AngioSculpt® Coronary Bifurcation Study

The purpose of this study is to evaluate a new angioplasty catheter, AngioSculpt® for the treatment of bifurcation lesions (blockages occurring at branch points) in coronary arteries.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Columbia University Medical Center

New York, 10032, United States

About this study

Background: Bifurcation lesions, which consist of a narrowing occurring at branch points of coronary arteries, typically involve both the main branch (parent vessel) and an adjacent side branch. These lesions pose a particularly challenging situation for angioplasty procedures due to the difficulty of covering both branches with stents and a higher rate of recurrence (restenosis). A new angioplasty scoring balloon catheter (AngioSculpt®) has recently been approved for the treatment of narrowings in coronary arteries. The AngioSculpt® catheter incorporates a nitinol device that consists of spiral wires that wrap around the balloon catheter. As the balloon inflates, the spiral wires score the lesion allowing the balloon to be more stable (avoid slippage) and may enlarge the narrowed sections of the artery with less pressure or risk of dissection (uncontrolled tearing of the inner lining of the artery wall commonly seen with conventional balloons).

Study Purpose: To demonstrate the safety and efficacy of the AngioSculpt® used in conjunction with coronary stents (implantable wire mesh tubes for scaffolding blocked arteries) for the treatment of coronary artery bifurcation narrowings and to compare these results with the historical outcomes associated with the use of conventional balloons and stents in the treatment of bifurcation lesions.

Study Design: A prospective, multi-center, non-randomized, single-arm study with results compared to a literature search derived historical control for conventional balloon angioplasty (OPC - Objective Performance Criteria). The intent of this study is to enroll and treat 100 patients at 8 U.S. interventional cardiology programs with clinical follow-up planned at 30 days and 9 months following the procedure.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • At least 18 years of age and able to give informed consent.
  • Patients with significant (> 50% diameter stenosis) native coronary artery disease involving a bifurcation and the ostium of the side branch vessel (Medina class (x, x, 1)) including stable or unstable angina and silent ischemia.
  • Patients with lesions suitable for percutaneous coronary intervention (PCI).

Exclusion criteria

  • Concomitant use of Rotablator, Cutting Balloon, or investigational coronary devices.
  • Additional planned coronary interventions for a non-target lesion within 9 months of the study procedure.
  • Left ventricular ejection fraction < 35%
  • Patients refusing or not candidates for emergency coronary artery bypass grafting (CABG)surgery
  • Uncontrolled severe hypertension (systolic BP >180 mm Hg or diastolic BP >110 mm Hg)
  • Patients who are not candidates for chronic treatment with aspirin or Clopidogrel/Ticlopidine
  • Severe renal failure with creatinine >2.0 mg/dL
  • Untreated pre-procedural hemoglobin <10 g/dL
  • Coagulopathy manifested by platelet count <100,000 or International Normalized ratio (INR) >2.0 (INR is only required in patients who have taken warfarin within 2 weeks of enrollment)
  • Women who are known or suspected to be pregnant
  • Patients in cardiogenic shock
  • Acute myocardial infarction (MI) within the past 72 hours, and/or elevated CPK (and abnormal Troponin-I) at the time of enrollment
  • Patients with a life expectancy of less than 1 year
  • Target main branch vessel < 2.5 mm in diameter
  • Target main branch lesion > 30 mm in length
  • Intended use of a bare metal stent (BMS) in the main branch
  • Target side branch vessel < 2.0 mm in diameter
  • Target side branch lesion > 15 mm in length
  • Target bifurcation angle > 90º (distal angle)
  • Totally obstructed target coronary arteries (TIMI 0 or 1 flow)
  • Target bifurcation lesion within a previously placed stent (i.e. in-stent restenosis (ISR))
  • Target bifurcation lesion within a surgical conduit (e.g. saphenous vein or internal mammary)
  • Target lesion demonstrating severe dissection prior to planned deployment of the AngioSculpt device
  • Unprotected Left Main diameter stenosis ≥ 50%
  • Visible thrombus (by angiography) at target lesion site
  • Coronary spasm in the absence of a significant stenosis
  • Patients who are concurrently participating in an investigational study when such participation could confound the treatment or outcomes of this study

Treatment and study plan

AngioSculpt® Scoring Balloon Catheter

Device

Use of a stent for the main branch of a bifurcation lesion and use of a scoring balloon for the side branch of the same bifurcation lesion

AngioSculpt Scoring Balloon Catheter

Device

Treatment of the side-branch vessel of true bifurcation lesions using the AngioSculpt device

Primary outcomes

  1. Procedural Success

    Time frame: 1 day

    Defined as less than or equal to 30% diameter stenosis in the main branch and less than or equal to 70% diameter stenosis in the side branch at the conclusion of the procedure (including adjunctive stenting) in the absence of in-hospital major adverse cardiac events (MACE) [cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR]

Secondary outcomes

  1. Major Adverse Cardiovascular Events

    Time frame: 30 days

    cardiac death, myocardial infarction, or target lesion revascularization

  2. Major Adverse Cardiac Events

    Time frame: 9 months

    cardiac death, myocardial infarction, or target lesion revascularization

Sponsors and collaborators

Lead sponsor

AngioScore, Inc.

Industry

Registry information

Official study title

AngioSculpt® Scoring Balloon Catheter Multi-Center Coronary Bifurcation Study

Acronym: AGILITY

Important dates

Study start
2008
Primary completion
2010
Study completion
2011
First posted
May 30, 2008
Registry last updated
Aug 10, 2011

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.