AI-Assisted Endoscopy for Upper Aerodigestive Tract Lesions

This is a prospective observational clinical study designed to evaluate the performance of artificial intelligence (AI) algorithms applied to upper aerodigestive tract (UADT) video-endoscopy. The study assesses three main tasks: lesion detection (localization), classification (benign vs malignant), and segmentation of tumor margins.

AI algorithms will be applied to endoscopic video data acquired during routine clinical practice without influencing clinical decision-making. The system will process images in real time and store data for subsequent analysis. AI outputs will be compared with physician assessment and reference standard histopathology to evaluate diagnostic performance.

Not Yet Recruiting

Trial opening soon.

Get Notified

Key information

About this study

The artificial intelligence algorithms developed will be employed in the analysis of laryngeal lesions for 3 tasks:

  • Task 1: Computer aided diagnosis (CADx): the algorithm provides a differential diagnosis between benign and malignant neoplasms (binary classification) and the exact histology (multiclass classification). During the UADT video-endoscopy in the outpatient clinic, the physician performs the video-endoscopy and selects and captures n.3 WL and n.3 NBI significant frames of the lesion. The AI model records the classification output of the algorithm that the physician cannot access. The predicted pathologic results will be finally displayed as two different classifications along with the probability of each prediction (0% to 100%) as estimated by the AI algorithm: a first binary classification "neoplastic" or "non-neoplastic," and a second multiclass classification with the exact histology. The physician subsequently, based on the endoscopic examination, will write the suspected diagnosis (benign vs. malignant lesion and the actual histology) in the appropriate patient chart. Next, the physician reviews the screenshot taken and makes sure the lesion is visible in every one of them. Retrospectively, an investigator (blinded to the physician's assessment) will review the AI processed frames with the resulting CADx classifications and mark the AI-processed diagnosis in the patient chart. Once biopsied, the final histology of the lesion analyzed by definitive histopathological examination is recorded in the patient chart by the investigator. The investigators will finally compare the two recorded diagnoses (CADx and physician) with the definitive histology.
  • Task 2: Computer aided detection (CADe): the algorithm, through the representation of a rectangle (bounding box), localizes the lesion during the video-endoscopy in the outpatient clinic in real-time. During the UADT video-endoscopy, the physician performs the video-endoscopy as for standard-of-care procedure. In parallel, the AI model processes in real-time the endoscopic video and records the output of the algorithm (which the physician cannot access). The physician captures n.3 WL and n.3 NBI significant frames of the lesion. Moreover, n.3 frames where no lesions are visible are captured as negative controls. Later, the physician reviews the screenshot taken and makes sure to label the frames where the lesion is visible as "positive cases" and the frame where the lesion is not visible as "negative cases". The investigators will finally assess if the lesion was detected by the CADe system to define a "true positive". Similarly, to define a true negative, the CADe system should have not output a bounding box in the majority of the "negative cases" frames.
  • Task 3: Computer aided segmentation (CASe): the algorithm analyzes the neoplasm margins and provides a delineation mask. In the operating room setting, once the lesion to be resected is identified with a 0° telescope, the surgeon captures n.1 WL and n.1 NBI close-up photographs that exemplify the superficial lesion margins. The same procedure is repeated with a 70° optics and other two photographs are acquired. The frames taken are then saved and analyzed by the AI algorithm, which will perform the segmentation task. The surgeon will be blinded to the AI prediction. Later, the surgeon will draw the margins of the lesion according to her/his evaluation of each captured frame. The annotated frame will be saved so that it can be analyzed at a later time. Afterwards, in cases where positive superficial margins are identified by histopathologic examination, the surgeon-designed margins and the AI model ones will be compared to see if there was any difference in the suggested margin.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Age > 18 years
  • Injury originating from the upper aero-digestive tract
  • Recording of the video-endoscopic examination
  • Patient known to undergo a biopsy of the lesion or clinical follow-up for lesion with known biopsy (e.g. laryngeal papillomatosis) or suffering from Reinke's edema (in this pathology, in fact, biopsy is not necessary since the diagnosis is clinical)
  • Or patients undergoing transoral lesion excision

Exclusion criteria

  • Submucosal lesion
  • Patients with previous operations on the upper aero-digestive tract
  • Patients with previous radiotherapy of the head and neck district
  • Poor compliance on endoscopic examination
  • Unavailability of CADe/CADx or CASe data logging note

Treatment and study plan

Primary outcomes

  1. Negative Predictive Value of the CADx Algorithm for Malignant or Premalignant Upper Aerodigestive Tract Lesions

    Time frame: From index outpatient UADT video-endoscopy until definitive histopathology result is available, assessed up to 60 days after endoscopy.

    Negative Predictive Value (NPV) of the computer-aided diagnosis (CADx) algorithm for classifying UADT lesions as malignant/premalignant versus benign/non-neoplastic, using definitive histopathology as the reference standard. The CADx final classification will be based on the majority rule across selected white-light and narrow-band imaging frames. NPV = true negatives / (true negatives + false negatives). The pre-specified performance target is NPV ≥ 90%.

  2. Sensitivity of the CADe Algorithm for Localization of Upper Aerodigestive Tract Lesions

    Time frame: At index outpatient UADT video-endoscopy, with blinded post-processing assessment performed up to 30 days after endoscopy.

    Sensitivity of the computer-aided detection (CADe) algorithm for localizing UADT lesions with a bounding box. A true positive is defined as localization of the lesion area by a bounding box in the majority of physician-labeled lesion-positive captured frames. Sensitivity = true positives / (true positives + false negatives).

  3. Median Intersection Over Union Between CASe Segmentation and Surgeon-Drawn Lesion Margins

    Time frame: At intraoperative pre-resection endoscopy, with assessment performed after image annotation up to 30 days after surgery.

    Median overlap between the AI-generated segmentation mask and the lesion margin area drawn by the surgeon on intraoperative endoscopic images. Intersection over Union (IoU) = area of overlap / area of union. Values range from 0 to 1; higher values indicate greater agreement.

  4. Median Dice Similarity Coefficient Between CASe Segmentation and Surgeon-Drawn Lesion Margins

    Time frame: At intraoperative pre-resection endoscopy, with assessment performed after image annotation up to 30 days after surgery.

    Median Dice Similarity Coefficient (DSC) between the AI-generated segmentation mask and the lesion margin area drawn by the surgeon on intraoperative endoscopic images. Dice Similarity Coefficient = 2 × area of overlap / (AI segmented area + surgeon-drawn area). Values range from 0 to 1; higher values indicate greater agreement.

Secondary outcomes

  1. WL-NPV vs. NBI-NPV of CADx classification

    Time frame: From index outpatient UADT video-endoscopy until definitive histopathology result is available, assessed up to 60 days after endoscopy.

    Negative Predictive Value (NPV) of CADx classification calculated using only the three selected white-light frames, compared with definitive histopathology, vs. NPV of CADx classification calculated using only the three selected narrow-band imaging frames, compared with definitive histopathology.

    The final AI-result will be calculated based on the majority rule of the 3 WL and 3 NBI frames computed separately.

  2. Clinician-Reported Usability Score for the AI Endoscopy System

    Time frame: Assessed after clinician use of the AI system during study procedures, up to 20 months after study initiation.

    Usability of the AI endoscopy system assessed using standardized usability questionnaires administered to clinicians after use of the AI system. Questionnaire scoring will be interpreted according to the selected questionnaire manual, with higher scores indicating greater usability.

  3. Sensitivity, Specificity and Accuracy of CADx histology prediction

    Time frame: From index outpatient UADT video-endoscopy until definitive histopathology result is available, assessed up to 60 days after endoscopy.

    Sensitivity, Specificity and Accuracy of the CADx algorithm for histology prediction, compared with definitive histopathology.

  4. F1 Score of CADx Classification

    Time frame: From index outpatient UADT video-endoscopy until definitive histopathology result is available, assessed up to 60 days after endoscopy.

    F1 score of the CADx classification output compared with definitive histopathology.

  5. Area Under the Receiver Operating Characteristic Curve of CADx Classification

    Time frame: From index outpatient UADT video-endoscopy until definitive histopathology result is available, assessed up to 60 days after endoscopy.

    AUC of the ROC curve for CADx classification of UADT lesions compared with definitive histopathology.

  6. Sensitivity, Specificity and Accuracy of human physician histology prediction

    Time frame: From index outpatient UADT video-endoscopy until definitive histopathology result is available, assessed up to 60 days after endoscopy.

    Sensitivity, Specificity an Accuracy of the treating physician's suspected diagnosis compared with definitive histopathology.

  7. Specificity of the CADe Algorithm for Localization of Upper Aerodigestive Tract Lesions

    Time frame: At index outpatient UADT video-endoscopy, with blinded post-processing assessment performed up to 30 days after endoscopy.

    Proportion of physician-labeled lesion-negative frames/cases in which the CADe algorithm does not output a bounding box in the majority of negative-control frames.

  8. Accuracy of the CADe Algorithm for Localization of Upper Aerodigestive Tract Lesions

    Time frame: At index outpatient UADT video-endoscopy, with blinded post-processing assessment performed up to 30 days after endoscopy.

    Overall proportion of correctly classified lesion-positive and lesion-negative cases/frames by the CADe algorithm.

  9. Positive Predictive Value of the CADe Algorithm for Localization of Upper Aerodigestive Tract Lesions

    Time frame: At index outpatient UADT video-endoscopy, with blinded post-processing assessment performed up to 30 days after endoscopy.

    Positive predictive value of CADe bounding-box output for lesion localization. PPV = true positives / (true positives + false positives).

  10. Negative Predictive Value of the CADe Algorithm for Localization of Upper Aerodigestive Tract Lesions

    Time frame: At index outpatient UADT video-endoscopy, with blinded post-processing assessment performed up to 30 days after endoscopy.

    Negative predictive value of CADe absence of bounding-box output for lesion localization. NPV = true negatives / (true negatives + false negatives).

  11. Percentage of Positive Superficial Margin Cases in Which the AI-Predicted Tumor Area Is Wider Than the Surgeon-Drawn Area

    Time frame: At intraoperative pre-resection endoscopy, with assessment performed after image annotation up to 30 days after surgery.

    Among cases with positive superficial margins on final histopathology, percentage of cases in which the AI-predicted tumor area extends beyond the surgeon-drawn margin at the affected margin.

Study contacts

Contact information is provided by the study sponsor or research team.

Leonardo De Mattos, PhD

CONTACT

[email protected]

+39 010 2898 270

Sponsors and collaborators

Lead sponsor

Istituto Italiano di Tecnologia

Other

Collaborators

  • CRO "Centro Clinical Trials" IRCCS Ospedale Policlinico San Martino
  • Hospital Clinic of Barcelona
  • Scuola Superiore di Studi Universitari e di Perfezionamento Sant'Anna
  • Universita degli Studi di Genova
  • Universitaire Ziekenhuizen KU Leuven
  • Università degli Studi 'G. d'Annunzio' Chieti e Pescara

Registry information

Official study title

Head&Neck Application of Novel Computer-assisted Endoscopy

Acronym: H&NANCE

Important dates

Study start
2026
Primary completion
2027
Study completion
2028
First posted
May 19, 2026
Registry last updated
May 19, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.