CHU Montpellier
Montpellier, 34295, France
NCT Number: NCT02561975
An injury of haematosis in post ischemic chronic heart failure limits the clinic tolerance.
There is a correlation between injury of pulmonary diffusing, chronic heart failure intensity and aerobic physic ability evaluated by an heart-rate maximal exercise tolerance test (VO2 max). This injury is a new follow-up parameter of cardiac function for the adult.
The nature of damage (vascular or membrane) can be determined by the measure of double pulmonary diffusing capacity to carbon monoxide (CO) associated to nitric oxide (NO).
Today, in chronic heart failure consecutive to a congenital heart disease, there is no data on evolution of membrane and capillar factors.It is impossible to predict if membrane damage will be the best factor correlated to the VO2max in patients suffering from complex congenital heart disease.
Assessing these parameters could be an comparative evaluation of heart-rate exercise tolerance test with VO2max and an early control of his damage without risks related to heart-rate maximal exercise and independently of age, sex, hemoglobin, type of heart disease.These results would have an early prognostic value that would permit to refine the follow-up and the treatment.
The main objective of this trial is to assess the statistic correlation between the membrane injury of alveolar-capillary diffusing at rest and aerobic physic ability restriction in children and adults suffering from complex congenital heart disease.
Looking for future studies?
Notify Me8 year and older
All sexes
Interventional
Not applicable
Montpellier, 34295, France
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Measure of double pulmonary diffusing will be done as the single-breath test: the patient will be seated and connected to device by an oral tip. Measure begins by a maximal inhalation of a gas mixture (0.28% of CO, 14% of He, 21% of O2,450 ppm of NO/N2 and 40ppm of NO).After, the patient will maintain an apnea of 4 secondes and will breathe out in oral tip until his residual capacity.
With the expired air, some parameters will be assessed:
Time frame: at the time of evaluation at rest (15 minutes before exercise)
membrane ductance (Dm) is assessed by double pulmonary diffusing at rest
Time frame: at the time of evaluation at rest (15 minutes before exercise) and 3 minutes after the end of a maximal exercise
capillary pulmonary volume 3 minutes after the end of a maximal exercise minus capillary pulmonary volume at rest
Time frame: at the time of evaluation at rest (15 minutes before exercise)
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO and Dm/Vc
Time frame: 3 minutes after the end of a maximal exercise
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO et Dm/Vc
Time frame: 10 minutes after the end of a maximal exercise
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO et Dm/Vc
Time frame: at the time of evaluation at rest (15 minutes before exercise)
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO and Dm/Vc
Time frame: at the time of evaluation at rest (15 minutes before exercise)
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO and Dm/Vc
Time frame: 3 minutes after the end of a maximal exercise
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO et Dm/Vc
Time frame: 3 minutes after the end of a maximal exercise
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO et Dm/Vc
Time frame: 10 minutes after the end of a maximal exercise
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO et Dm/Vc
Time frame: 10 minutes after the end of a maximal exercise
parameters assessed during measure TLCO/TLNO of double diffusing are TLCO, TLCO/VA, TLNO, TLNO/VA Vc, Dm, Vc/VA, Dm/VA, TLNO/TLCO et Dm/Vc
University Hospital, Montpellier
Other
Acronym: CAR-DIFF
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05767385
Cardiovascular Abnormalities, Cardiovascular Diseases
San Francisco, California, United States
View Trial DetailsNCT05943275
Chronic Right Heart Failure, Complex Congenital Heart Disease
Montpellier, France
View Trial DetailsNCT04810013
Complex Congenital Heart Disease
Tübingen, Germany
View Trial DetailsNCT07572435
Complex Congenital Heart Disease
Seoul, South Korea
View Trial Details