The DAShED (Diagnosis of Aortic Syndrome in the ED) Study
NCT05582967
Acute Aortic Syndrome, Aneurysm
Bath, United Kingdom
View Trial DetailsNCT Number: NCT02086136
Acute aortic dissection (AD) is a deadly, difficult to diagnose disease presenting with an array of common and unspecific symptoms. Aortic dissection detection (ADD) risk score is a bedside clinical tool to estimate the risk of AD. D-dimer has been evaluated in several studies as a biomarker of AD and has showed a pooled diagnostic sensitivity of 97%. However, considering the severe morbidity and mortality of AD, a negative d-dimer per se is considered insufficient to rule-out AD in unselected patients.
The aim of the present study is to evaluate whether the diagnostic performance of d-dimer differs in patients at different clinical risk of AD, and in particular whether a negative d-dimer test may allow safe rule-out of AD in any patient subgroup without necessity to perform urgent aortic imaging.
Consecutive adult patients with suspected AD presenting to Emergency Department will be enrolled before the establishment of a final diagnosis; a standardized clinical form comprehensive of presence/absence of 12 risk markers allowing ADD risk score fulfilled and d-dimer levels measured at presentation.
The aortic imaging exam used to confirm or refuse of AD will be computed tomography angiography or transesophageal echocardiography and final diagnosis established after reviewing of all available data.
The accuracy, failure rate and efficiency of a diagnostic strategy combining standardized clinical stratification via the ADD risk score with d-dimer testing will therefore be assessed.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Heart Institute, University of Sao Paolo, São Paulo, Brazil
Acute AD will include the following etiological entities, also known as acute aortic syndromes: acute aortic dissection, intramural aortic hematoma, penetrating aortic ulcer and spontaneous aortic rupture.
A pre-specified secondary sub-analysis will evaluate the diagnostic accuracy of focus cardiac ultrasound (FoCUS) and chest x ray for suspected AD.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: 2 weeks after the end of recruitment
The diagnostic performance of d-dimer will be assessed by computing sensitivity, specificity, negative and positive predictive values and negative and positive likelihood ratios with their 95% confident interval (95% CI) in all patients and within ADD risk score classes. The ADD risk score will be calculated based on the number of categories where at least one risk marker is present. Patients will be divided in low-risk (0 risk markers, ADD risk score 0), intermediate-risk (ADD risk score 1, at least 1 risk marker in 1 ADD risk category) and high-risk (ADD risk >1, at least 1 risk marker in >1 ADD risk categories). For diagnostic accuracy analyses, also a category of non-high-risk patients (ADD risk score ≤1) will be used.
Time frame: 2 weeks after the end of recruitment
Conventional accuracy measures, failure rate and the efficiency of d-dimer will be calculated in high-risk patients (ADD risk score >1), in low-risk patients (ADD risk score 0) and in the intermediate and low-risk patients combined (non high-risk patients, ADD risk score ≤1). Failure rate (false negative proportion) will be calculated as the number of patients with a negative d-dimer and a final diagnosis of AD divided by all patients with negative d-dimer in the same risk group. The efficiency of the diagnostic strategy will be calculated as the number of patients with a negative d-dimer within a risk group divided by all included patients.
Time frame: 2 years after after the end of recruitment
FoCUS will be performed during the Emergency Department index visit, before conclusive diagnosis. FoCUS will assess presence/absence of the following sonographic signs: intimal flap, intramural aortic hematoma, penetrating aortic ulcer, thoracic aorta enlargement, pericardial effusion/tamponade, aortic valve regurgitation. Conventional accuracy measures of FoCUS for aortic dissection will be assessed. Also the failure rate and efficiency of diagnostic strategies integrating FoCUS with ADD risk score and d-dimer test result will be assessed.
Azienda Ospedaliero-Universitaria Careggi
Other
Aortic Dissection Detection Risk Score Plus D-dimer in the Diagnostic Workup of Suspected Acute Aortic Dissection: a Prospective Multicenter Study
Acronym: ADvISED
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05582967
Acute Aortic Syndrome, Aneurysm
Bath, United Kingdom
View Trial DetailsNCT07379294
AORTIC VALVE DISEASES, Acute Aortic Syndrome
View Trial DetailsNCT04014972
Acute Aortic Syndrome, Aneurysm
View Trial DetailsNCT02380716
Acute Aortic Syndrome, Aneurysm
Los Angeles, California, United States
View Trial Details