Skip to main content
OpenTrials
Completed

NCT Number: NCT03622645

An Objective Measurement Method With The Leap Motion Sensor For Hand And Wrist's Range Of Motion

The aim of the study was to develop a low cost, clinically easy to use measurement method with the Leap motion sensor for objectively evaluating range of motion (ROM), and to investigate the validity and reliability of this application.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

18 year–40 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

About this study

. Wrist flexion / extension, radial / ulnar deviation, supination / pronation, 1.-5. of the fingers DIP, PIP and MCP flexion / extension ROM measurements will be made with universal goniometer and developed Leap motion sensor (LMC) based measurement method.

The study consists of two basic steps:

  • Development of measurement method with LMC Identification of normROM measurement procedure Identification of ROM measurement reporting Establishing the precursor version of the software of the measurement method Checking ROM measurement performance criteria and providing feedback Measuring the movement defined on 5 persons and providing feedback Creation of the last available version of the measurement method
  • Validity and reliability study Measurements of hand and wrist ROM with developed measurement method with LMC and universal goniometer for three times and calculation mean of three measurement for two methods

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Healthy individuals

Exclusion criteria

  • Have any hand/wrist problems between the ages of 18-40 years.

Treatment and study plan

Assessment of Range of Motion with Leap Motion sensor

Device

An ROM measurement method called as HandROM by us will be developed with leap motion sensor

Primary outcomes

  1. Range of Motion

    Time frame: Baseline

    Wrist flexion / extension, radial / ulnar deviation, supination / pronation, 1. -5. DIP, PIP and MCP flexion / extension EHA measurements of the fingers will be made with universal goniometer and developed Leap motion sensor based measurement method.

Sponsors and collaborators

Lead sponsor

Istanbul University

Other

Registry information

Official study title

Developing An Objective Measurement Method With The Leap Motion Sensor For Hand And Wrist's Range Of Motion: Validity And Reliability Study

Important dates

Study start
2017
Primary completion
2018
Study completion
2018
First posted
Aug 9, 2018
Registry last updated
Nov 6, 2018

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.