Rakesh K
Hyderabad, Telangana, 500082, India
NCT Number: NCT03324074
Pylorus is a tubular structure which contains circular muscle, forming pyloric sphincter which separates stomach and duodenum. The motor activity of the pyloric sphincter is less investigated. Antroduodenal manometry is an invasive and time consuming technique also limited by inability to measure compliance of the sphincter.
Recently, a new technique functional lumen imaging probe (FLIP) which is based on principle of impedance planimetry (IP). The endoluminal FLIP (EndoFLIP) EF -100 system uses a multi-detector IP system to produce a 3-dimensional outline of a sphincter. EndoFLIP can measure tissue distensibility and geometric changes through volumetric distention with real-time images. The esophagogastric junction (EGJ) has been well studied using EndoFLIP, studies for assessment of pyloric function are lacking.
Looking for future studies?
Notify Me18 year–60 year
All sexes
Observational
Hyderabad, Telangana, 500082, India
Objective:
To evaluate the motor activity of pyloric sphincter using Endo FLIP in the form of pressure, diameter, cross-sectional area (CSA) and distensibility in the healthy volunteers.
Methods 20 healthy volunteers will be recruited by local advertising, hospital staff and hospitalised patient's relatives. They will be screened for evidence of organic or functional gastrointestinal disorders, if found to have any will be excluded. Subjects on any medication that is known to affect gastrointestinal function will be excluded.
EndoFLIP method
The subjects will be fasting for at least 8 hours prior to the study. The study will be performed under sedation using monitored anesthesia using propofol in the left lateral decubitus position. Initial endoscopic examination will be performed up to the antrum without traversing the pylorus using (160 Olympus).An EndoFLIP catheter will be passed through biopsy channel into pylorus under direct endoscopic and fluoroscopic visualization.
Pylorus will be assessed using EndoFLIP at 20, 30, 40 and 50 cc balloon volume distentions. Pressure will be measured by pressure transducer inside the balloon. CSA will be measured using impedance planimetry by Ohm's Law. Distensibility will be calculated as minimum CSA divided by pressure at each balloon fill volume. These measurement will be assessed after the balloon inflated at each balloon distension for minimum of 5 seconds. The length of the pylorus will be assessed visually from EndoFLIP images. Once the EndoFLIP measurements completed at rest, Injection hyoscine 10mg intravascular will be administered, and same measurements will be repeated. Thereafter remaining endoscopic exam will be completed.
This is an observational study with no intervention.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 1 day
To evaluate the pyloric sphincter pressure using EndoFLIP in the healthy volunteers.
Time frame: 1 day
To evaluate the pyloric sphincter diameter using EndoFLIP in the healthy volunteers.
Time frame: 1 day
To evaluate the pyloric sphincter cross-sectional area using EndoFLIP in the healthy volunteers.
Time frame: 1 day
To evaluate the pyloric sphincter distensibility using EndoFLIP in the healthy volunteers.
Asian Institute of Gastroenterology, India
Other
Assessment of Pyloric Sphincter Physiology Using EndoFLIP
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.