In this trial, Respiratory Motion Guided (RMG) 4DCBCT will be implemented for the first time on lung cancer patients. RMG-4DCBCT adapts the image acquisition as the patient's breathing changes (i.e. if the patient breathes faster, imaging data is acquired faster).
By adapting the acquisition to the dynamic patient, personalised images of a patients lungs are able to be acquired for radiotherapy treatments.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Liverpool, New South Wales, 2170, Australia
Four dimensional cone beam computed tomography (4DCBCT) continues to play a pivotal role in the safe delivery of radiotherapy treatments for lung cancer patients. 4DCBCT meets exacting tumour localisation requirements by allowing radiation therapists to measure the tumour as a patient breathes (4D=volumetric images plus respiratory induced tumour motion). Despite the success of 4DCBCT to date, it suffers from relatively poor image quality, very long scan times (4min) and higher imaging doses than are necessary. The primary reason for these problems is that although the purpose of 4DCBCT is to acquire information about tumour motion due to respiration, there is no feedback from the patients breathing signal to adapt and optimise the image acquisition process. This clinical trial is a phase 1 first in human's pilot study and the aim is therefore to prove feasibility of RMG-4DCBCT, not necessarily efficacy. As such, patient scans will be acquired across a broad range of patient breathing conditions to optimise the RMG-4DCBCT technique and also to plan a hypothesis driven clinical trial to follow.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Images are acquired and assessed offline
Time frame: 2 years
This will be achieved by performing (offline) analysis of the RMG-4DCBCT images obtained and scoring them on a scale of one (excellent quality for image guidance) to three (unsuitable for image guidance).
Time frame: 2 years
Using RMG-4DCBCT scans acquired across a broad range of patients for the first time we will determine if there is a link between image quality and the patients' breathing conditions. This information will be used to improve the prototype.
University of Sydney
Other
ADAPT: Adaptive CT Acquisition for Personalised Thoracic Imaging: A Phase 1 Pilot Study on the Use of Respiratory Motion Guided 4DCBCT for Lung Cancer Radiotherapy
Acronym: ADAPT
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03931356
Cancer, Lung, Lung Diseases
Brest, France
View Trial DetailsNCT06035731
Anxiety Depression, Breast Diseases
Nice, France
View Trial DetailsNCT03301493
Adenocarcinoma, Breast Diseases
Salzburg, State of Salzburg, Austria
View Trial DetailsNCT05227261
Adenocarcinoma, Breast Diseases
Hanoi, Vietnam
View Trial Details