The study population will consist of healthy subjects who meet the FDA, AABB, and site-specific research donor eligibility criteria for an apheresis platelet collection.
Apheresis platelets (single or double) will be collected in 100% plasma on the Trima Accel® Automated Blood Collection system. Each study apheresis collection will be processed using the INTERCEPT Blood System for Platelets; apheresis platelets containing a platelet dose of 4.0 to 5.2 x10^11 platelets in 300 to 390 mL of plasma will be processed using the INTERCEPT Large Volume (LV) processing set. The INTERCEPT process will begin on either the day of collection (Day 0) or the day following collection (Day 1); illumination on the LED Illuminator must occur within 24 hours after the end of collection. Test platelet components will be stored for up to 5 days, after collection, in 100% plasma. In vitro platelet function will be evaluated on pre-treatment (Day 0/1), at the end of INTERCEPT treatment (Day 1/2), and at end of storage (Day 5).
At the end of storage, an aliquot of Test platelets will be aseptically removed from each subject's INTERCEPT platelet storage container and prepared for radiolabeling using Variant 1 BEST version 4.2.1 (Variant 1) method. Variant 1 method does not incorporate an initial soft spin in the presence of ACD A described in the BEST 4.2.1 method which results in improved in vitro platelet recovery and quality during preparation for radiolabeling compared to the BEST procedure. The method for collection and radiolabeling of the fresh Control platelets in Variant 1 of BEST 4.2.1 contains the same steps as published in the BEST 4.2.1 method (BEST).
The recovery and survival for Test platelets will be compared against the fresh platelet Control. Recovery and survival of INTERCEPT platelets will be assessed after 5 days of storage for up to 24 evaluable subjects.
Test and Control platelets will be randomly radiolabeled with either 51Cr as sodium chromate (Na251CrO4) or 111In as Indium Oxine, depending upon randomization. Subjects will be randomized with equal probability to the radiolabeling sequences (111In/51Cr vs. 51Cr/111In) for Test INTERCEPT platelets/Control fresh platelets. After radiolabeling, the autologous Control and Test platelet samples will be simultaneously infused into the subject.
Blood samples will be drawn immediately before infusion and for radioactivity measurements at 2 hours ±15 min post-infusion (Day 0), and 6 more samples will be drawn at 1 (within ±4 hours from time of infusion), 2, 3, 5±1, 7/8, and 11±1 days post-infusion (DPI)). The exact time of each sample draw will be recorded.
Subjects will be monitored for safety (adverse events including transfusion reactions) from the time of the apheresis procedure until 24 hours after the last DPI blood sample is drawn.