Investigational BD FACSPresto System
DeviceBlood samples will be tested on the BD FACSPresto system for CD4 absolute count (CD4Abs), %CD4, and Hb concentration.
NCT Number: NCT02396355
The enumeration of T lymphocytes positive for the CD4 antigen is used to determine the immune status of patients with, or suspected of developing, immune deficiencies such as AIDS. The BD FACS Presto™ is an investigational automated system for in vitro diagnostic use in performing the direct enumeration of CD4 absolute count, CD4 percentage of lymphocytes, and hemoglobin (Hb) concentration in human whole blood.
This is a prospective study to determine the relative bias between the investigational BD FACS Presto system and the predicate BD FACS Calibur with BD Tritest system in their determination of absolute CD4, % CD4, and Hb concentrations.
Looking for future studies?
Notify MeAll sexes
Observational
National AIDS Research Institute, Pune, Maharashtra, India
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Blood samples will be tested on the BD FACSPresto system for CD4 absolute count (CD4Abs), %CD4, and Hb concentration.
Blood samples will be tested on the predicate, currently marketed device. For CD4Abs and %CD4 measurement, the BD FACSCalibur flow cytometer will be used with BD Multiset software version 1.1 or later and BD Tritest CD3/CD4/CD45 reagent with Trucount tubes.
Blood samples will be tested for hemoglobic concentration on the predicate, currently marketed Sysmex hematology analyzer KX-21
Time frame: assayed upon sample collection
The primary endpoint is the bias (expected difference) between the investigational vs. predicate system measured as absolute CD4 lymphocyte count and %CD4 in peripheral venous blood from a minimum of 400 specimens with valid results tested at three or more external sites.
Time frame: assayed upon sample collection
The bias (expected difference) between the investigational vs. predicate system measured as absolute CD4 lymphocyte count and %CD4 in capillary blood from a minimum of 400 specimens with valid results tested will be determined at three or more external sites.
Time frame: assayed upon sample collection
The bias (expected difference) between the investigational BD FACSPresto system vs. predicate (Sysmex KX-21 hematology analyzer) will be determined for hemoglobin concentration using venous blood and capillary blood.
Becton, Dickinson and Company
Industry
Accuracy Evaluation of the BD FACS Presto System: Instrument, Software and BD CD4/%CD4/Hb Cartridge Assay
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04983030
Acquired Immunodeficiency Syndrome, Blood-Borne Infections
Los Angeles, California, United States
View Trial DetailsNCT05031819
Acquired Immunodeficiency Syndrome, Blood Pressure
Uyo, Akwa Ibom State, Nigeria
View Trial DetailsNCT04772469
Acquired Immunodeficiency Syndrome, Blood-Borne Infections
Siaya, Kenya
View Trial DetailsNCT02639754
Acquired Immunodeficiency Syndrome, Blood-Borne Infections
Sofia, Bulgaria
View Trial Details