Videncenter for Saarheling
Copenhagen NV, 2400, Denmark
NCT Number: NCT02351791
The primary purpose of the study is to investigate the impact that feces mixtures have on the peristomal skin when using a standard adhesive.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Copenhagen NV, 2400, Denmark
Six types of patches are tested:
Patch 1: Standard adhesive with own feces
Patch 2: Standard adhesive with own feces mixture
Patch 3: Standard adhesive with simulated feces
Patch 4: Standard adhesive with simulated feces mixture
Patch 5: Standard adhesive with buffer (control)
Patch 6: Standard adhesive with buffer feces mixture (control)
Each subject is randomized to one of two arms testing three patches on the peristomal skin (patch 1, 3 and 5 or patch 2, 4 and 6). Furthermore, within each arm an attempt will be made to randomize each of the three patches on the peristomal skin to one of three locations surrounding the stoma (upper left, upper right, lower). On the healthy contralateral abdominal skin the subjects test all six patches.
A run in period with 2 subjects (healthy volunteers) was conducted to clarify the length of the test period. They were exposed to 4 patches (patch 3-6) on healthy abdominal skin which was removed at 2 different time slots. Based on the results the test period was established
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patch 1:standard adhesive with own feces in sleeve
Patch 2:standard adhesive with own feces mixture in sleeve
Patch 3: standard adhesive with simulated feces in sleeve
Patch 4:standard adhesive with simulated feces mixture in sleeve
Patch 5:standard adhesive with buffer in sleeve
Patch 6:standard adhesive with buffer mixture in sleeve
Time frame: Approximately 7-10 hours
Trans Epidermal Water Loss is a standardized non-invasive method for describing the barrier function of the skin. Damage to the skin surface (stratum corneum) will lower the barrier of the skin and thereby increase water loss. This can be used as a measure for the damaging effect of the adhesives to the skin. Trans Epidermal Water Loss is measured by applying a probe to the skin surface and is assessed nine times for each patch after applying the patch: three repeated measurements of the skin covered by the center of the patch (Center), as well as three repeated measurements of the skin covered by the adhesive (Under adhesive).
Coloplast A/S
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07684755
Ileostomy
Karachi, Sindh, Pakistan
View Trial DetailsNCT07601594
Colorectal Surgery, Ileostomy
Lahore, Punjab Province, Pakistan
View Trial DetailsNCT06614491
Colostomy, Ileostomy
São Paulo, Brazil
View Trial DetailsNCT02626260
Ileostomy
Humlebæk, Denmark
View Trial Details