Skip to main content
OpenTrials
Completed

NCT Number: NCT05254587

Accuracy of IOLMASTER 700 Total Keratometry (TK)

This is a multicenter study to compare the accuracy of IOL calculations in post-laser vision corrected eyes that are about to undergo or have undergone cataract surgery.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Empire Eye & Laser Center, Bakersfield, California, United States

Loading trial locations.

About this study

This is a multicenter study to compare the accuracy of IOL calculations using 4 different IOL calculation methods (Haigis TK, ASCRS calculator, Barrett True K with classic K, and Barrett True K TK) performed using the preoperative biometry data from post-laser vision correct eyes that are about to undergo or have undergone cataract surgery.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Adults, 18 years of age or older at the time of cataract surgery.
  • Patient has had LVC and IOL cataract surgery within 3 years or is scheduled to undergo IOL cataract surgery performed for the treatment of visually significant cataracts.

Note: The only IOLs permitted for use in this study are Monofocal (ZCBOO, LI61AO, SN60WF, SA60WF, MX60E) and Toric Lenses (Tecnis 2 ZCU, ZCT, SN6ATx, SA6ATx, MX60ET).

  • Best corrected distance visual acuity (BCDVA) potential of 20/30 or better (as measured by Retinal Acuity Meter (RAM) or Potential Acuity Meter (PAM).
  • Patients who have a manifest refraction that is myopic or hyperopic after previous LVC.
  • Patients that have biometric measurements (including Axial Length) for the IOL cataract surgery that were performed preoperatively with the IOLMaster700, including Barrett True K /TK.
  • Signed and received a copy of the signed written informed consent (pertain to the prospective subjects only).
  • For prospective patients, willingness and ability to comply with schedule for follow-up visits and postoperative evaluations.

Exclusion criteria

  • Patients with a history of any of the following:
  • Corneal pathology - Epithelial Basement Membrane Dystrophy (EMBD), Irregular Astigmatism, Decentered LASIK/PRK, Radial Keratotomy (RK), Fuchs Dystrophy
  • Retinal pathology - Visually significant Epiretinal Membrane (ERM) with loss of foveal contour, Large/ Medium Drusen, Cystoid Macular Edema (CME), History of Retinal Detachment
  • Optic neuropathy
  • Advanced glaucoma
  • Amblyopia
  • Strabismus
  • Relative Afferent Pupillary Defect (RAPD) indicating an optic neuropathy.
  • Patients with a previous history of small incision lenticule extraction (SMILE) surgery and/or glaucoma filtering procedure (defined as tubes or trabeculectomy) other than photorefractive keratectomy (PRK) or LASIK.
  • Patient who had to undergo A-scan measurement to retrieve Axial Length (AL) values.
  • Patient has had LVC and IOL cataract surgery within 3 years or is scheduled to undergo IOL cataract surgery performed for the treatment of visually significant cataracts with the presence or intention of implanting a multifocal, extended depth of focus, accommodating and light adjustable lens (such as, but not limited to, TFAT / TFNT; DAT / DFT; ICB00/DIB/DIU/DAT; ZXT; DFW; SN6AD1; AT-50; RxSIGHT).
  • Patients in whom the study eye experiences any intraoperative surgical complications or complex cataract surgeries (vitrectomy, corneal suturing).
  • Patients with previous LVC where one eye was treated for myopia and the other eye was treated for hyperopia.
  • Patient is participating in another study.

Treatment and study plan

IOLMASTER 700 TK

Device

4 different intraocular lens (IOL) calculation methods (Haigis TK, ASCRS calculator, Barrett True K Classic K, Barrett True K TK) will be performed using the preoperative biometry and post operative refraction data.

Primary outcomes

  1. Total Keratometry Accuracy Assessment

    Time frame: 4 Weeks

    Subjects utilizing Total Keratometry within (+/- 0.50 D, +/- 0.75 D, +/- 1.00 D) compared to the proportion of subjects utilizing traditional keratometry readings.

Sponsors and collaborators

Lead sponsor

Advanced Vision Care

Other

Collaborators

  • Clinical Research Consultants, Inc.

Registry information

Official study title

Accuracy of IOLMASTER 700 Total Keratometry (TK) in Patients Undergoing Post-Laser Vision Correction Cataract Surgery

Important dates

Study start
2022
Primary completion
2024
Study completion
2024
First posted
Feb 24, 2022
Registry last updated
Feb 20, 2026

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.