Anal Resting Pressure After Bidet, Compared to Sitz Bath

Sitz bath is conventional and empirical remedy and commonly recommended for non-operative treatment of various anal diseases. However, as there was no substitute for sitz bath until now, the patients have to accept the inconvenience for treatment of their diseases.

Electronic bidet is used with convenience as automatic device for cleansing the perineal area, especially after defecation. The similarity of contacting water to perineal area, clinical use of electronic bidet has been suggested for treatment of anal diseases. However, there had been few reports of clinical use of electronic bidet.

Investigators performed the study to evaluate the effects of electronic bidet on anal resting pressure, compared to conventional warm sitz bath in normal healthy volunteers.

Completed

Looking for future studies?

Notify Me

Key information

Age range

20 year–40 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Early Phase 1

Primary location

Seoul National University Hospital

Seoul, Jongro-gu, 110-744, South Korea

About this study

Baseline Anorectal Manometry

The Subjects underwent a digital rectal examination and baseline anorectal manometry in the lateral decubitus position using a device from Dynacompact (Menfis Biomedica Corp., Bologna, Italy) using an 8 channel polyvinyl (PVC) catheter with the measuring orifices oriented radially. Resting and maximal pressure in the anal canal were measured by pulling the catheter out of the anorectum at a speed of 0.5 mm/sec (the 'rapid pull through' technique)

Recordings of Anal Resting Pressure on Electronic Bidet and Sitz Bath

The subjects underwent clinical experiments for recordings of anal resting pressure changes using the electronic bidet and taking the sitz bath. For the measurement of effects of electronic bidet on anal resting pressure, a different manometry catheter (8 spirally arranged channels, 0.5 cm apart) was inserted into the anal canal placing the upper channels (channels No. 1-2) with a temperature probe in the rectum and the lower channels (channel No. 3-8) in the anal canal. The catheter was fixed in the buttock area using waterproof tape and subjects sat on a toilet equipped with an electronic bidet (Coway Corp, Seoul, Korea). After anal resting pressure had stabilized at the sitting position, anal resting pressure at high pressure zone (HPZ) was checked as control value to measure the change of anal resting pressure. The anal high pressure zone (HPZ) was defined as the channel representing the highest pressure within the anal canal for each subject. The pressures while sitting were adjusted for gravity. A water flow of the electronic bidet was applied to the anus for 3 minute. We designed the new water flow system of the electronic bidet, which was fountain type with very low force (10mN), as water falls down immediately after contacting the perineal area (Fig 1A). Before applying the water flow, mist type of water particles was sprayed for a few seconds for gentle contact with water first. The water used in the electronic bidet was a tap water of warm temperature about 38 degree celsius. Anal resting pressure at the channel of HPZ was checked at 1, 2 and 3 minutes after using the electronic bidet and percentage of anal resting pressure was calculated with compared to control value checked before using the electronic bidet. Maximum and minimum pressures in the HPZ during application of the electronic bidet were noted.

Sitz bath was also undergone at another day. After insertion of catheter, the subjects were seated on a chair with small tub filled with warm water of about 38 degree celsius and sink their buttock (Fig 1B). The measurements of anal resting pressure were similar to the electronic bidet. Anal resting pressures of HPZ were checked before and after using the electronic bidet for 3 minutes. Maximum and minimum pressures were also checked.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • health volunteers

Exclusion criteria

  • anorectal disorder
  • medical comorbidities
  • pregnancy
  • history of vaginal delivery

Treatment and study plan

Electronic bidet

Device

commercial electronic bidet

Sitz Bath

Device

Conventional sitz bath

Primary outcomes

  1. Anal Resting Pressure Change

    Time frame: 3 minute

    before and after bidet/sitz bath for 3 minute

Secondary outcomes

  1. Convenience

    Time frame: 3 minute

    Questionnaires

Sponsors and collaborators

Lead sponsor

Seoul National University Hospital

Other

Collaborators

  • Coway Research and Development Center

Registry information

Official study title

The Effects of Electronic Bidet on Anal Resting Pressure, Compared to Conventional Sitz Bath in Normal Healthy Volunteers

Acronym: Bidet(2)

Important dates

Study start
2011
Primary completion
2014
Study completion
2014
First posted
Sep 19, 2014
Registry last updated
Oct 3, 2014

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.