Completed

NCT Number: NCT03651648

Apnea Treatment in Premature Infants Using an Automatic Vibro-tactile Stimulator Triggered by the Detection of Apnea-bradycardia.

The goal of the SENSITACT system is to activate an adaptive kinesthetic stimulation to treat apnea-bradycardia events on preterm infants, while minimizing deleterious effects, in particular arousals that can be due either to respiratory efforts or to kinesthetic stimulation itself. This novel system will provide an alternative treatment to apnea-bradycardia, with improved patient comfort and autonomy. In particular, it may become a complementary solution for the current treatments (Manual stimulation by caregivers, continuous or intermittent nasal positive pressure ventilation and methylxanthine therapies) that do not appear to be optimal and usually only allow a partial reduction in the number and severity of apneas.

Completed

Looking for future studies?

Notify Me

Key information

About this study

The main hypothesis behind the SENSITACT system is that kinesthetic stimulation can terminate apneas-bradycardias with minimal patient arousal. The aim is to stimulate mechanoreceptors through the skin by kinesthetic stimulation on the lower abdominal zone. This is a region of the body that is covered with Pacinian corpuscles, a very sensitive kind of mechanoreceptors, which respond to rapid vibrations on the skin (200-300 Hz). Vibro-tactile stimulation of these mechano-receptors will trigger a reaction typical of the startle reflex. This reflex causes 1) an immediate myotonic reaction and 2) a widespread autonomic response. The former should have a direct effect on obstructive respiratory disorders with an increase in chin muscle tones within 80 to 100 ms. The latter should act on central respiratory disorders, with activation of the sympathetic nervous system. Since both responses are mediated via sub-cortical nervous center, it is expected that patient arousal will be limited. Preliminary clinical studies on adult patients conducted by LTSI, Sorin CRM and CHU de Grenoble (Skin&SAS, HYPNOS, EKINOx), that have used the same PASITHEA stimulation device have confirmed activation of the sympathetic nervous system and a significant reduction in the duration of apnea or hypopnea events, while no differences were observed on patients' sleep architecture.

The SENSITACT system is able to detect apneas-bradycardias in real-time, so that kinesthetic stimulation can be triggered to stop respiratory disorders very early during the event. Detection is performed within the SENSITACT controller station that receives data from all sensors connected to the Patient Monitor in real-time. As soon as the early signs of an apnea-bradycardia are detected, the SENSITACT controller sends a trigger signal to the PASITHEA stimulator that immediately activates kinesthetic stimulation.

Kinesthetic stimulation is stopped when a normal condition (normal cardiac rhythm) is detected or when a maximum number of stimulation pulses have been reached.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • written informed consent,
  • Premature infants,
  • born to a term less than 34 weeks of amenorrhea (AS),
  • Age less than 36 weeks post-menstrual age,
  • With a postnatal age greater than 4 days,
  • caffeine treated, for at least 36 hours,
  • Presenting episodes of bradycardia apnea significant (>10 sec with bradycardia <100 bpm or SaO2<80%) with an interval of less than 6 hours between two episodes observed in the 24 hours preceding inclusion.

Exclusion criteria

  • Major congenital neurological abnormalities,
  • Congenital abnormalities of the respiratory tracts,
  • HIV grade 3 or 4,
  • Periventricular leukomalacia,
  • Invasive ventilation and non-invasive ventilation in NAVA mode,
  • Cyanogenic malformative heart disease,
  • Sepsis diagnosed in the 4 days prior to registration (CRP> 10mg / L),
  • maternal addiction during pregnancy,
  • Father and / or mother legally protected (under judicial protection, guardianship or supervision).

Treatment and study plan

SENSITACT System

Device

the activated stimulation (ON period of 6 hours) will be hidden from the care team, who will continue the care according to the usual procedures (blind treatment).

Other names: Actived stimulation

Primary outcomes

  1. Cumulative duration of apnea-bradycardia

    Time frame: 12 hours (H12)

    Cumulative duration of apnea-bradycardia over a period of 6 hours with stimulation activated or not.

Secondary outcomes

  1. Distribution of bradycardia durations

    Time frame: 12 hours (H12)

    A bradycardia is defined by an acute event lasting at least 5 seconds with a decrease in heart rate of more than 33% of the basal heart rate (median of heart measured on 5-min stationary periods during quiet sleep).

    The distribution of the durations will be quantified in terms of median, IQR and distribution curve

  2. Depth of bradycardia

    Time frame: 12 hours (H12)

    A bradycardia is defined by an acute event lasting at least 5 seconds with a decrease in heart rate of more than 33% of the basal heart rate (median of heart measured on 5-min stationary periods during quiet sleep).

    The depth of bradycardia will be measured by the area under the curve with the upper limit of the curve defined by the value of "basal heart rate-33%" and expressed in beats/min*sec The distribution of the depth of bradycardias will be quantified in terms of median, IQR and distribution curve

  3. Depth of desaturations

    Time frame: 12 hours (H12)

    The depth of desaturation will be measured by the area under the curve with the upper limit of the curve set at a Saturation of 80% The distribution of the depth of desaturations will be quantified in terms of median, IQR and distribution curve

  4. Caregiver interventions

    Time frame: 12 hours (H12)

    The number of caregiver interventions associated with a cardio-respiatory event will be quantified and expressed in number/hour

  5. Cardiorespiratory parameters in response to stimulation

    Time frame: 6 hours (H6)

    The delay between the initiation of stimulation and the first breath will be measured and expressed in median IQR The delay between the initiation of stimulation and the normalization of heart rate above the limit of "basal heart rate-33%" will be measured and expressed in median IQR The delay between the initiation of stimulation and the observation of a Saturation above 80% will be measured and expressed in median IQR

  6. Premature's sleep-wake cycles

    Time frame: 12 hours (H12)

    Duration of the stages identified

Sponsors and collaborators

Lead sponsor

Rennes University Hospital

Other

Registry information

Acronym: SENSITACT

Important dates

Study start
2019
Primary completion
2022
Study completion
2022
First posted
Aug 29, 2018
Registry last updated
Mar 30, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.