Skip to main content
OpenTrials
Completed

NCT Number: NCT04285840

Arterial Versus Venous Activated Clotting Time (ACT) Measurements During Atrial Fibrillation Ablations

Activated clotting times (ACTs) are routinely measured throughout atrial fibrillation ablations to monitor anticoagulation prior to and after heparin administration. Routinely, ACTs are obtained from an arterial line established prior to heparin administration. With technological advances, the cardiac intervention team is interested in eliminating the need for arterial lines for noninvasive monitoring devices; eliminating arterial lines could decrease the risk of bleeding, infection, and pain. Since procedural access requires femoral vein catheterization, obtaining ACTs through the venous sheath would not pose additional risks to the patient. In this study it proposed to draw paired arterial and venous ACT samples in ablation procedures to compare the agreement between venous and arterial ACTs for adequate patient treatment planning.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Duke Health Raleigh

Raleigh, North Carolina, 27609, United States

About this study

This project aims to establish a standardized procedure for venous ACT sampling during atrial fibrillation ablation in 50 adults. Analyses will examine the relationship and agreement between venous and arterial ACTs. It is anticipated that the standardized procedure could eliminate the need for an arterial line for ACT measurement which would reduce patient risks for bleeding, infection, and discomfort.

Patients who are scheduled for for atrial fibrillation ablations will be invited to participate in this project. An information sheet will be provided about the project to potential participants. If the potential participant expresses interest, a study specific consent consent will be obtained to allow the additional paired blood samples to be drawn throughout the procedure. The additional blood volume to be drawn is expected to be less than or equal to a teaspoon of venous blood. Participation will be completely voluntary.

Patients will undergo usual standard of care for the procedure, including usual arterial and venous sheath/catheter insertions. After obtaining venous and arterial access, baseline ACTs will be drawn using the outlined ACT sampling procedure. The ACT value for both arterial and venous samples will be obtained using the standard procedure for Hemochron Signature Elite point-of-care testing; this test uses less than 0.5 cc blood. ACT samples will be performed at baseline (pre-heparin administration), every 30 minutes during the procedure (per standard ACT monitoring protocol to obtain and maintain desired ACT), and at the end of procedure prior to arterial and venous sheath removal. Time of procedure ranges from 2 to 4 hours and may result in a minimum of 2 paired samples (pre and end) to a maximum of 9 paired samples (pre, end, and every 30 minutes) per patient; this equates to an additional 1 cc to 4.5 cc of additional blood for paired sampling per patient.

ACT arterial and venous sampling procedure: Using a stopcock at the nearest point of insertion, withdraw 30 cc of blood in a syringe; turn the stopcock and remove 0.5cc of blood for ACT testing; turn the stopcock to return the 30 cc blood and flush the line; remove the syringe with the ACT sample and flush the line with saline, replace syringes for the next ACT sampling process.

Patients undergoing atrial fibrillation ablations will continue to have Heparin dosed on the arterial ACT sample results only per the standard of care. Heparin will not be administered based on venous ACT levels obtained during this project. The purpose for paired sampling is to verify that the proposed venous sampling method is accurate and provides an evaluable sample to compare with the ACT sample results.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

Adult scheduled for routine atrial ablation procedure

Exclusion criteria

None

Treatment and study plan

Venous ACT

Other

Matched/paired venous ACT samples will be drawn at the same time as arterial ACT samples to compare the results agreement between venous and arterial ACTs. Subjects undergoing atrial fibrillation ablations will continue to have Heparin dosed on the arterial ACT sample results only per the standard of care. Heparin will not be administered based on venous ACT levels obtained during this study.

Primary outcomes

  1. Proportion of venous ACT samples that match arterial ACT sample results during atrial fibrillation ablation

    Time frame: Day of atrial fibrillation ablation procedure

    Paired samples pre and during the ablation procedure

Sponsors and collaborators

Lead sponsor

Duke University

Other

Registry information

Official study title

Arterial Versus Venous Activated Clotting Time Measurements During Atrial Fibrillation Ablations

Important dates

Study start
2020
Primary completion
2020
Study completion
2020
First posted
Feb 26, 2020
Registry last updated
Jun 28, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.