Therasphere
DevicePatients will receive a single administration of Yttrium-90 glass microspheres (TheraSphere) delivered via selective catheterization of the splenic artery as part of a Selective Internal Radiation Therapy (SIRT) procedure.
The treatment is performed by interventional radiology using a femoral or brachial arterial approach, followed by intra-arterial infusion of the microsphere through a microcatheter positioned in the splenic arterial branches.
A dose-escalation scheme is applied with three planned absorbed dose levels (100Gy, 150 Gy and 200 Gy) to determine the maximum tolerated dose (MTD). The administrated activity is calculated based on splenic volume and vascular anatomy assessed during pre-treatment imaging.
TheraSphere is administered once on Day 1, with no repeat dosing. Patients undergo post-procedural imaging and are followed for safety, efficacy and dosimetry outcomes.