Skip to main content
OpenTrials
Recruiting

NCT Number: NCT06909682

AI-Based Monitoring System for Chronic Heart Failure With Advanced Wearable and Mini-Invasive Devices

The goal of this observational, multicenter study is to evaluate whether AI-driven remote monitoring using a mini-invasive wearable device can improve clinical outcomes in adult patients (≥18 years) with chronic heart failure (CHF).

The main questions it aims to answer are:

* Can continuous remote monitoring reduce hospital admissions (emergency visits and hospitalizations) by 20% compared to standard care? * Does wearable-based remote monitoring improve functional, biochemical, and instrumental parameters in CHF patients? Researchers will compare patients using the wearable device (intervention group) to those receiving standard clinical follow-up (control group) to assess whether AI-driven monitoring leads to fewer hospitalizations, better disease management, and improved quality of life.

Participants will:

* Wear the EmbracePlus (Empatica Inc.) device continuously for six months (intervention group only). * Have their biometric data (SpO₂, HRV, EDA, respiratory rate, temperature, sleep quality) monitored remotely. * Receive automated alerts and teleconsultations if abnormal physiological changes are detected. * Attend scheduled follow-up visits (remote and in-person) for clinical evaluation and treatment adjustments.

The study aims to provide real-world evidence on whether integrating wearable health technology with AI analytics can enhance CHF management and improve patient outcomes.

Recruiting

Interested in participating?

Request Info

Key information

Age range

19 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Hospital University San Giovanni di Dio and Ruggi d'Aragona

Salerno, Italy

Location status: Recruiting

Location contact

Alessia Bramanti, Associate Professor

CONTACT

About this study

Chronic Heart Failure (CHF) is a multifactorial syndrome characterized by high rates of hospitalization, morbidity, and mortality. Despite advances in pharmacological and device-based therapies, early identification of clinical deterioration remains a major challenge. Traditional follow-up models, based primarily on intermittent in-person evaluations, are often inadequate in capturing subclinical changes that precede acute decompensation.

The SMART-CARE (System of Monitoring and Analysis based on Artificial Intelligence for Chronic Heart Failure Patients with Mini-Invasive and Wearable Medical Devices) study aims to assess whether continuous remote monitoring using a CE (Conformité Européenne)-certified wearable device (EmbracePlus by Empatica Inc.) integrated with AI (Artificial Intelligence) analytics can improve the management of CHF patients. The study adopts a prospective, multicenter, observational design with two parallel cohorts: patients managed with standard care versus patients equipped with the wearable device for six months.

The wearable device captures a range of physiological signals-including peripheral capillary oxygen saturation (SpO₂), heart rate variability (HRV), electrodermal activity (EDA), skin conductance level (SCL), respiratory rate, peripheral skin temperature, pulse rate, fatigue detection, and sleep metrics via actigraphy-and transmits them in real time to a centralized digital platform. AI algorithms analyze these data continuously, triggering alerts in the event of abnormal trends. When alerts are generated, patients undergo teleconsultation, with possible treatment adjustments or in-person follow-up as clinically indicated.

The study is designed to generate real-world evidence on whether AI-enhanced monitoring can reduce unplanned hospital admissions by at least 20% over a six-month follow-up, compared to standard care. Secondary endpoints include improvements in cardiac function (evaluated through echocardiographic parameters), neurohormonal biomarkers such as B-type Natriuretic Peptide (BNP) and Atrial Natriuretic Peptide (ANP), exercise tolerance assessed by the Six-Minute Walk Test (6MWT), quality of life measured by the Kansas City Cardiomyopathy Questionnaire (KCCQ), and incidence of therapy-related adverse events (e.g., hypotension, bradyarrhythmias).

In addition to evaluating clinical efficacy, the study supports the development of a predictive multimarker model. Data collected through the SMART-CARE platform-including clinical history, biochemical markers, imaging data, and continuous sensor-derived variables-will be used by collaborating academic centers to train AI algorithms capable of forecasting CHF progression and tailoring individualized interventions.

All data are pseudonymized in compliance with the General Data Protection Regulation (GDPR, Regulation EU 2016/679). The study does not interfere with ongoing medical treatments and adheres to Good Clinical Practice (GCP) and the ethical principles of the Declaration of Helsinki. Patients provide written informed consent prior to enrollment.

The SMART-CARE initiative reflects a broader goal: integrating telemedicine, wearable health technology, and AI-based predictive modeling into a seamless care pathway that promotes proactive CHF management and enables personalized, data-driven therapeutic decisions.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age ≥ 18 years (adults of any sex)
  • Confirmed diagnosis of chronic heart failure (CHF) for at least 6 months prior to screening
  • Stable on optimized heart failure therapy for at least one month before enrollment
  • Any left ventricular ejection fraction (LVEF) classification, including:
  • Heart Failure with Reduced Ejection Fraction (HFrEF)
  • Heart Failure with Mid-Range Ejection Fraction (HFmrEF)
  • Heart Failure with Preserved Ejection Fraction (HFpEF)
  • NYHA Functional Class I, II, or III
  • History of at least one hospital admission or outpatient visit in the past 12 months requiring intravenous (IV) diuretics, vasodilators, or inotropes for CHF exacerbation
  • Ability to provide written informed consent or availability of a legally authorized representative Exclusion Criteria
  • NYHA Functional Class IV or anticipated heart transplant or ventricular assist device (VAD) implantation within 6 months of screening
  • Severe renal impairment (eGFR < 30 mL/min/1.73 m²) or dialysis dependence
  • Terminal comorbidities (e.g., advanced cancer, end-stage pulmonary disease) significantly limiting life expectancy
  • Pregnancy
  • Presence of skin conditions or allergies preventing prolonged use of a wearable device
  • Inability to comply with study procedures (e.g., cognitive impairment, significant psychiatric disorders)

Treatment and study plan

Intervention Group (Device Group - AI-Based Remote Monitoring)

Device

This intervention utilizes a mini-invasive wearable device for continuous remote monitoring of chronic heart failure (CHF) patients. Unlike traditional telemonitoring, it integrates AI-driven predictive analytics to track oxygen saturation (SpO₂), heart rate variability (HRV), electrodermal activity (EDA), temperature, respiratory rate, and sleep quality in real time. The system generates automated alerts for healthcare providers, enabling early detection of CHF exacerbation and proactive intervention through teleconsultations, medication adjustments, or in-person evaluations. Data is securely transmitted to a cloud-based platform, allowing continuous risk assessment and personalized care adjustments. This approach aims to reduce unnecessary hospitalizations, enhance patient monitoring, and optimize heart failure management through advanced AI-based digital health technology.

Standard Clinical Follow-Up

Other

Participants in this group will receive standard chronic heart failure (CHF) management according to current clinical guidelines. Their follow-up will consist of scheduled in-person visits every three months, during which they will undergo routine laboratory tests (including BNP, NT-proBNP, renal function, and electrolytes), as well as echocardiography and ECG evaluations. Treatment adjustments will be made based on clinical assessments and reported symptoms. Unlike the intervention group, these participants will not use a wearable device, and their condition will be monitored exclusively through traditional hospital visits and self-reported health status.

Primary outcomes

  1. Change in Hospital Admissions with AI-Based Remote Monitoring

    Time frame: 6 months from participant enrollment.

    The study aims to determine whether AI-based remote monitoring using a wearable device leads to a 20% reduction in hospital admissions (including emergency department visits and hospitalizations) compared to standard clinical follow-up in patients with chronic heart failure (CHF). The intervention group will use a mini-invasive wearable device for continuous physiological monitoring, while the control group will receive standard CHF management without remote monitoring. Hospital admission rates will be analyzed to assess the effectiveness of early AI-driven detection and intervention.

Secondary outcomes

  1. Change in Quality of Life

    Time frame: Baseline, 3 months, and 6 months

    Quality of life (QoL) will be measured using the Kansas City Cardiomyopathy Questionnaire (KCCQ) Overall Summary Score, a validated instrument specifically designed to assess symptom burden, functional status, social limitations, and quality of life in patients with chronic heart failure (CHF). The score ranges from 0 to 100, where higher scores indicate better health status and quality of life. The study will evaluate whether patients in the AI-based remote monitoring group report higher KCCQ scores compared to the control group.

    Unit of Measure: KCCQ score (0-100 scale) Time Frame: Baseline, 3 months, and 6 months Interpretation: Higher scores indicate better outcomes.

  2. Adverse Effects of CHF Therapy

    Time frame: 6 months

    The study will analyze whether continuous AI-driven monitoring helps in reducing adverse effects related to CHF treatments, such as:

    Hypotension (low blood pressure episodes due to overuse of diuretics or vasodilators) Bradyarrhythmias (slow heart rate linked to beta-blockers or other heart failure medications) By detecting early physiological changes, the wearable device may enable timely adjustments in medication dosages, reducing complications and therapy-related hospitalizations.

  3. Change in Biochemical Parameters

    Time frame: 3 and 6 months from participant enrollment

    Biochemical Parameters:

    Change in B-type Natriuretic Peptide (BNP) Levels (picograms per milliliter)

  4. Change in Biochemical Parameters

    Time frame: 3 and 6 months from participant enrollment

    Biochemical Parameters:

    Change in N-terminal pro-BNP (NT-proBNP) Levels (picograms per milliliter)

  5. Change in Biochemical Parameters

    Time frame: 3 and 6 months from participant enrollment

    Biochemical Parameters:

    Change in Serum Creatinine (milligrams per deciliter)

  6. Change in Biochemical Parameters

    Time frame: 3 and 6 months from participant enrollment

    Biochemical Parameters:

    Change in Estimated Glomerular Filtration Rate (eGFR) (milliliters per minute per 1.73 square meters)

  7. Change in Biochemical Parameters

    Time frame: 3 and 6 months from participant enrollment

    Biochemical Parameters:

    Change in Serum Sodium Levels (millimoles per liter)

  8. Change in Biochemical Parameters

    Time frame: 3 and 6 months from participant enrollment

    Biochemical Parameters:

    Change in Serum Potassium Levels (millimoles per liter)

  9. Change in Biochemical Parameters

    Time frame: 3 and 6 months from participant enrollment

    Biochemical Parameters:

    Change in Serum Chloride Levels (millimoles per liter)

  10. Change in Functional ECG-Derived Parameters

    Time frame: 3 and 6 months from participant enrollment

    ECG-Derived Parameters:

    Change in Heart Rate Variability (HRV) (milliseconds)

  11. Change in Functional ECG-Derived Parameters

    Time frame: 3 and 6 months from participant enrollment

    ECG-Derived Parameters:

    Change in Respiratory Rate (breaths per minute)

  12. Change in Functional Echocardiographic derived Parameters

    Time frame: 3 and 6 months from participant enrollment

    Echocardiographic Parameters:

    Change in Left Ventricular Ejection Fraction (LVEF) (percent)

  13. Change in Functional Echocardiographic derived Parameters

    Time frame: 3 and 6 months from participant enrollment

    Echocardiographic Parameters:

    Change in Diastolic Function - E/A Ratio (unitless)

  14. Change in Functional Echocardiographic derived Parameters

    Time frame: 3 and 6 months from participant enrollment

    Echocardiographic Parameters:

    Change in Left Ventricular End-Diastolic Volume (milliliters)

  15. Change in Functional Echocardiographic derived Parameters

    Time frame: 3 and 6 months from participant enrollment

    Echocardiographic Parameters:

    Change in Left Ventricular End-Systolic Volume (milliliters)

Study contacts

Contact information is provided by the study sponsor or research team.

Alessia Bramanti, Electronic Engineering

CONTACT

[email protected]

+393483809181

Sponsors and collaborators

Lead sponsor

University of Salerno

Other

Registry information

Official study title

Smart Monitoring and Analysis System Based on Artificial Intelligence for Patients With Chronic Heart Failure Using Advanced Mini-Invasive and Wearable Medical Devices

Acronym: SMART-CARE

Important dates

Study start
2025
Primary completion
2026
Study completion
2027
First posted
Apr 3, 2025
Registry last updated
Mar 11, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.