Escuela Universitaria de Fisioterapia de la ONCE
Madrid, 28034, Spain
Location status: Recruiting
Location contact
Irene Rodríguez-Andonaegui, Lecturer
CONTACT
+0034915894500 ext. 4389
Susana García-Juez, Lecturer
CONTACT
+0034915894500 ext. 4496
NCT Number: NCT03675087
This study evaluates the correlation between the 6-min walking test (6MWT) with gases measurement, and the peak cardiopulmonary exercise testing (CPET) using incremental cycling with gases and workload measurement, in order to determine if the 6MWT detects impairment in exercise tolerance and if it avoids the post-exertional malaise that the peak CPET causes on decreasing levels of physical activity, in participants affected by chronic fatigue syndrome/ myalgic encephalomyelitis (CFS/ME).
Physical activity level at baseline (usual activity, the parcipant will not be given any directions) will be recorded during 7 days, 24 hours/day. Afterwards, the 6MWT will be performed. After this test, the physical activity level will be collected again during 7 days, 24 hours/day. Peak CPET will be carried out 14 days after 6MWT to make sure that the basal levels are recovered, and finally, physical activity level will be collected again during 7 days, 24 hours/day.
Interested in participating?
Request Info18 year–65 year
All sexes
Observational
Madrid, 28034, Spain
Location status: Recruiting
Irene Rodríguez-Andonaegui, Lecturer
CONTACT
+0034915894500 ext. 4389
Susana García-Juez, Lecturer
CONTACT
+0034915894500 ext. 4496
Chronic fatigue syndrome/ myalgic encephalomyelitis presents with a significant deterioration of functional capacity, which seriously affects the quality of life. The peak or maximal incremental CPET is considered valid for the evaluation of exercise tolerance of those affected by CFS/ME, but its performance causes worsening of its symptomatology, decreasing its physical activity level after the test. It has not been verified whether the 6MWT (submaximal exercise test) with gases measurement is able to assess the exercise tolerance of those affected by SFC/EM without increasing their symptoms. So far, only the correlation between another submaximal test and a peak CPET in two different groups of participants have been analyzed and proven, which it makes necessary to check adequately whether there is a correlation by performing both tests on the same participants. In addition, it is necessary to compare the degree of worsening in physical activity level that both tests produce in participants, because they have not been objectively evaluated in any previous study. It could be useful to have a more innocuous and simple test for the assessment of exercise tolerance in CFS/ME in clinical practice, in order to evaluate the benefits of treatments like rehabilitation programs. 6MWT could respond to these characteristics because it reaches an identical value in peak VO2 than in the peak CPET in other pathologies and it generates less physical stress.
This research will be developed with the utmost respect for individual human rights, according to the postulates accepted internationally by the United Nations and the European Commission (Helsinki Act of 1964 and the Oviedo Convention of 1997) and Regulation (EU) 2016/679 of the European Parliament and the Council of April 27, 2016 on Data Protection (RGPD).
Participation in this study is entirely voluntary and does not imply any risk to health. Participants are entitled to refuse to participate or to leave the study at any time they choose.
All information will be treated confidentially. If it is decided to publish the results of the study, in these publications will not include individual data or the names of the participants, only information considered globally will be included.
This study has been approved in August 2018 by the Ethics and Research Committee of the La Paz University Hospital in Madrid (HULP Code: PI-3320).
The sample sizes were calculated in order to find the significance of the Pearson linear correlation coefficient between two variables, for a unilateral hypothesis test according to the formula: n = [Z1-α + Z1- β / ½ ln (1 + r / 1-r)]^2 + 3 and the largest has been chosen, which involve studying 22 participants.
Taking into account the data of a previous study with participants of similar characteristics, a correlation of the parameters that set up the primary outcome, peak VO2 of r = 0.7 is assumed.
An expected drop out in rate of 0.474 has been estimated from the data obtained in another related study.
Accepting an alpha risk of 0.05 and a beta risk of 0.20 in a unilateral contrast, 22 participants are required to detect a positive correlation between the variables of the exercise tests, equal to or greater than those found in the study used as reference.
This size will guarantee sufficient power to detect correlation in the purpose of the study. To guarantee this power, and since there is not enough information about the previous values, an intermediate analysis of the data, will be carried out in the middle of the study to recalculate the size of the final sample.
The incidental sampling will be carried out according to a non-probabilistic system of consecutive cases of people diagnosed with CFS/ME.
Data analysis / Statistical methods:
In case of drop out, the data collected will be taken into account for the analysis.
The analysis will assume a confidence level (1 - α) of 0.95 (significance level α = 0.05). The program SPSS® Statistics version 20.0 (SPSS Incorporation, Chicago, USA) will be used.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 3 hours one day and 2 hours another day.
The portable spirometer Oxycon Mobile CPET from JaegerTM during 6MWT or the fixed spirometer Mijnhart Oxycon during peak CPET will be used for its measuring. Those instruments are validated. Mean and standard deviation will be calculated.
Time frame: 5 minutes.
It will be measured with the date of birth, collected by data collection sheet. Mean and standard deviation will be calculated.
Time frame: 5 minutes.
It will be collected by data collection sheet. The percentage by gender will be calculated.
Time frame: 5 minutes.
Profession is an open field, works, with or without salary. It will be collected by data collection sheet. The percentage by profession will be calculated.
Time frame: 5 minutes.
It will be measured from the date of medical diagnosis. It will be collected by data collection sheet. Mean and standard deviation will be calculated.
Time frame: 5 minutes.
Options yes or not, presence of orthostatic postural tachycardias and/or alterations in the Heart Rate Variability. It will be collected by data collection sheet. Percentage of participants with or without autonomic dysfunction will be calculated.
Time frame: 10 minutes.
The type of medications consumed is an open field. It will be collected by data collection sheet. Percentage by name of medication will be calculated.
Time frame: 5 minutes.
It will be measured with the Pesperson precision scale. Range 200 grams-160 kilograms. Sensitivity 100 grams. Mean and standard deviation will be calculated.
Time frame: 5 minutes.
It will be measured with the Pesperson tape height meter, range 82-200cm. Sensitivity 1mm. Mean and standard deviation will be calculated.
Time frame: 5 minutes.
It is calculated by dividing the weight by the square of the height with the data obtained by the two previous outcomes. Mean and standard deviation will be calculated.
Time frame: 7 days.
The time that participant spends lying, sitting, standing or walking is measured 7 days, 24 hours/day before both exercise tests. It will be registered with the activity meter ActivPAL4 micro, which is validated as an instrument for detecting the activity and as a tool for estimating energy expenditure, and whose data are reproducible. Mean and standard deviation will be calculated.
Time frame: 15 minutes.
It will be performed according to the American Thoracic Society protocol with three forced spirometries The portable spirometer Oxycon Mobile CPET from JaegerTM will be used for its measuring. Mean and standard deviation will be calculated.
Time frame: 15 minutes.
It will be performed according to the American Thoracic Society protocol with three forced spirometries. The portable spirometer Oxycon Mobile CPET from JaegerTM will be used for its measuring. Mean and standard deviation of FEV1 will be calculated.
Time frame: 15 minutes.
It is calculated with the data provided by the two previous outcomes. Mean and standard deviation will be calculated.
Time frame: 10 minutes on day and 10 minutes another day.
Open field, daily medications dosage consumed before and after both tests. It will be collected by data collection sheet. Mean and standard deviation of the differences in the dose intake by type of medication will be calculated.
Time frame: 20 minutes one day and 20 minutes another day.
It is measured from 0 to 100 points by the SF-36v2 (internal consistency value α of Cronbach of 0.94). This instrument provides a profile of health status, it is usually used in studies of research in the international field in the SFC/EM and a validated version is available in Spanish. Mean and standard deviation of the differences in the total questionnaire score and in the subscales of the questionnaire will be calculated.
Time frame: 10 minutes one day and 10 minutes another day.
It is measured from 4 to 20 points with the Multidimensional Inventory of Fatigue in Spanish (MIF: S) (internal consistency value α of Cronbach of 0.91). Mean and standard deviation of the differences will be calculated.
Time frame: 21 days, in 3 periods of 7 days.
The mean change in values of the time that participant spends lying, sitting, standing or walking is measured 7 days, 24 hours/day before both exercise tests and 7 days, 24 hours/day after the 6MWT and after the peak CPET. It will be registered with the activity meter ActivPAL4 micro, which is validated as an instrument for detecting the activity and as a tool for estimating energy expenditure, and whose data are reproducible.
Time frame: 3 hours one day and 2 hours another day.
The portable spirometer Oxycon Mobile CPET from JaegerTM during 6MWT or the fixed spirometer Mijnhart Oxycon during peak CPET will be used for its measuring. Those instruments are validated. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
Class 1, 2, 3 or 4, classification of the impairment in exercise tolerance of the American Medical Association that is based on the values of percentage of peak VO2 body weight adjusted achieved during the exercise tests in accordance with the values of overall population. Percentage of participants in each class will be calculated.
Time frame: 3 hours.
It will be obtained by the 6MWT with the American Thoracic Society protocol. Mean and standard deviation will be calculated.
Time frame: 2 hours.
It is measured through the Jaeger 900 cycle ergometer during the peak CPET with Snell CR. et al protocol. Mean and standard deviation of participants´ peak work load will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It is measured in percentage with a portable spirometer Oxycon Mobile CPET of JaegerTM in the 6MWT or with a fixed spirometer Mijnhart Oxycon in the peak CPET. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It is measured in beats per minute with the heart rate sensor of the Polar TM31 band in 6MWT or with the 12-lead JaegerTM ECG in the peak CPET. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It is measured in beats per minute with the heart rate sensor of the Polar TM31 band in the 6MWT or with the 12-lead JaegerTM ECG in the peak CPET. Mean and standard deviation of the differences in hearth rate between baseline and after the 6MWT or peak CPET will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It is measured in mmHg with Suntech Oscar 2 tensionmeter in the 6MWT or Riester tensionmeter in the peak CPET. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It will be measured in milliseconds, standard deviation of all the variations in the time interval between heartbeats measured with the heart rate sensor of the TM31 Polar band in the 6MWT or with the 12-lead JaegerTM ECG in the peak CPET. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It will be calculated with the value of the maximum heart rate reached and the maximum theoretical heart rate (220-patient's age) in the 6MWT and in the peak CPET. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It is measured in millilitres/ minute with a portable spirometer Oxycon Mobile CPET of JaegerTM in the 6MWT or with a fixed spirometer Mijnhart Oxycon in the peak CPET. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It is measured in millilitres/ minute /kilograms with a portable spirometer Oxycon Mobile CPET of JaegerTM in the 6MWT or with a fixed spirometer Mijnhart Oxycon in the peak CPET. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It will be measured in millilitre/ cycle with a portable spirometer Oxycon Mobile CPET of JaegerTM in the 6MWT or with a fixed spirometer Mijnhart Oxycon in the peak CPET. Mean and standard deviation in differences in oxygen pulse at baseline and at peak VO2 in both exercise tests will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It will be measured in millilitre/ min with a portable spirometer Oxycon Mobile CPET of JaegerTM in the 6MWT or with a fixed spirometer Mijnhart Oxycon in the peak CPET. Mean and standard deviation in differences in CO2 production between baseline and peak VO2 in both exercise tests will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It will be measured in millilitres/ minute, is calculated with the values of O2 consumption and CO2 production before tests and at peak VO2 of both exercise tests. Mean and standard deviation will be calculated.
Time frame: 3 hours one day and 2 hours another day.
It will be measured in litres/ minute with a portable spirometer Oxycon Mobile CPET of JaegerTM in the 6MWT or with a fixed spirometer Mijnhart Oxycon in the peak CPET. Mean and standard deviation of differences between baseline and at peak VO2 of both exercise tests will be calculated.
Contact information is provided by the study sponsor or research team.
Escuela Universitaria de Fisioterapia de la Once
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06472622
Chronic Disease, Disease Attributes
Bethesda, Maryland, United States
View Trial DetailsNCT04049331
Chronic Disease, Disease Attributes
Boston, Massachusetts, United States
View Trial DetailsNCT07637084
Cardiovascular Diseases, Chronic Disease
Boulogne-Billancourt, Île-de-France Region, France
View Trial DetailsNCT07491315
Cardiovascular Diseases, Chronic Disease
Marseille, France
View Trial Details