Abbott SJM Rigid Saddle Ring
DeviceThe Abbott SJM Rigid Saddle Ring is a rigid, polyester-velour-covered, titanium alloy mitral annuloplasty ring with a saddle shape intended to mimic the shape of a healthy mitral annulus during systole.
NCT Number: NCT04761120
ARB-PMCF is a multicenter, observational study of the safety and performance of Abbott annuloplasty devices used in surgical repair of mitral and tricuspid valve regurgitation. The devices included in this study are the SJM™ Rigid Saddle Ring and SJM Séguin Annuloplasty Ring, indicated for mitral valve repair, and the SJM Tailor™ Annuloplasty Ring and SJM Tailor Annuloplasty Band, indicated for mitral or tricuspid repair. Participants will be enrolled prior to undergoing mitral or tricuspid valve repair surgery including an Abbott annuloplasty implant and will complete annual follow-up visits through five years from implant. The study is being conducted to meet post-market clinical follow-up requirements of the European Union Medical Device Directives.
Interested in participating?
Request Info18 year and older
All sexes
Observational
Tartu University Hospital, Tartu, Estonia
The ARB-PMCF Study has a prospective, multicenter, observational, parallel group design in which up to 550 subjects will be followed through five years from implant of an Abbott annuloplasty device, with or without concomitant procedures, in five treatment groups, including primary mitral disease repair (N=200) with the Rigid Saddle Ring, Séguin Ring or full Tailor Ring without cut zone removal; secondary mitral disease repair (N=200) with the Rigid Saddle Ring, Séguin Ring or full Tailor Ring; primary tricuspid disease repair with the full Tailor Ring (N=50); secondary tricuspid disease repair with the full Tailor Ring (N=50); and primary tricuspid disease repair with the Tailor Band or partial Tailor Ring with cut zone removed (N=50). Study enrollment will occur at up to 25 global centers with approximately half or more of all implanted subjects being from European sites. The study will enroll adult subjects expected to be implanted with an Abbott annuloplasty device within 90 days who meet all other eligibility requirements. Participants will complete annual in-clinic or telephone follow-up visits through five years from their annuloplasty implant. Data collected will include adverse events, cardiac medication usage, New York Heart Association functional classification (a measure of the severity of heart failure symptoms) and echocardiographic assessments of regurgitation through the repaired valve.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The Abbott SJM Rigid Saddle Ring is a rigid, polyester-velour-covered, titanium alloy mitral annuloplasty ring with a saddle shape intended to mimic the shape of a healthy mitral annulus during systole.
The Abbott SJM Séguin Ring is a semi-rigid, polyester-velour-covered, polyethylene mitral annuloplasty ring that varies in thickness and flexibility over its circumference, with the posterior portion of the ring having greater flexibility than the anterior portion.
The Abbott SJM Tailor Ring is a flexible, polyester-velour-covered, silicone annuloplasty ring indicated for use in surgical repair of the mitral or tricuspid valve. The Tailor Ring can be implanted as a full annuloplasty ring, or the surgeon can remove the ring's cut zone with a scalpel and use the partial Tailor Ring as a posterior annuloplasty band.
The Abbott SJM Tailor Band is a flexible, polyester-velour-covered, silicone band for posterior annuloplasty indicated for use in surgical repair of mitral or tricuspid valve. The Tailor Band is identical to the Tailor Ring with the cut zone removed, save that the polyester covering is sewn closed at the ends of the band during manufacturing.
Time frame: 5 years
Percentage of participants in each study treatment group (Groups 1 through 5) who are free of death from any cause through 5 years after their Abbott annuloplasty device implant, estimated from time-to-event data using the Kaplan-Meier estimator. This outcome will be reported for each treatment group separately.
Time frame: 5 years
Percentage of participants in each mitral treatment group (Groups 1 and 2) who are free from reoperation or transcatheter intervention for mitral regurgitation through 5 years after their Abbott annuloplasty implant, estimated from time-to-event data using the Kaplan-Meier estimator. This outcome will be reported separately for Group 1 and Group 2.
Time frame: 1 year
This outcome will be reported for each tricuspid repair group (Groups 3 through 5) separately. NYHA functional classification is a widely used indicator of the severity of heart failure symptoms with four classes:
Class I. No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation, or dyspnea (shortness of breath).
Class II. Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, or dyspnea.
Class III. Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, or dyspnea.
Class IV. Unable to carry on any physical activity without discomfort. Symptoms of heart failure at rest. If any physical activity is undertaken, discomfort increases.
Time frame: Pre-Operative Baseline, within 60 days post-implant, and 1, 3 and 5 years post-implant
This outcome will be reported for each treatment group separately at each timepoint. Regurgitation occurs when a heart valve does not fully seal, allowing backflow of blood through the closed valve. Mitral and tricuspid valve regurgitation in this study will be graded as none/trivial, mild, moderate or severe by echocardiographic assessment. Moderate or severe regurgitation can cause symptoms of heart failure, such as fatigue, shortness of breath and exercise intolerance.
Time frame: Pre-Operative Baseline, within 60 days post-implant, and 1, 3 and 5 years post-implant
This outcome will be reported for each treatment group separately at each timepoint. NYHA functional classification is a widely used indicator of the severity of heart failure symptoms with four classes:
Class I. No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation, or dyspnea (shortness of breath).
Class II. Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, or dyspnea.
Class III. Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, or dyspnea.
Class IV. Unable to carry on any physical activity without discomfort. Symptoms of heart failure at rest. If any physical activity is undertaken, discomfort increases.
Contact information is provided by the study sponsor or research team.
Karine Miquel
CONTACT
Leslie Ornelas
CONTACT
Abbott Medical Devices
Industry
Annuloplasty Rings and Band Post-Market Clinical Follow-Up (ARB-PMCF) Study
Acronym: ARB-PMCF
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06667128
Aortic Regurgitation Disease, Aortic Stenosis
Milan, Italy
View Trial DetailsNCT06675448
Cardiovascular Diseases, Heart Diseases
Falls Church, Virginia, United States
View Trial DetailsNCT07085650
Arrhythmias, Cardiac, Atrial Fibrillation
Shenyang, Liaoning, China
View Trial DetailsNCT06836011
ATTR Amyloidosis Wild Type, ATTR Amyloidosis With Cardiomyopathy
Graz, Styria, Austria
View Trial Details