Skip to main content
OpenTrials
Completed

NCT Number: NCT04073277

Acupuncture Needle Modified With Supercritical Fluid

Objective: To compare the differences in the needling sensation with acupuncture needles surface treated with nitrogen applied supercritical fluid (SCF-N) and stainless steel needles.

Materials and Methods: This was a double-blind prospective cohort study. The acupuncture needles were randomly used in this experiment, including the SCF-N-treated needles and the control stainless steel needles. LI 4 (Hegu) and LI 11 (Quchi) acupuncture points in the Yangming Large Intestine Meridian of Hand were treated. Physical electrical resistance , scanning electron microscopy, energy dispersive spectrometry, and visual analog scale score including the sensations of soreness, numbness, distention, and heaviness were assessed.

Completed

Looking for future studies?

Notify Me

Key information

Age range

20 year–40 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Kaohsiung Chang Gung Memorial Hospital

Kaohsiung City, 833, Taiwan

About this study

This was a double-blinded prospective cohort study. The acupuncture needles were first separated into two groups. One group of needles was subjected to SCF-N treatment while the other was not. The needles were then randomly analyzed with scanning electron microscope and energy dispersive X-ray spectroscopy to ensure quality and minimize experimental error. For each participant, one hand was randomly assigned to the treatment group with SCF-N-treated acupuncture needles and the other hand was assigned to the control group with the stainless steel needles. The time interval between the acupuncture treatment of the two groups was about two hours. In order to examine and distinguish the difference between the two groups, de-qi VAS score was recorded by the volunteers during needle insertion and the electrical resistance by electrical measurement.

The acupuncture needles used in this experiment, including the SCF-N-treated needles and the control stainless steel needles, were produced under the same conditions, in the same factory (Dong Bang acupuncture Inc.), and on the same day, to minimize experimental error.

The process of SCF treatment:. First, the stainless steel chamber and quartz carrier were sterilized using alcohol and autoclaving. Next, the needles were placed on the quartz carrier with the tip pointing upwards and then placed in the chamber and covered. Carbon dioxide was used to remove atmospheric components from the chamber and required volume of ammonia gas was passed. The pressure was increased up to 3000 pound per square inch(psi) and temperature up to 120℃. An hour later, the pressure was relieved and the process of SCF treatment completed. After completion of the treatment, the needles were then randomly selected for material analysis and electrical measurement. Following this, the needles were stored in a vacuum bag. This was done to reduce the influence of atmospheric contaminants on the needles after treatment, resulting in oxidation and rusting. Finally, there would be heterogeneous contact between the inorganic metal and the acupuncture needle. Hence, nitrogen was selected as the main agent for SCF treatment.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Healthy volunteer aged 20 to 40 years
  • Provided informed consent

Exclusion criteria

  • Women with pregnancy or breast feeding
  • Bleeding tendencies (platelet counts less than 20000 and/or thrombocytopenic purpura)
  • Volunteers with chronic medical conditions and anti-coagulants use
  • Volunteers with pacemakers
  • Fasting
  • Unwilling to provide informed consent

Treatment and study plan

SCF-N-treated needles

Device

The SCF-N-treated needles were used for acupuncture at LI 4 (Hegu) and LI 11 (Quchi) acupoints in the experimental groups..

Untreated needles

Device

he untreated needles were used for acupuncture at LI 4 (Hegu) and LI 11 (Quchi) acupoints in the control groups.

Primary outcomes

  1. Resistance of the meridian

    Time frame: immediately after acupuncture needling

    Electrical resistance was measured by applying a fixed electric current (110 µA) for 1 second and recording the I-V curve. A linear relationship of voltage=current x resistance was expected. The analyzer used in this experiment was Agilent B1500, a semi-conductor analyzer able to measure electrical resistance with high accuracy.

Secondary outcomes

  1. Modified Visual Analog Scale (VAS) Score

    Time frame: immediately after acupuncture needling

    The VAS score was used to assess the needling sensations of de-qi, i.e. distension, soreness, heaviness, or numbness. VAS score 0 indicated no sensation, while VAS 10 indicated the strongest sensation.

Sponsors and collaborators

Lead sponsor

Chang Gung Memorial Hospital

Other

Registry information

Official study title

Study on Improving Acupuncture Needles and Physical Properties of Acupoints With Supercritical Fluid

Important dates

Study start
2017
Primary completion
2018
Study completion
2018
First posted
Aug 29, 2019
Registry last updated
Aug 29, 2019

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.