Skip to main content
OpenTrials
Completed

NCT Number: NCT03995329

Acute Effects of a Heat-not-burn Tobacco Product on Pulmonary Function in Healthy Non Smokers.

IQOS ("I-Quit-Ordinary-Smoking,") is a type of "heat-not-burn" (HNB) tobacco product. There is evidence of a growing number of young people who try IQOS as a 'safe' alternative of cigarette. The effect of the acute exposure to IQOS smoke on pulmonary function of healthy non smokers has not been studied extensively.

Objectives: Evaluation of the acute effects of IQOS on pulmonary function,exhaled CO, O2 Saturation, arterial pressure and heart rate.

Methods: Healthy non smokers, underwent exhaled CO measurement, spirometry including flows, volumes and diffusion capacity, and measurement of their respiratory resistances at 5, 10 and 20 Hz (R5Hz, R10Hz and R20Hz) with the use of an impulse oscillometry system (IOS) before and after the use of an IQOS. Additionally heart rate and arterial blood pressure were also measured.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–55 year

Sex eligibility

Male

Study type

Interventional

Phase

Not applicable

Primary location

G Papanicolaou Hospital, Thessaloniki, Greece

Loading trial locations.

About this study

All participants underwent pulmonary function tests (PFT) (MasterScreen PFT, Jaeger, Wurzburg, Germany) and total respiratory resistances measurement with an impulse oscillometry system (IOS)( (Viasys Jaeger MasterScreen IOS system).From the basic pulmonary measurements (flows and dynamic lung volumes), Forced Expiratory Volume in 1 second (FEV1), Forced Vital Capacity (FVC), Tiffenau index (FEV1/FVC, FEV1%), Peak Expiratory Flow (PEF), Maximal Expiratory Flow (MEF) at 25%, 50%, and 75% of vital capacity, Functional Residual Capacity (FRC), Total Lung Capacity (TLC), Residual Volume (RV), Diffusion Capacity (DLCO) were measured. Each manoeuvre was repeated for at least three technically acceptable forced expiratory flow curves in order to attain the best results. Respiratory impedance at 5 Hz (Z5Hz) and respiratory resistance at 5, 10, and 20 Hz (R5Hz, R10Hz, and R20Hz, respectively), reactance at 5, 10, and 20 Hz and resonant frequency were assessed with IOS. Heart rate, saturation of O2 (oxymetry) and arterial blood pressure were also measured. Exhaled CO measurement (piCO Smokerlyzer,Bedfont Scientific Ltd, Kent, U.K.) was performed After smoking heated tobacco (IQOS): 5 minutes after smoking IQOS , they repeated again PFTs, IOS, exhaled CO heart rate, saturation of O2 (oximetry) and arterial blood pressure measurements.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Healthy male non smokers,
  • Age 18-55 years
  • receiving no medications
  • no co morbidity -

Exclusion criteria

  • aged <18 years
  • smokers or ex-smokers
  • receiving any medications
  • any co morbidity -

Treatment and study plan

IQOS

Other

Acute effects of IQOS on pulmonary function, oxygen saturation, exhaled CO, heart rate and arterial blood pressure.

Primary outcomes

  1. Forced Expiratory Volume in 1 second

    Time frame: immediately (max 5 min)

    Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in:Forced Expiratory Volume in 1 second (FEV1), (liters)

  2. Forced Vital Capacity

    Time frame: immediatly (max 5 min)

    Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in:Forced Vital Capacity (FVC), (liters)

  3. Tiffenau index

    Time frame: immediately (max 5 min)

    Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in:

    Tiffenau index (FEV1/FVC, FEV1%)

  4. Peak Expiratory Flow

    Time frame: immediately (max 5 min)

    Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in: Peak Expiratory Flow (PEF), (liters/second )

  5. Functional Residual Capacity (FRC)

    Time frame: immediately (max 5 min)

    Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in:Functional Residual Capacity (FRC), (liters)

  6. Total Lung Capacity (TLC)

    Time frame: immediately (max 5 min)

    Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in: Total Lung Capacity (TLC), (liters)

  7. Residual Volume (RV)

    Time frame: immediately (max 5 min)

    Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in: Residual Volume (RV), (liters)

  8. Diffusion Capacity (DLCO)

    Time frame: immediately (max 5 min)

    Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in: Diffusion Capacity (DLCO) ((mmol/min/kPa)

  9. Respiratory impedance

    Time frame: immediately (max 5 min)

    Total respiratory resistances measurement with an impulse oscillometry system (IOS)( (Viasys Jaeger MasterScreen IOS system) prior to smoking heated tobacco IQOS and 5 minutes after smoking IQOS were performed. The changes in: Respiratory impedance at 5 Hz (Z5Hz) (kPa/L/sec) were assessed

  10. Total respiratory resistances

    Time frame: immediately (max 5 min)

    Total respiratory resistances measurement with an impulse oscillometry system (IOS)( (Viasys Jaeger MasterScreen IOS system) prior to smoking heated tobacco IQOS and 5 minutes after smoking IQOS were performed. The changes in: respiratory resistance at 5 (R5Hz),10 Hz (R10Hz),20 Hz (R20Hz) (kPa/L/sec) were assessed

  11. Arterial Blood Pressure

    Time frame: immediately (max 5 min)

    Arterial Blood Pressure prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in Arterial Blood Pressure were measured (mmHg)

  12. Oxygen Saturation

    Time frame: immediately (max 5 min)

    Oxygen Saturation prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in Oxygen Saturation were measured by oximetry

  13. Heart rate

    Time frame: immediately (max 5 min)

    Heart rate prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in Heart rate were measured by oximetry

  14. Exhaled CO

    Time frame: immediately (max 5 min)

    Exhaled CO prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in Exhaled CO were measured by (piCO Smokerlyzer) (ppm)

Sponsors and collaborators

Lead sponsor

Aristotle University Of Thessaloniki

Other

Registry information

Important dates

Study start
2019
Primary completion
2019
Study completion
2019
First posted
Jun 24, 2019
Registry last updated
Jan 9, 2020

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.