Automatic closed-loop insulin delivery
DeviceSensor transmit glucose data every 5 minutes to the control algorithm which adjusts insulin delivery every 5 minutes.
NCT Number: NCT02366767
The overall aim of this research proposal is to determine the safety, feasibility and efficacy of an automatic closed-loop insulin delivery system.
Looking for future studies?
Notify Me14 year–40 year
All sexes
Interventional
Not applicable
Camp Conrad-Chinnock, Angelus Oaks, California, United States
This study will be completed in two parts.
The initial part of this study will be an inpatient evaluation of the system with the primary goal of assessing safety and feasibility. This will involve 8 subjects with type 1 diabetes, aged 14 - 40 years, admitted for up to 60 hour. Plasma glucose levels will be collected hourly and tested by YSI (YSI 2300, Yellow Springs Instrument). These studies will be performed at Stanford University and will include group sporting activities to mimic the diabetes camp environment. Capillary blood glucose testing will be performed every 2-3 hours before meals, snacks, exercise, and prebed by subjects with research staff supervision during the day and at 00:00, 03:00 and 07:00 by research staff. These data will be reviewed by the DSMB before proceeding to camp studies.
The second part of this study will be to test the efficacy of the system during diabetes summer camps. We will test the system in subjects with type 1 diabetes, aged 14-40 years, attending diabetes camp. There will be 20 subjects recruited, with 10 subjects randomized to the control arm Medtronic 530G system with threshold suspend (control group) and 10 subjects randomized to the automatic closed-loop insulin delivery (intervention group). Capillary blood glucose testing will be performed every 2-3 hours before meals, snacks, exercise and prebed by subjects with research staff supervision and at 00:00, 03:00 and 07:00 by research staff. The primary aim of this study is to generate preliminary data of system safety and efficacy in a closely supervised environment that challenges glucose control.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Sensor transmit glucose data every 5 minutes to the control algorithm which adjusts insulin delivery every 5 minutes.
Threshold suspend
Other names: 530G Pump
Time frame: 6 days
Time frame: 6 days
Time frame: 6 days
As measured by overall mean sensor glucose percent time in range 70-180 mg/dL.
Stanford University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06238778
Autoimmune Diseases, Diabetes Mellitus
Huntington Beach, California, United States
View Trial DetailsNCT06236256
Autoimmune Diseases, Diabetes Mellitus
Ramat Gan, Israel
View Trial DetailsNCT07711275
Autoimmune Diseases, Diabetes Mellitus
Istanbul, Turkey (Türkiye)
View Trial DetailsNCT03938324
Anemia, Anemia, Hemolytic
Durham, North Carolina, United States
View Trial Details