Laserklinik Karlsruhe
Karlsruhe, D-76133, Germany
NCT Number: NCT00990431
Ablative fractional lasers were introduced for treating facial rhytides in an attempt to achieve results comparable to traditional ablative resurfacing but with fewer side effects. However, there is conflicting evidence on how well this goal has generally been achieved as well as on the comparative value of fractional CO2 and Er:YAG lasers. The present study compares these modalities in a randomized controlled blinded split-face study design:
28 patients were enrolled and completed the entire study. Patients were randomly assigned to receive a single treatment on each side of the peri-orbital region, one with a fractional CO2 and one with a fractional Er:YAG laser. The evaluation included Fitzpatrick wrinkle score, profilometric measurement of wrinkle depth (both before and 3 months after treatment) as well as assessment of side effects and patient satisfaction (1, 3, 6 days and 3 months after treatment).
Looking for future studies?
Notify Me40 year–55 year
All sexes
Interventional
Phase 4
Karlsruhe, D-76133, Germany
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The CO2 laser (Fraxel Re:pair, Solta Medical Inc., Hayward, CA) employs disposable tips with a diameter of 7 mm and 15 mm, the smaller being used for the peri-orbital region. The laser beam is delivered through multiple deflective and refractive elements and focused to a spot size of approximately 120 µm in diameter at incidence to the skin to deposit an array of laser beams across the surface. Pulse energy varies from 5 to 70 mJ and density from 5 to 70 %. The pulse duration is 10 msec. In the present study, patients received two passes at 15 mJ (1st pass) and 20 mJ (2nd pass), respectively, with a total density of 20 %.
The Er:YAG laser used in this study has a fractional handpiece (MCL 30 Dermablate, Asclepion Laser Technologies GmbH, Jena, Germany). By means of a microlens array the laser beam is divided into 13 x 13 small spots with 250 µm diameter each, spread over an area of 13 x 13 mm. A coverage of 5 % of the skin is achieved with a single pass. The pulse duration is 400 μsec. In this trial, we performed 4 passes (resulting in coverage of 20 % of the treated skin) with a total fluence of 60 J/cm² and pulse stacking (6 stacked pulses) to optimize thermal exposure.
Time frame: 3 months
Time frame: 3 months
Time frame: 3 months
Laserklinik Karlsruhe
Other
Ablative Fractional Lasers (CO2 and Er:YAG): A Randomized Controlled Blinded Split-face Trial of the Treatment of Peri-orbital Rhytides
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.