Zhejiang university
Hangzhou, Zhejiang, 310000, China
NCT Number: NCT02590913
The purpose of this study is to investigate the metabolic and endocrine responses during 3 hour after taking 75g fructose or glucose in young Chinese.
Looking for future studies?
Notify Me19 year–39 year
All sexes
Interventional
Not applicable
Hangzhou, Zhejiang, 310000, China
The study was a double-blinded, randomized, crossover trial. Twenty healthy volunteers were randomized to two groups: group A (300ml of 22.5% glucose) and group B (300ml of 22.5% fructose).Volunteer was randomized into either group A or B, after an 8-h overnight fasting, took 300ml of solution at 0830 within 5 minutes. After one-week washout period, volunteer was crossed over for either group B or A. each intervention, venous blood was collected at 0h, 0.5h, 1h, 2h, and 3h and blood pressure was tested at 0h, 1h, 2h, and 3h.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
75g fructose is dissolved in 300 ml water.After overnight fasting, 300ml of solution at 0830 within 5 minutes is taken by volunteers
75g glucose is dissolved in 300 ml water.After overnight fasting, 300ml of solution at 0830 within 5 minutes is taken by volunteers
Time frame: 3 hours
Serum uric acid concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by DiaSys Diagnostic Systems (Shanghai) Co., Ltd
Time frame: 3 hours
Blood pressure was measured at Zhejiang University Hospital by the research workers who were blind to the groups within 3 hours blood collection.
Time frame: 3 hours
Serum glucose level was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd
Time frame: 3 hours
Serum nitric oxide concentration was measured using NO assay kit (Nanjing Jiancheng Technology Co., Lte., Nanjing, China) by the research workers who were blind to the groups.
Time frame: 3 hours
Enzymatic activity of aldose reductase in serum was measured using ELISA kit (Shanghai Changjin Biology Co., Lte., Shanghai, China ) by the research workers who were blind to the groups.
Time frame: 3 hours
Enzymatic activity of phosphofructokinase in serum was measured using ELISA kit (Shanghai Changjin Biology Co., Lte., Shanghai, China ) by the research workers who were blind to the groups .
Time frame: 3 hours
Serum insulin concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd
Time frame: 3 hours
Serum insulin-c concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd
Time frame: 3 hours
Triglyceride concentration in serum was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd
Time frame: 3 hours
Total cholesterol concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd
Time frame: 3 hours
High-density cholesterol was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd.
Time frame: 3 hours
Low-density cholesterol concentration was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd.
Time frame: 3 hours
Enzymatic activity of lactate dehydrogenase was analyzed on HITACHI 7020 chemistry analyzer using enzyme-based colorimetric test or colorimetric test supplied by Diasys Diagnostic Systems (Shanghai) Co., Ltd.
Zhejiang University
Other
Acute Metabolic and Endocrine Responses of Glucose and Fructose in Healthy Young Subjects: A Double-blinded, Randomized, Crossover Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT06702423
Healthy
London, United Kingdom
View Trial DetailsNCT07223164
Healthy
Irvine, California, United States
View Trial DetailsNCT05595902
Healthy
Kadıköy, Istanbul, Turkey (Türkiye)
View Trial Details