Niti-S SPAXUS Stent
DeviceEndoscopic Ultrasound-Guided Transluminal drainage
NCT Number: NCT02730663
The purpose of this study is to evaluate the safety and effectiveness of endoscopic ultrasound (EUS)-guided transluminal drainage with 'Niti-S SPAXUS Stent' for the treatment of pancreatic pseudocyst.
Looking for future studies?
Notify Me19 year and older
All sexes
Interventional
Not applicable
Soon Chun Hyang University Hospital Bucheon, Bucheon-si, Gyeonggi-do, South Korea
'Niti-S SPAXUS Stent' is a newly designed lumen-apposing fully covered self-expandable metal stent. It is indicated for use in patients with pancreatic pseudocyst. Consecutive subject data should be collected at discharge, stent removal (day 30 or 60), and day 20 post Niti-S SPAXUS stent removal.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Endoscopic Ultrasound-Guided Transluminal drainage
Time frame: at stent removal (Day 30 or Day 60)
Clinical success is defined as ≥50% decrease in pancreatic pseudocyst size measured on Computed Tomography (CT)
Time frame: Day 1
Technical success is defined as successful placement of the Niti-S SPAXUS stent across the gastric(or duodenal) wall to the pseudocyst with visualization of the pseudocyst fluid drainage through the stent by endoscopy.
Time frame: up to 60 days (at stent removal, Day 30 or 60)
Stent lumen patency will be evaluated by endoscopy.
Time frame: up to 60 days (at stent removal, Day 30 or 60)
Stent removal success is defined as successful removal of the Niti-S SPAXUS stent using a standard endoscopic forceps or snare.
Time frame: 1 day
Procedure time is measured as time from insertion until removal of endoscope. Procedure time 1: The time from the moment that the endoscope is inserted into the oral cavity to the time point at which the endoscope is removed. (sec) Procedure time 2: The time from the puncture time to the point at which the ultrasound endoscope was removed. (sec)
Time frame: up to 90 days (at Day 20 post stent removal)
The incidence of serious adverse events related to the procedure or the Niti-S SPAXUSTM stent is assessed at Day 20 after the stent removal
Time frame: up to 90 days (at Day 20 post stent removal)
The severity and incidence of all other adverse events than those mentioned above occurred during the follow-up period were evaluated at Day 20 day after the stent removal.
Taewoong Medical Co., Ltd.
Industry
A Prospective, Multi-center, Single Arm, Non-inferiority, Open-label, Pivotal Study to Evaluate the Effectiveness and Safety of EUS -Guided Transluminal Drainage With 'Niti-S SPAXUS Stent' for the Treatment of Pancreatic Pseudocyst
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02845258
Cysts, Digestive System Diseases
Gothenburg, Sweden
View Trial DetailsNCT03147768
Adenocarcinoma, Adenoma
Houston, Texas, United States
View Trial DetailsNCT03797209
Cysts, Digestive System Diseases
Nagakute-Shi, Aichi-ken, Japan
View Trial DetailsNCT03002051
Acute Cholecystitis, Biliary Obstruction
Hong Kong, China
View Trial Details