Cerba Xpert
Frépillon, Île-de-France Region, 95000, France
NCT Number: NCT06623058
As part of the CE marking of a hepatitis C diagnostic kit, the South Korean manufacturer Bioneer wishes to set up a performance study in France in accordance with the IVDR (RE 2017/746).
Cerba Xpert CRO of the Cerba Healthcare group promoted this performance study by setting up a prospective collection of blood samples from patients suffering from the virus hepatitis C and whose viral load is positive. This prospective collection will be carried out in 4 laboratories of the Cerba Healthcare group.
Trial opening soon.
Get Notified18 year and older
All sexes
Observational
Frépillon, Île-de-France Region, 95000, France
Viral hepatitis are primarily human systemic infections caused by viruses hepatic diseases which cause damage to the liver by hepatocyte infection of the virus and/or a host immune response to the virus. (1) Hepatitis is grouped into five types (A, B, C, D, E) and is mainly transmitted by parenteral, sexual and fetomaternal.(2) The hepatitis C virus (HCV) was discovered in 1989.(3) It is an RNA virus that belongs to the family Flaviviridae.(4) Infection with the hepatitis C virus is characterized by clinical signs such as such as jaundice, asthenia, anorexia. In approximately 30% (15% to 45%) of infected people, the virus is spontaneously eliminated within six months following infection, without any treatment. (5) For the remaining 70% (55% to 85%), the infection will progress to a chronic form. In patients chronic, the risk of cirrhosis is 15% to 30% in the 20 years following infection. (5) A assessment of liver damage and virus replication in the blood is made before starting treatment.(6) Detection/quantification of HCV RNA in serum or plasma must therefore be available before to initiate antiviral treatment. HCV RNA must be tested for by a sensitive test giving a result viral load expressed in IU/ml and Log IU/ml. (6) Monitoring of response to treatments is done also by the detection of viral RNA, particularly at 12 weeks post-treatment where a viral load undetectable is a sign of effective treatment and healing. (6) On the European market, quantitative determination of hepatitis C viral load as part of Diagnosis and monitoring of the disease is done by real-time PCR which is the reference technique.(7) As part of routine care, there are several diagnostic PCR kits that can be used on plasma or serum. Today, there are no CE approved PCR kits that allow the quantification of viral RNA at the both serum and plasma. Our study will make it possible to evaluate the performance of the Bionner kit PCR kit ACCUPOWER Quant Kit Bioneer Existation™FA 96/384 on serum and plasma of affected patients hepatitis C.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
The patient to be included in this study must be able to understand the purpose of the research, in order to to give free and informed consent.
Exclusion criteria
Protected subject: adult under guardianship, curatorship or other legal protection, deprived of liberty by judicial decision or administrative Subject participating in a clinical study/receiving investigational treatment
-
Time frame: 4 months
The submitted protocol is carried out as part of a 'commutability' study, that is to say for Compare two matrix types on the Accupower ® HCV Quant Kit Bioneer Existence™FA 96/384. Indeed, for these two matrices to be claimed in the IFU of the kit it is necessary to prove that the two matrices give the same result.
The planned size of the evaluable cohort is 45 patients included over a period of 4 month. This size is justified by the recommendations of the applicable CLSI EP09 guide.
This guide details the use of several mathematical models that guarantee robust analysis even on a small cohort size. The operating methodology of the results is detailed below, taken from the recommendations of the CLSI EP09 guide
Contact information is provided by the study sponsor or research team.
CerbaXpert
Other
Acronym: BIOPERF-HCV
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07631559
Behavior, Blood-Borne Infections
San Francisco, California, United States
View Trial DetailsNCT07560046
Acquired Immunodeficiency Syndrome, Blood-Borne Infections
View Trial DetailsNCT07317687
Bacterial Infections, Bacterial Infections and Mycoses
Harpers Ferry, West Virginia, United States
View Trial DetailsNCT06799702
Blood-Borne Infections, Chemically-Induced Disorders
Colbert, Georgia, United States
View Trial Details