Regadenoson
DrugAdministered by intravenous bolus.
Other names: CVT 3146, Lexiscan
NCT Number: NCT01334918
The purpose of this study is to compare Multidetector Computed Tomography (MDCT) and Single Photon Emission Computed Tomography (SPECT) stress myocardial perfusion imaging (MPI) with regadenoson in order to detect the presence or absence of reversible defects.
Looking for future studies?
Notify Me45 year and older
All sexes
Interventional
Phase 2
Sutter Roseville Medical Center, Roseville, California, United States
All participants will be randomized to one of two imaging sequences: rest/stress SPECT on Day 1 followed by stress/rest MDCT on Day 2 or stress/rest MDCT on Day 1 followed by rest/stress SPECT on Day 2. All stress scans will involve the injection of regadenoson as the pharmacologic stress agent.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Administered by intravenous bolus.
Other names: CVT 3146, Lexiscan
Administered by intravenous infusion
Other names: Cardiolite, Myoview
Administered by intravenous infusion.
Procedure/Surgery
Procedure/Surgery
Time frame: Day 1 and Day 2
The number of reversible defects categorized into absence or presence of ischemia (0-1 versus ≥2), as assessed by the central imaging laboratory for both SPECT and MDCT. The 17-segment model for standardized myocardial segmentation was used for myocardial perfusion readings for SPECT and MDCT. At rest and stress, each segment was scored on a 0 to 4 scale according to the amount of contrast or radiotracer the myocardium in the segment absorbed: -0: normal perfusion -1: slightly reduced contrast/radiotracer uptake -2: moderately reduced contrast/radiotracer uptake -3: severely reduced contrast/radiotracer uptake -4: absent contrast/radiotracer uptake. The median score from the 3 blinded readers for each segment was used. If the stress score was ≥ 2 and the rest score was less than the stress score, the segment was counted as having a reversible defect. A participant was classified as ischemic in the presence of 2 or more segments with reversible defects, excluding segment 17.
Time frame: Day 1 and Day 2
Overall image quality was assessed by three independent blinded readers for each modality (single photon emission computed tomography (SPECT) and multidetector computed tomography (MDCT)). Image quality was rated on a 4-point scale as either excellent, good, fair or poor at rest using SPECT and MDCT and under stress using regadenoson SPECT and regadenoson stress computed tomography perfusion (CTP).
Time frame: Day 1 and Day 2
The number of reversible defects in the LAD categorized into absence or presence of ischemia (0-1 versus ≥2), as assessed by the central imaging laboratory for both SPECT and MDCT. The 17-segment model for standardized myocardial segmentation was used for myocardial perfusion readings for SPECT and MDCT. At rest and stress, each segment was scored on a 0 to 4 scale according to the amount of contrast or radiotracer the myocardium in the segment absorbed: -0: normal perfusion -1: slightly reduced contrast/radiotracer uptake -2: moderately reduced contrast/radiotracer uptake -3: severely reduced contrast/radiotracer uptake -4: absent contrast/radiotracer uptake. The median score from 3 blinded readers for each segment was used. If the stress score was ≥ 2 and the rest score was less than the stress score, the segment was counted as having a reversible defect. A participant was classified as ischemic in the presence of ≥ 2 segments with reversible defects, excluding segment 17.
Time frame: Day 1 and Day 2
The number of reversible defects in the RCA categorized into absence or presence of ischemia (0-1 versus ≥2), as assessed by the central imaging laboratory for both SPECT and MDCT. The 17-segment model for standardized myocardial segmentation was used for myocardial perfusion readings for SPECT and MDCT. At rest and stress, each segment was scored on a 0 to 4 scale according to the amount of contrast or radiotracer the myocardium in the segment absorbed: -0: normal perfusion -1: slightly reduced contrast/radiotracer uptake -2: moderately reduced contrast/radiotracer uptake -3: severely reduced contrast/radiotracer uptake -4: absent contrast/radiotracer uptake. The median score from 3 blinded readers for each segment was used. If the stress score was ≥ 2 and the rest score was less than the stress score, the segment was counted as having a reversible defect. A participant was classified as ischemic in the presence of ≥ 2 segments with reversible defects, excluding segment 17.
Time frame: Day 1 and Day 2
The number of reversible defects in the LCX categorized into absence or presence of ischemia (0-1 versus ≥2), as assessed by the central imaging laboratory for both SPECT and MDCT. The 17-segment model for standardized myocardial segmentation was used for myocardial perfusion readings for SPECT and MDCT. At rest and stress, each segment was scored on a 0 to 4 scale according to the amount of contrast or radiotracer the myocardium in the segment absorbed: -0: normal perfusion -1: slightly reduced contrast/radiotracer uptake -2: moderately reduced contrast/radiotracer uptake -3: severely reduced contrast/radiotracer uptake -4: absent contrast/radiotracer uptake. The median score from 3 blinded readers for each segment was used. If the stress score was ≥ 2 and the rest score was less than the stress score, the segment was counted as having a reversible defect. A participant was classified as ischemic in the presence of ≥ 2 segments with reversible defects, excluding segment 17.
Time frame: Day 1 and Day 2
Using the 17-segment scoring system, a segment scored above 1 (i.e., 2 to 4) and equal at rest and stress was counted as having a fixed defect. At rest and stress, each segment was scored on a 0 to 4 scale according to the amount of contrast or radiotracer the myocardium in the segment absorbed: -0: normal perfusion -1: slightly reduced contrast/radiotracer uptake -2: moderately reduced contrast/radiotracer uptake -3: severely reduced contrast/radiotracer uptake -4: absent contrast/radiotracer uptake.
Time frame: Day 1 and Day 2
Using SPECT as the reference standard, the false negative percentage was calculated as the percentage of participants with two or more ischemic segments on SPECT, but less on CT.
Astellas Pharma Inc
Industry
A Phase 2, Open-Label, Randomized, Cross-Over Study of Regadenoson in Subjects Undergoing Stress Myocardial Perfusion Imaging by Multidetector Computed Tomography (MDCT) and Single Photon Emission Computed Tomography (SPECT)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00826280
Arterial Occlusive Diseases, Arteriosclerosis
Birmingham, Alabama, United States
View Trial DetailsNCT00265525
Arterial Occlusive Diseases, Arteriosclerosis
London, Ontario, Canada
View Trial DetailsNCT07473596
Arterial Occlusive Diseases, Arteriosclerosis
Helsinki, Uusimaa, Finland
View Trial DetailsNCT05292092
Arterial Occlusive Diseases, Arteriosclerosis
Algeciras, Spain
View Trial Details