NCT Number: NCT01130974

A Study to Assess the Safety and Efficacy of a Daily Disposable Contact Lens

The objective of this study is to evaluate the safety and efficacy of the Bausch & Lomb daily disposable tint contact lens (Test) compared to a currently marketed daily disposable cosmetic tint contact lens (Control).

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Bausch & Lomb

Rochester, New York, 14609, United States

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subjects must have clear central corneas and be free of any anterior segment disorders.
  • Subjects must be adapted wearers of soft contact lenses, wear a lens in each eye, and each lens must be of the same manufacture and brand.
  • Subjects must be correctable through spherocylindrical refraction to 32 letters (0.3 logMAR) or better (distance, high contrast) in each eye.
  • Subjects must be of Asian descent.
  • Subjects must require plano or myopic correction and must require contact lens correction from plano to -6.00 D in both eyes.

Exclusion criteria

  • Subjects who have any systemic disease affecting ocular health.
  • Subjects using any systemic or topical medications that will, in the Investigator's opinion, affect ocular physiology or lens performance.
  • Subjects with an active ocular disease or are using any ocular medication.
  • Subjects with any "Present" finding during the slit lamp examination that, in the Investigator's judgment, interferes with contact lens wear.
  • Subjects with any scar or neovascularization within the central 4 mm of the cornea. Subjects with minor peripheral corneal scarring (that does not extend into the central area), that in the Investigator's judgment, does not interfere with contact lens wear, are eligible for this study.
  • Subjects who currently wear monovision, multifocal, or toric contact lenses.
  • Subjects who are adapted wearers of 1-Day Acuvue Define daily disposable cosmetic tint contact lenses.

Treatment and study plan

Bausch & Lomb contact lens

Device

Bausch & Lomb daily disposable cosmetic tint contact lens

Marketed daily disposable contact lens

Device

Marketed daily disposable cosmetic tint contact lens

Primary outcomes

  1. Slit Lamp Findings

    Time frame: Summarized over all follow-up visits through 1 month

    Graded Slit lamp findings (epithelial edema, epithelial microcysts, corneal staining, limbal injection, bulbar injection, upper lid tarsal conjunctival abnormalities, corneal neovascularization, and corneal infiltrates) > grade 2 over all follow-up visits, summarizes the worst case over all follow-up visits. Graded 0-4 with 0=none and 4=severe

  2. logMAR Visual Acuity (VA)

    Time frame: Summarized over all visits, and dispensed visit

    Non-inferiority of distance high contrast logMAR lens VA. A negative value indicates improved VA. Lens VA was established for All Study, Dispensed, 2-Week Follow-up Visit, and 1-Month Follow-up Visit

  3. logMAR Visual Acuity (VA)

    Time frame: 2 week and 1 month follow-up

    Non-inferiority of distance high contrast logMAR lens VA. A negative value indicates improved VA. Lens VA was established for All Study, Dispensed, 2-Week Follow-up Visit, and 1-Month Follow-up Visit

Secondary outcomes

  1. Lens Wettability

    Time frame: Summarized over all follow-up visits through 1 month

    Lens wettability was rated as Grade 4-0. Grade 4 = 100% of anterior surface wettable (optimal); Grade 3 = presence of small (< 0.1 mm), individual, discrete non-wetting areas (slight); Grade 2 = presence of single area of non-wetting between 0.1 mm and 0.5 mm in size (mild); Grade 1 = presence of several areas on non-wetting, each between 0.1 mm and 0.5 mm in size (moderate); Grade 0 = presence of one or more non-wetting areas > 0.5 mm in size (severe). Suboptimal lens wettability was defined as a rating other than Grade 4, ie slight, mild, moderate, or severe ratings. Over All Visits summarizes the worst case over the dispensing and all follow-up visits.

  2. Lens Deposits

    Time frame: Summarized over all follow-up visits through one month

    Degree of lens deposits was assessed as none, light, medium, or heavy. Suboptimal lens deposits were defined as a degree rating of medium or heavy. Measured over all visits through one month

  3. Lens Centration

    Time frame: Summarized over all follow-up visits through 1 month

    Lens centration was assessed as excellent(fully centered), good (slight decentration, no corneal exposure), fair (decentration, intermittent corneal exposure), or poor (incomplete corneal coverage and/or edge lift).

    Suboptimal lens centration was defined as a rating other than excellent.

  4. Lens Movement

    Time frame: Summarized over all follow-up visits through one month

    Lens movement was assessed as adequate, excessive (> 0.6 mm), insufficient (< 0.2 mm), or adherence. Suboptimal lens movement was defined as a rating other than adequate.

  5. Symptoms & Complaints

    Time frame: Summarized over all follow-up visits through one month

    Subject symptoms/complaints were assessed on a scale from 0 to 100, with 0 denoting least favorable symptoms/complaints and 100 being the most favorable score.

Sponsors and collaborators

Lead sponsor

Bausch & Lomb Incorporated

Industry

Registry information

Important dates

Study start
2010
Primary completion
2010
Study completion
2010
First posted
May 26, 2010
Registry last updated
Dec 10, 2013

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.