University of Baghdad College of Dentistry
Baghdad, Iraq
NCT Number: NCT06124235
Aim To compare between orthodontic miniscrews coated and uncoated with CHX- HMP NP nanoparticles.
Looking for future studies?
Notify Me13 year and older
All sexes
Interventional
Phase 3
Baghdad, Iraq
Anchorage management by using of OMS to give anchoring for force application made using several orthodontic treatment techniques simple and improved their efficacy , because anchorage control is a challenge throughout the orthodontic treatment process till temporary orthodontic anchorage devices have been developed. Although stainless steel (SS) screws were initially introduced, the majority of currently presented OMS are manufactured from titanium (purity grades I to IV). Because they offer greater mechanical strength and reduce the danger of fracture during insertion and removal, titanium alloy miniscrews are typically employed. Failure of these devices is the most frequent issue related to the usage of OMSs. The development of a biofilm on these devices that causes periimplantitis is one of the recognized reasons for failure.
Primary stability (mechanical stability) is awarded shortly after the placement procedure of the device and secondary stability (biological stability) initiates at the placement time and enhances during the process of healing or bone remodeling. The first 8 weeks after insertion, during which time the stability of the implant transitions from mechanical to biological stability, are when OMS failure occurs most frequently. Although failure might be prevented by following the right protocols of treatment, the fact that, rate of failure of OMS could not be overlooked. The miniscrew's mobility and displacement, together with an infection of the soft tissues around, are causes of failure. Unmodified titanium and its alloys are prone to bacterial infections which lead to inflammation and failure of the implant eventually. Prevention of bacterial adhesion may inhibit biofilm formation.
Antibiotics used for protection against implant infection postoperatively is debatable due to inducing the process of antimicrobial resistance, substitute techniques to avoid this must be inspected. There are three recent solutions that have the ability to prevent the formation of biofilm on miniimplant surfaces. These include altering the topography of surfaces to prevent bacterial adhesion, treating surfaces with antimicrobial releasing agents for a set period of time to prevent bacterial adhesion, as well as eliminating bacteria nearby, and, finally, coating surfaces with antimicrobial agents that prevent attachment of bacteria over an extended period of time. The previous study on human dermal fibroblast of neonate cells showed that both coated and uncoated titanium OMSs were non-cytotoxic, furthermore, the animal study showed enhanced bone-remodeling process.
The research question is 'Does coating orthodontic mini-screws with CHX-HMP NPs increase their success rate?
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
insertion:
The miniscrews used conical shaped, self-drilling, 1.6 mm in diameter, 8mm in length made of Ti.
Non-coated orthodontic miniscrews
Time frame: for 4 month.
Orthodontic mini-screw will be considered successful when it could be loaded with orthodontic forces and fulfill its anchorage objectives without pain, gingival growth cover the head of miniscrew and fracture of miniscrew.
Time frame: each month for 3 month.
The absence versus presence of peri-implantitis was evaluated by means of periodontal visual inspection. When the keratinized gingiva were normal (i.e., they had a pink color, no edema or tissue growth, and no spontaneous bleeding), they were given a score of 0 (absence of peri-implantitis). A score of 1 was used to indicate mild peri-implantitis (i.e., the keratinized gingiva around the MI exhibited a color alteration, with a small volumetric increase, but not covering the MI head base, and without spontaneous bleeding. A score of 2 was used to indicate severe peri-implantitis, with the keratinized gingiva showing a color change, spontaneous bleeding, and gingival hyperplasia covering the MI head base. Finally, larger gingival hyperplasia covering part or all of the MI's head were given a score of 3. Normally, in the latter situation, the gingiva also presented with a color change and spontaneous bleeding.
Time frame: 1 day, 2 day, 3 day, 4 day, 5 day, 6 day, and 7 day.
The patients will be given a sheet contain VAS scale and will be informed about how to use it. They will be told that zero in VAS corresponds to no pain and 10 corresponds to maximum pain, and will be asked to document their perceived pain intensity accordingly. Pain perception will be recorded after TAD insertion by 1 day, 2 day, 3 day, 4 day, 5 day, 6 day, and 7 day.
Time frame: each month for 3 month.
MI mobility was classified using 4 scores: a score of 0 was given when there was no movement of the MI. When there was a small amount of mobility of the MI, but without tissue ischemia, it was classified with score of 1 (exhibiting mobility but fulfilling its function). Moderate displacement of the MI causing tissue ischemia was classified with score of 2 (exhibiting displacement but fulfilling its function). Finally, a score of 3 was used when mobility was excessive, to the point of preventing the MI from maintaining anchorage.
University of Baghdad
Other
Assessment of Coated Orthodontic Miniscrews With Chlorhexidine Hexametaphosphate Antimicrobial Nanoparticles (A Randomized Clinical Trial)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07698730
Orthodontic Appliance Complication
Can Tho, Vietnam
View Trial DetailsNCT06814262
Orthodontic Appliance Complication
Richmond, Virginia, United States
View Trial DetailsNCT07546058
Orthodontic Appliance Complication
Latakia, Latakia Governorate, Syria
View Trial DetailsNCT06416904
Orthodontic Appliance Complication
Cairo, Egypt
View Trial Details