswān, Aswan Governorate, Egypt
View Trial DetailsNCT05357690
Arrhythmias, Cardiac, Atrial Fibrillation
Rochester, Minnesota, United States
View Trial DetailsNCT05164718
Arrhythmias, Cardiac, Atrial Fibrillation
Drammen, Norway
View Trial Details