Inspiratory muscle training has been an important part of pulmonary rehabilitation program directed at patients with COPD. It can increase respiratory muscle strength, relieve dyspnea ,improve the quality of life in COPD patients. However, there is no uniform standard for the intensity of inspiratory muscle training. By comparing a series of indexes, such as maximal inspiratory pressure, maximal expiratory pressure, degree of dyspnea and exercise capacity before and after the training under different intensity, a large number of literatures have explored the appropriate intensity of inspiratory muscle training. But to date, there are few studies about the effects of different intensity of inspiratory muscle training on respiratory physiological mechanism. It has been shown that inspiratory muscle training may be more beneficial to improve the pulmonary rehabilitation effect of COPD patients with inspiratory muscle weakness. So it is not clear whether there is a difference in respiratory physiology between patients with normal inspiratory muscle strength and those with lower inspiratory muscle strength. Respiratory central drive, as an important physiological index, which can be reflected by minute ventilation volume, mouth pressure, mean inspiratory flow and diaphragm electromyography,is closely related to the symptoms and the severity of the disease.Therefore,the purpose of this study was to investigate the changes of respiratory mechanics and central drive in COPD patients at different inspiratory loads, and at the same loads between patients with and without respiratory muscle weakness.That can provide more evidential evidence for setting up the intensity of inspiratory muscle training.
Looking for future studies?
Notify Me40 year–75 year
All sexes
Interventional
Not applicable
Guangzhou, Guangdong, 510282, China
The patients with COPD will be admitted in one intervention groups(performing on threshold loading device).Before using threshold loading device, we will measure the relevant parameters of lung volume, respiratory flow,diaphragm electromyogram, central drive mechanical and other baseline index.Then incremental inspiratory load will be applied to investigate the effects of inspiratory load on the above mentioned respiratory mechanics parameters.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patients with acute cardiovascular event and severe cor pulmonale. Patients with poor compliance. An Other causes of diaphragmatic dysfunction
inspiratory load ranges between 10 and 40 cm water column (cmH2O)or intolerable to the patient, each load increment for 5cm water column.
Time frame: Change from baseline in diaphragm electromyogram at the load of 10cm water column (cmH2O).(1 minutes later,3 minutes later,5 minutes later,7 minutes later,9 minutes later,11 minutes later, 13 minutes later)
Diaphragmatic function can be assessed by diaphragm electromyogram (EMGdi), which reflect the physiological activity of the diaphragm and indicate functional status of the central drive.
Time frame: Change from baseline in respiratory pressure at the load of 10cm water column (cmH2O).(1 minutes later,3 minutes later,5 minutes later,7 minutes later,9 minutes later,11 minutes later, 13 minutes later)
Respiratory pressure can be assessed by transdiaphragmatic pressure ( Pdi).
Time frame: Change from baseline in respiratory volume at the load of 10cm water column (cmH2O).(1 minutes later,3 minutes later,5 minutes later,7 minutes later,9 minutes later,11 minutes later, 13 minutes later)
Respiratory volume can be assessed by Tidal volume (VT).
Time frame: Change from baseline in degree of dyspnea at the load of 10cm water column (cmH2O).(1 minutes later,3 minutes later,5 minutes later,7 minutes later,9 minutes later,11 minutes later, 13 minutes later)
Difference in the degree of dyspnea can be measured by Borg index.
Time frame: Change from baseline in pulse oxygen saturation at the load of 10cm water column (cmH2O).(1 minutes later,3 minutes later,5 minutes later,7 minutes later,9 minutes later,11 minutes later, 13 minutes later)
Change in SpO2 can be recorded by noninvasive monitoring instruments.
Zhujiang Hospital
Other
Acute Effects of Incremental Inspiratory Loads on Respiratory Mechanics and Neural Respiratory Drive(NRD) in Patient With Stable Chronic Obstructive Pulmonary Disease(COPD).
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05984823
Chronic Disease, Chronic Obstructive Pulmonary Disease
Leicester, Leicestershire, United Kingdom
View Trial DetailsNCT05572333
COPD, Chronic Disease
Frankfurt, Germany
View Trial DetailsNCT03641235
Chronic Disease, Chronic Obstructive Pulmonary Disease
Bordeaux, France
View Trial DetailsNCT05984680
Chronic Disease, Chronic Obstructive Pulmonary Disease
Winston-Salem, North Carolina, United States
View Trial Details