NCT Number: NCT03124693
Accuracy of Noninvasive Hemoglobin Measurement (SpHb) Using Rainbow DCI Pulse Oximeter Sensor
In this study, the concentration of hemoglobin within the subject's blood is affected by fluid status changes. The fluid status is affected by fluid loss during surgery for hospitalized study subjects or controlled administration of fluids intravenously for healthy study volunteers. The accuracy of a noninvasive hemoglobin sensor(s) will be assessed by comparing with blood sample analysis.
Looking for future studies?
Notify MeKey information
Who can participate
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Healthy Volunteers
Inclusion criteria
- Has physical status between ASA 1 or 2
- Able to communicate in English
Exclusion criteria
- Pregnant or sexually active without birth control.
- Hemoglobin less than 11g/dL
- Known alcohol or drug abuse
- Skin abnormalities affecting the digits such as psoriasis, eczema, angioma, scar tissue, burn, fungal infection
- Nail polish
- Head injury with loss of consciousness within the last year
- Known neurological and psychiatric conditions.
- Known concurrent chronic usage of psychoactive or anti-convulsive drugs within the last 90 days, or use in the last 7 days (i.e. tricyclic antidepressants, MAO inhibitors, lithium, neuroleptics, anxiolytics or antipsychotics. Except SSRIs
- Subject has any medical condition which, in the judgement of the investigator, renders them inappropriate for participation in this study, such as Reynauds syndrome
- Hypertension: Systolic BP >= 140 mmHg or Diastolic BP >= 90 mmHg
- Baseline heart rate <50 beats per minute
Surgical Subjects
Inclusion criteria
- Age > 18 years old
- Scheduled for surgery requiring frequent schedule blood draws as a part of their routine care
Exclusion criteria
- Pregnant or lactating women
- Skin abnormalities at the planed application sites that would interfere with transilluminating the finger, or other measurement sites, like burns, scar tissue, nail polish, infections etc.
Treatment and study plan
Primary outcomes
-
Accuracy of Sensor by Arms Calculation
Time frame: Up to 24 hours
Accuracy will be determined by comparing the noninvasive hemoglobin measurement of the pulse oximeter to the hemoglobin value obtained from a blood sample and calculating the arithmetic root mean square (Arms) error value.
Sponsors and collaborators
Lead sponsor
Masimo Corporation
Industry
Registry information
Important dates
- Study start
- 2008
- Primary completion
- 2008
- Study completion
- 2008
- First posted
- Apr 24, 2017
- Registry last updated
- Jun 12, 2017
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Related clinical trials
Published trials that share one or more normalized conditions with this study.
Accuracy of Noninvasive Pulse Oximeter Measurement of Hemoglobin for Rainbow DCI Sensor
NCT03124901
Healthy, Surgery
Irvine, California, United States
View Trial DetailsTumor-Derived FGF19
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsAI Chatbot for HPV Vaccine Literacy Among Caregivers in Japan
NCT06702423
Healthy
London, United Kingdom
View Trial DetailsValidation of the Masimo Irregular Heartbeat Detection Algorithm in Participants Without Cardiovascular Disease
NCT07223164
Healthy
Irvine, California, United States
View Trial Details