NCT Number: NCT01598428
* The purpose of this study is to evaluate effects of anterior capsule polishing on effective lens position (ELP) and actual axial movement of the intraocular lens (IOL) by measuring anterior chamber depth (ACD) * patients with bilateral age-related cataract undergo bilateral uneventful cataract surgeries with in-the- bag implantation of a single-piece hydrophobic acrylic foldable IOL (SN60WF). The anterior capsule was extensively polished using Whitman Shepherd Double-Ended Capsule Polisher in one eye randomly, and the other not. The ACD was measured 1day, 1 week, 1month, 3 months and 6 months with anterior segment Optical Coherence Tomograph (AS-OCT) postoperatively. The actual axial movement of IOL was defined as the root mean square (RMS) of the change in ELP at each visit.
Looking for future studies?
Notify MeAll sexes
Interventional
Not applicable
Jinan, Shandong, 250013, China
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
polish the anterior capsule and the equator of capsule extensively with a Whitman Shepherd Double-Ended Capsule Polisher
Time frame: 1 day,1 week, 1 month,3 months and 6 months postoperatively
Effective lens position was measured with anterior chamber depth 1 day,1 week, 1 month as well as 3 months and 6 months postoperatively using anterior segment Optical Coherence Tomograph. The anterior chamber depth defined as the distance between the posterior surface of the corneal and anterior surface of intraocular lens in the pupil center along the optical axis. The actual movement of intraocular lenses was defined as the root mean square of changes in the effective lens position at each visit.
Time frame: 1 day,1 week, 1 month as well as 3 months and 6 months postoperatively
The UCVA was recorded in logMAR units at each vist
Time frame: 1 day,1 week, 1 month as well as 3 months and 6 months postoperatively
auto refraction was performed at each visit. Spherical equivalent refraction (SER) (sphere +cylinder/2) was used in subsequent calculations.
Shandong University
Other
Effect of Anterior Capsule Polishing on Effective Lens Position After Cataract Surgery
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07735000
Age Related Cataract, Cataract
Peshawar, KPK, Pakistan
View Trial DetailsNCT07605260
Cataract, Eye Diseases
Islamabad, Punjab Province, Pakistan
View Trial DetailsNCT06428955
Cataract, Eye Diseases
Indianapolis, Indiana, United States
View Trial DetailsNCT06111222
Cataract, Eye Diseases
Heidelberg, Germany
View Trial Details