Advanced OCT and Adaptive Optics Imaging in Retinal Disease (The ACAD Study)

The objectives of this study include using the new technology of SS-OCT (swept source optical coherence tomography) to evaluate morphological abnormalities of the vitreous, retina and choroid and to assess the repeatability of retinal and choroidal thickness measurements in retinal disease using SS-OCT. A secondary objective is to use the new imaging modality of adaptive optics to directly visualize photoreceptor mosaics and microvasculature in eyes with retinal and choroidal disease.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

NIHR Clinical Research Facility - Moorfileds Eye Hospital

London, EC1V 2PD, United Kingdom

About this study

Diseases affecting the vitreous, retina and choroid are among the commonest causes of sight-loss and vision impairment in England and Wales.

These diseases may display a wide range of pathological features including vitreous, retinal and subretinal haemorrhage; macular fluid; choroidal inflammation and choroidal masses.

The retina is a 'window to the brain' and there is increasing evidence that neurodegenerative disorders such as Multiple Sclerosis, Parkinsons Disease and Alzheimers Disease have retinal manifestations which may have prognostic implications, afford earlier diagnosis, and potentially act as surrogate endpoints for treatment trials.

In 2012, a further advance in OCT technology was brought to market with the arrival of the first commercial available swept-source OCT (SS-OCT) device (the Topcon DRI OCT). SS-OCT technology uses a tuneable laser light source with a longer wavelength of light (typically 1040-1050 nm central wavelength) than the light sources seen in more conventional SD-OCT devices. This leads to greater tissue penetration with less backscatter from the RPE, producing images of the choroid with greater resolution with fast image acquisition speeds (100,000 A scans/s) and longer line scan lengths. The ability to take rapid scans with the only commercially available SS-OCT device (the DRI, Tocon Inc. Paramus, NY, USA) also enhances image quality by line scan averaging capability.

The high axial resolution of OCT allows discrimination of the distinct retinal layers that are affected differentially in different diseases. More direct visualisation of the photoreceptor layer is afforded by use of an Adaptive Optics Scanning Light Ophthalmoscope (AOSLO), which provides excellent lateral resolution and allows direct visualisation of the cone and rod photoreceptor mosaics in vivo by correcting for ocular aberrations and resulting in a lateral comparable with histopathological sections.

In this study AO images will be correlated with SD- and SS-OCT and used to comprehensively assess the integrity of the photoreceptor mosaic. Furthermore AO and OCT will be used to measure nerve fibre layer loss and optic disc changes if relevant to the disease.

The imaging modalities used in this study will be spectral domain optical coherence topography (SD-OCT), swept source optical coherence tomography (SS-OCT), and adaptive optics scanning light ophthalmoscope (AOSLO)

The study will examine 300 patients (up to 600 eyes) in a single visit with a further Adaptive Optics (AO) imaging taken in a subset of patients (up to 200).

Patients in whom AO imaging was possible from a technical perspective will be invited back for further imaging after 6-12 months (at a standard NHS follow up visit) to probe longitudinal changes.

An examiner will scan the participants study eye(s) on the same day on each of the 3 imaging modalities SD-OCT, SS-OCT and AOSLO.

Finally a questionnaire will be used to explore whether participants preferred one OCT imaging modality over the other (SS-OCT vs SD-OCT).

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients attending Moorfields Eye Hospital with a diagnosis of diseases of the vitreous, retina or choroid in at least one eye including but not restricted to:
  • Vitritis
  • Vitreomacular interface abnormalities including macular hole
  • Age-related macular degeneration
  • Diabetic macular oedema and retinopathy
  • Other causes of macular oedema
  • Inherited retinal dystrophies
  • Inherited macular dystrophies
  • Posterior Uveitis (infectious and non-infectious)
  • Retinal nerve fibre layer loss (eg due to glaucoma)
  • Patients with neurodegenerative diseases such as multiple sclerosis for which there is previous literature identifying retinal/choroidal abnormalities referred by Consultant Neurologists within UCL Partners
  • Male or female aged 18 years old or over.
  • Ability to understand nature/purpose of study and to provide informed consent
  • Ability to undergoing imaging
  • Ability to follow instructions and complete study

Exclusion criteria

  • History of previous significant ocular trauma
  • Any condition which, in the investigator's opinion, would conflict or otherwise prevent the subject from complying with the required procedures, schedule or other study conduct.

Treatment and study plan

Swept-source optical coherence tomography (SS-OCT)

Device

The SD-OCT provides faster images and the ability to scan more of the central retina (macula). SD-OCT simultaneously measures multiple wavelengths of reflected light across a spectrum generating up to 40,000 A-Scans (axially sample points) per second. This allows the generation of 3 dimensional faster based volumetric images of the retina. The Spectralis OCT utilises real-time hardware eye tracking to resample lines scan enhancing the signal to noise ratio by improving the image quality.

The swept-source OCT (SS-OCT) uses a tuneable laser light source with a longer wavelength of light (typically 1040-1050 nm) that the light source seen in more conventional SD-OCT devices. The tissue penetration and resolution is greater with fast acquisition speeds and longer line scan lengths.

Other names: Spectral Domain coherence topography (SD-OCT), Adaptive Optics Scanning light ophthalmoscope (AOSLO)

Primary outcomes

  1. 3 repeated measurements of choroid + retinal thickness using SD-OCT and SS-OCT and optic nerve head imaging

    Time frame: 3 years

Secondary outcomes

  1. Percentage concordance and Kappa statistics of detection of morphological abnormalities in widefield OCT and conventional filed OCT (Spectralis OCT)

    Time frame: 3 years

  2. Repeated measures of photoreceptor mosaic integrity and microsvasculature (subset of patients only) at 2 visits

    Time frame: 3 years

Sponsors and collaborators

Lead sponsor

Moorfields Eye Hospital NHS Foundation Trust

Other

Registry information

Official study title

A Prospective Study to Evaluate Swept-Source OCT and Adaptive Optics Imaging of Diseases of the Vitreous, Retina and Choroid

Acronym: ACAD

Important dates

Study start
2015
Primary completion
2019
Study completion
2020
First posted
Jul 11, 2016
Registry last updated
Sep 9, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.