Skip to main content
OpenTrials
Recruiting

NCT Number: NCT04029337

An Early Feasibility Study of the HighLife 28mm Trans-Septal Transcatheter Mitral Valve Replacement System

Study to evaluate the feasibility, safety and performance of the HighLife trans-septal Transcatheter Mitral Valve in patients with moderate-severe and severe mitral regurgitation who are at high risk for surgical treatment.

Recruiting

Interested in participating?

Request Info

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Tucson Medical Center, Tucson, Arizona, United States

Loading trial locations.

About this study

Protocol Title:

An Early Feasibility Study of the HighLife 28mm Transcatheter Trans-Septal Mitral Valve Replacement System

Protocol # HL-2019-01, ver. 5.0

Phase: United States Early Feasibility Study

Investigational Devices:

The HighLife 28mm Trans-Septal Mitral Valve and its delivery systems. These devices compose the HighLife Trans-septal Mitral Valve Replacement (TSMVR) System.

  • Size 28 mm TMV (CLARITY valve)
  • Size 28 mm TMV-L (CLARITY large annulus valve/ LAV)

Intended Use: The HighLife TSMVR system is intended for the trans-septal access percutaneous mitral valve replacement in patients suffering from symptomatic moderate-severe or severe mitral regurgitation (MR) due to primary (degenerative) or secondary (functional) abnormality of the mitral valve.

Device Description:

The HighLife TSMVR system is composed of a Trans-Septal (Mitral Valve (TSMV), a sub-annular implant (SAI), and their delivery systems and accessories. The TMV is a 28 mm mitral bioprosthesis made of a self-expanding Nitinol frame covered with polyester graft and supporting bovine pericardium leaflets. The bioprosthesis is used in conjunction with the Sub-Annular Implant (SAI), comprising a ring (made of polycarbonate urethane (PCU), nitinol, gold markers and polyester (Dacron) to be placed around the mitral valve apparatus to stabilize the position of the mitral valve implant.

Design: A single arm, prospective, multicenter, non-randomized and open-labelled study.

Purpose: The purpose of the study is to evaluate the feasibility, safety and performance of the HighLife 28mm Trans-septal Mitral Valve Replacement (TSMVR) system in NYHA Class ≥ II-IV patients with moderate-severe or severe mitral regurgitation who are at high risk for surgical treatment or deemed more appropriate to receive transcatheter mitral valve replacement than to receive conventional mitral valve surgery according to the local multidisciplinary Heart Team.

Objectives: Primary objectives are to evaluate the feasibility, safety and performance of the HighLife 28mm TSMVR system at 30 days. Secondary objectives are to evaluate long term safety and performance of the HighLife TSMVR system.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age ≥ 18 years
  • Severe mitral regurgitation
  • New York Heart Association (NYHA) Functional Class II, III or ambulatory IV.
  • Patient is under maximally tolerated GDMT (incl. CRT) for at least 3 months
  • Multidisciplinary Heart Team consensus that the patient is inoperable or at high-risk for surgical repair/replacement due to significant co-morbid conditions
  • Multidisciplinary Heart Team consensus that the patient is not a suitable candidate for other approved percutaneous repair therapy due to anatomical or medical conditions
  • Patient meets the anatomical criteria for HighLife valve sizing as determined by CT and TEE

Main Exclusion Criteria:

  • Mitral stenosis
  • Rheumatic valve disease
  • Severe calcifications of the mitral annulus and/or mitral leaflets
  • Prior surgical or interventional treatment of the mitral valve
  • Unsuitable anatomy for the transapical access
  • Unsuitable anatomy of the aorta and ilio-femoral vessels for the transfemoral access
  • Untreated clinically significant coronary artery disease requiring revascularization
  • LVEF < 30%
  • LVEDD > 70mm
  • Echocardiographic evidence of intracardiac mass, thrombus or vegetation
  • Hypertrophic Obstructive Cardiomyopathy (HOCM)
  • Any surgical or interventional procedure (including PCI) done in the past 30 days prior to procedure

Treatment and study plan

Transcatheter Mitral Valve Replacement

Device

Minimally invasive transcatheter mitral valve implantation using the HighLife™ TMVR system

Primary outcomes

  1. Freedom of major adverse events

    Time frame: at 30 days post procedure

    including:

    • All-cause mortality
    • Myocardial infarction or coronary ischemia requiring PCI or CABG
    • Major stroke
    • Life-threatening bleeding (MVARC scale)
    • Major access and vascular complications
    • Stage 2 or 3 acute kidney injury (includes dialysis)
    • Any valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention
    • Severe hypotension, heart failure or respiratory failure requiring intravenous pressors or invasive or mechanical heart failure treatments such as ultrafiltration or hemodynamic assist devices, including intra-aortic balloon pumps or left ventricular or biventricular assist devices, or prolonged intubation for ≥ 48H
  2. Continued intended performance of the HighLife™ bioprosthesis

    Time frame: at 30 days post procedure

    defined as the reduction of mitral regurgitation (MR) to either optimal (0+ to trace) or acceptable (reduced by at least 1 grade from baseline with no more than 2+ MR) without significant mitral stenosis (post-procedure EOA ≥ 1.5 cm2 with a transmitral gradient < 5mmHg) and with no greater than mild (1+) paravalvular MR (and without associated hemolysis)

Secondary outcomes

  1. Technical success

    Time frame: immediately after procedure

    defined as alive patient at exit from procedure room, with all of the following:

    • Successful access, delivery and retrieval of the HighLife delivery systems
    • Deployment and correct positioning of the HighLife bioprosthesis
    • Freedom of additional emergency surgery or re-intervention related to the device or access procedure

Sponsors and collaborators

Lead sponsor

HighLife SAS

Industry

Registry information

Important dates

Study start
2020
Primary completion
2025
Study completion
2030
First posted
Jul 23, 2019
Registry last updated
Mar 17, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.