Skip to main content
OpenTrials
Completed

NCT Number: NCT04014946

Assessment of Risk Factors for Appropriate ICD (Implantable Cardioverter-defibrillator) Intervention in Patients With Ischemic Cardiomyopathy

Design: PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (left ventricular) function assessed on local standards, of ischemic origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation.

General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).

Hypothesis: The primary alternative hypothesis states that the mean relative infarct transmurality (RIT) is different in patients with (RITshock or ATP (Anti Tachy Pacing)) and without (RITno shock or ATP )appropriate ICD intervention, i.e. shock or ATP.

* Null hypothesis (H0): RITshock or ATP = RITno shock or ATP * Alternative hypothesis (Ha): RITshock or ATP ≠ RITno shock or ATP

Sample size: 200 patients.

Follow-up: Enrolment visit, pre implant screening, ICD implantation, pre-hospital discharge visit, and follow-up (FUP) visits at 2, 6, 12, 18, 24 months including home monitoring. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–85 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

About this study

Rationale: Implantation of an ICD as primary prevention therapy is indicated according to the current guidelines based on the low LVEF (Left Ventricular Ejection Fraction) as it was shown to significantly reduce mortality. Although of proven efficacy, ICD therapy is associated with survival benefit in only a small fraction of patients. It is estimated that 18 patients would have to receive an ICD to save one life, resulting in a huge burden on national health systems. Moreover, only about one quarter of all guideline eligible primary prevention ICD patients receive appropriate shocks. The above considerations support the need for an effective risk-stratification method to identify patients that benefit most (or least) from this therapy. Evaluation of ventricular anatomy and function by imaging techniques has become more important since this provides information on the substrate (myocardial scar) and trigger of life-threatening ventricular arrhythmias. Besides accurate estimation of left and right ventricular volumes and functions, Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging has a very high sensitivity to detect myocardial scar. Quantification of scar characteristics by cardiac MRI might be useful for the prediction of future arrhythmic events in patients with ischemic cardiomyopathy. However evidence is conflicting and published papers are hampered by limited patient numbers and can only be regarded in the light of generating hypothesis. The PARCADIA clinical investigation will explore the potential of cardiac MRI as a predictor for appropriate ICD intervention in a multicenter setting.

PARCADIA is a prospective non-randomized non-interventional multi-center clinical investigation in Europe. Patients with depressed LV (Left Ventricular) function assessed on local standards, of ischemic (at least 40 days post-MI (myocardial infarction) or 3 months post revascularization) origin and on chronic optimal medical therapy will be selected according to inclusion and exclusion criteria, implanted with an ICD after executing baseline investigations and prospectively followed up for minimal 24 months and until the termination of the clinical investigation

General objective: analysis of baseline risk factors to identify predictors for appropriate ICD intervention in patients with ischemic cardiomyopathy receiving an ICD for primary prevention (MADIT II population).

The primary objective of the clinical investigation is to determine whether there is a relationship between appropriate ICD intervention (shock or ATP) and the Relative Infarct Transmurality (RIT) obtained from Late Gadolinium Enhanced Cardiac Magnetic Resonance (LGE-CMR) imaging in patients with ischemic cardiomyopathy, receiving an ICD for primary prevention.

Methodology: Screening: (within 6 months before enrolment) patients with LV depressed function due to Ischemic Cardiomyopathy with an indication for primary prevention ICD implantation according to ESC (European Society of Cardiology) guidelines or local standards will be screened within 6 months before enrolment.

pre implant diagnostics: within 3 months after enrolment LGE-CMR imaging, 24h holter, 12-lead ECG, will be performed and biochemical markers will be obtained.

ICD implantation: Implantation of a Lumax 540 single/dual chamber ICD or successor withiin 3 months after enrolment. The ICD will be programmed according to protocol.

Pre-hospital discharge an ICD interrogation wil be performed. Follow-up (FUP) visits at: 2, 6, 12, 18, 24 months with inclusion of standard 12-lead ECG, ICD check-up and cardiologist visit in the outpatient clinic. Additional routine FUP every 6 months until study termination after last enrolled patient has completed 2 years FUP.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patient with ischemic cardiomyopathy indicated for a de novo ICD implantation for primary prevention, according to ESC guidelines or local standards (MADIT II population)
  • Written informed consent / willingness and ability to comply with the protocol

Exclusion criteria

  • Contraindication for MRI
  • Severe renal dysfunction (stage 4 or 5) resulting in contra-indication for the admission of gadolinium during MRI (See Appendix A for more details)
  • Indication for secondary prevention ICD implantation
  • Class I indication for cardiac resynchronization therapy
  • Heart failure with New York Heart Association functional class IV
  • LV ejection fraction >40%
  • Age <18 years and >85 years
  • Women that are pregnant, lactating or planning to become pregnant
  • Participating in any other clinical trial with active intervention(s) during the course of this study
  • Life expectancy less than 1 year

Treatment and study plan

ICD implantation

Device

implantation of the Lumax 540 single/dual chamber ICD or successor

Other names: Lumax 540 single/dual chamber ICD or successor

Primary outcomes

  1. Relative Infarct Transmurality

    Time frame: Measured during Late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) imaging within 3 months after inclusion and before ICD implantation

    Percentage Relative Infarct Transmurality (RIT = transmural infarct mass / total infarct mass) obtained from LGE-CMR

  2. appropriate ICD intervention (shock or ATP)

    Time frame: Until the 24 month follow-up

    assessment whether patient had appropriate ICD intervention (shock or ATP) or not during 24 months follow-up. ICD interventions will be labeled appropriate or non-appropriate by an independent endpoint committee.

Secondary outcomes

  1. LV function (EF)

    Time frame: Baseline

    Left Ventricular function (Ejection Fraction in %) measured during LGE-CMR at baseline before ICD implantation

  2. LV mass

    Time frame: Baseline

    LV mass measured during LGE-CMR at baseline before ICD implantation

  3. total infarct mass

    Time frame: Baseline

    total infarct mass measured during GGE-CMR at baseline before ICD implantation

  4. transmural infarct mass

    Time frame: Baseline

    transmural infarct mass measured during LGE-CMR at baseline before ICD implantation

  5. mean Heart Rate (HR)

    Time frame: Baseline

    mean HR measured by 24-hrs Holter

  6. Day and night HR

    Time frame: baseline

    Day and night HR measured by 24-hrs Holter

  7. spontaneous episodes of atrial and ventricular arrhythmias

    Time frame: baseline

    number of spontaneous episodes of atrial and ventricular arrhythmias measured by 24-hrs Holter

  8. heart rate variability (SDNN: Standard deviation of consecutive normal-to-normal intervals)

    Time frame: baseline

    heart rate variability (SDNN) measured by 24-hrs Holter

  9. HR

    Time frame: baseline

    HR on 12 lead ECG

  10. rhythm

    Time frame: baseline

    rhythm on 12 lead ECG

  11. QRS width

    Time frame: baseline

    QRS width on 12 lead ECG

  12. serum sodium and potassium

    Time frame: baseline

    concentration of serum sodium and potassium (in mmol/l ) (blood sample)

  13. serum creatinine

    Time frame: baseline

    concentration of serum creatinine (in umol/l) (blood sample)

  14. uric acid

    Time frame: baseline

    concentration of uric acid (in mmol/l) (blood sample)

  15. albumin

    Time frame: baseline

    concentration of albumin (in g/l) (blood sample)

  16. HbA1c (Hemoglobin A1c)

    Time frame: baseline

    concentration HbA1c (mmol/mol) (blood sample)

  17. NT-proBNP (N-terminal pro-hormone Brain Natriuretic Peptide)

    Time frame: baseline

    concentration NT-proBNP (in pg/ml) (blood sample)

  18. hsTNT/I (high sensitive Troponin-T/I)

    Time frame: baseline

    concentration hsTNT/I (in ng/ml) (blood sample)

  19. aldosterone

    Time frame: baseline

    concentration aldosterone (in pmol/l) (blood sample)

  20. incidence of hypertension

    Time frame: baseline

    Baseline clinical demographics: hypertension in clinical history

  21. incidence of diabetes

    Time frame: baseline

    Baseline clinical demographics: diabetes in clinical history

  22. incidence of hypercholesterolemia

    Time frame: baseline

    Baseline clinical demographics: hypercholesterolemia in clinical history

  23. PVC/hr: Premature ventricular contraction per hour

    Time frame: baseline

    PVC/hr: Premature ventricular contraction per hour on 24hrs Holter

Sponsors and collaborators

Lead sponsor

Biotronik SE & Co. KG

Industry

Registry information

Official study title

Prospective Assessment of Risk Factors for Appropriate ICD Intervention in Patients With Ischemic Cardiomyopathy

Acronym: PARCADIA

Important dates

Study start
2012
Primary completion
2020
Study completion
2020
First posted
Jul 10, 2019
Registry last updated
Sep 29, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.