Skip to main content
OpenTrials
Completed

NCT Number: NCT05648643

Arterial Elastance: A Predictor of Hypotension Due to Anesthesia Induction

Hypotension is very common during and after anesthesia induction. A prolonged fasting period, a patient's underlying comorbidities, a sympathetic blockade by anesthetic agents, vasodilation, a reduction in preload, and cardiac contractility can cause post-induction hypotension.1,2 The relationship of even short-term hypotension with myocardial damage, renal injury, and stroke has been shown in many studies; therefore, it is very important to provide stable anesthesia induction.3 In current anesthesia practice, we can only intervene when hypotension occurs. If we can identify patients who may experience hypotension during anesthesia induction before it occurs, we can prevent possible postoperative organ dysfunctions by reducing the duration and depth of hypotension with prophylactic fluid and vasopressor administration. We hypothesized that arterial elastance (Ea) values before anesthesia induction could predict post-induction hypotension. To test our hypothesis, we aimed to investigate the reliability of the Ea value, which was monitored preoperatively using the pressure analytical recording method (PRAM) to predict the risk of hypotension that may occur after anesthesia induction.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Acibadem Altunizade Hospital

Istanbul, 31190, Turkey (Türkiye)

About this study

Anesthesia induction-related hypotension is not uncommon and is still challenging for anesthesiologists to predict, despite advanced monitoring techniques. In current anesthesia practices, approximately 20-30% of patients develop hypotension during and after anesthesia induction. In large observational studies, the relationship between intraoperative hypotension and adverse cardiac, renal, and cerebral outcomes has been reported. Approximately one-third of intraoperative hypotension episodes occur during and after the induction of anesthesia, and most can be prevented if foreseeable. Therefore, we need quick and easy markers to predict patients at risk of hypotension to achieve the stable induction of anesthesia.

Many studies have used noninvasive and invasive monitoring techniques for the preoperative prediction of hypotension after anesthesia induction.

However, most studies evaluate the cardiovascular system with parameters that determine the preload and fluid responsiveness to predict the risk of post-induction hypotension, though the arterial system and its interaction with the ventricle are ignored.The heart and the arterial system are both anatomically and functionally interconnected and do not act independently. The major determinant of cardiovascular system performance and cardiac energetics is ventriculoarterial coupling (VAC). Ea is an indicator of cardiac afterload and arterial tone and can be calculated by the ratio of the end-systolic pressure (ESP) and stroke volume (SV) obtained from arterial wave analysis.Ea provides information about the ESP/SV relationship and dynamic afterload and gives the clinician the opportunity to evaluate VAC indirectly. We hypothesized that Ea values before anesthesia induction could predict post-induction hypotension. To test our hypothesis, we aimed to investigate the reliability of the Ea value, which was monitored preoperatively using the pressure analytical recording method (PRAM) to predict the risk of hypotension that may occur after anesthesia induction.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients with ASA( American Society Of Anesthesiology) physical status 1-3
  • Underwent major elective surgery
  • Required intra-arterial blood pressure monitoring before induction.

Exclusion criteria

  • Under 18 years of age
  • Arrhythmia (atrial fibrillation, frequent premature beat)
  • Severe pre-existing lung disease
  • Severe valvular heart disease
  • morbid obesity
  • emergency surgery

Treatment and study plan

Primary outcomes

  1. Arterial elastance (Ea) measured before anesthesia induction was investigated whether is a predictive parameter for post-induction hypotension in patients undergoing general anesthesia.

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Ea ((mmHg m-2ml-1)is an indicator of cardiac afterload and arterial tone and can be calculated by the ratio of the end-systolic pressure (ESP) and stroke volume (SV) obtained from arterial wave analysis. Ea was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy) before the anesthesia induction

Secondary outcomes

  1. Stroke volume variation (SVV), measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Stroke volume variation (SVV,%), was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). SVV is a parameter used to asses cardiac preload and fluid responsiveness

Other outcomes

  1. Pulse pressure variation (PPV), measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Pulse pressure variation (PPV,%) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). PPV is a parameter used to asses cardiac preload and fluid responsiveness.

  2. Cardiac power output (CPO), measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Cardiac power output (CPO, Watt) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). CPO is a parameter used to asses cardiac reserve

  3. Cardiac index (CI), measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Cardiac index (CI, L/min/m2), was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). CI is a parameter used to asses cardiac stroke volume

  4. Dp/Dt, measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Dp/Dt(mmHg/msn), was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). Dp/Dt is a parameter used to asses cardiac contractility.

  5. Systolic arterial pressure (SAP), measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Systolic arterial pressure (SAP- mm/Hg) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). SAP is a parameter used to assess the pressure of the arterial system during cardiac systole

  6. diastolic arterial pressure (DAP), measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Diastolic arterial pressure (DAP, mm/Hg) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). DAP is a parameter used to assess the pressure of the arterial system during cardiac diastole.

  7. mean arterial pressure (MAP), measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Mean arterial pressure (MAP, mm/Hg) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). MAP is a parameter used to assess organ perfusion.

  8. Heart rate (HR), measured before anesthesia induction were assessed for prediction of post-induction hypotension in patients undergoing general anesthesia

    Time frame: The duration of the study was defined from one minute before induction to 10 minutes after induction

    Heart rate (HR/bpm) was monitored using the uncalibrated pulse contour device MostCare (Vytech, Vygon, Padova, Italy). HR is a parameter used to assess the cardiac rate.

Sponsors and collaborators

Lead sponsor

Acibadem University

Other

Registry information

Important dates

Study start
2022
Primary completion
2022
Study completion
2022
First posted
Dec 13, 2022
Registry last updated
Dec 13, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.